CHRZAN K L,STEC C,FARZANEH M. Probes for spot measurement of surface conductivity on polluted insulators[J]. IET Sci.Meas. Technol,2007,1(5):295-300.
[4]
SUNDARARAJAN R. Effect of insulator profiles on DC flash-over voltage under polluted conditions[J]. IEEE Transac-tions on Dielectrics and Electrical Insulations,1994,1(1):124-132.
[5]
SUN Baoqiang,WANG Liming,GUAN Zhicheng. The compa-rative study of overall and partial surface conductivity method[J]. IEEE Trans.on Dielectrics and Electrical Insulation,2011,6(6):225-255.
[6]
蔡 伟,李 敏,杨颜红. 污秽绝缘子在线监测系统的设计与实现[J]. 电力系统自动化,2002,26(17):45-48. CAI Wei,LI Min,YANG Yanhong. On-line monitoring system for polluted insulator based on telemetry[J]. Auto-mation of Electric Power Systems,2002,26(17):45-48.
[7]
徐击水,张子蓬,王淑青,等. 基于GNBR算法的BP网络对绝缘子运行状态预测研究[J]. 电网与清洁能源,2013,29(6):6-9. XU Jishui,ZHANG Zipeng,WANG Shuqing,et al. Rese-arch on the prediction for the operating state of insulators using BP network based on GNBR algorithm[J]. Power System and Clean Energy,2013,29(6):6-9.
[8]
ARAI N. AC fog withstand test on contaminated insulators by steam fog[J]. IEEE Trans. on Power Apparatus and Systems,1982(PAS-101):4316-4323.
[9]
WYK L V,HOLTZHAUSEN J P,VOSLOO W L. Surface con-ductivity as an indication of the surface condition of non-ceramic insulators[J]. IEEE AFRICON 4th,1996(1):485-488.
[10]
GB/T 4585―2004 交流系统用高压绝缘子的人工污秽试验[S]. 2004. GB/T 4585―2004 Artificial pollution tests on high voltage insulators to be used on AC systems[S]. 2004.
[11]
IEC 60507―1991 Artificial pollution tests on high voltage insulators to be used on AC systems[S]. 1991.
[12]
ZHOU J G,DONG G,IMAKOMA T,et al. Contamination performance of outer-rib type suspension insulators[C]//IEEE/PES Transmission and Distribution Conference and Exhibition 2002.Asia Pacific,Yokohama Japan:IEEE/PES, 2002:2185-2190.
[13]
徐 涛,吴光亚,周文俊. 交流特高压输电线路绝缘子串污秽耐压特性试验[J]. 高电压技术,2007,33(7):9-13. XU Tao,WU Guangya,ZHOU Wenjun. Withstand pollution characteristic test of UHV AC transmission line insulator string[J]. High Voltage Engineering,2007,33(7):9-13.
[14]
李恒真,王颖凯,刘 刚,等. 电力外绝缘污秽颗粒等效模型和粒径分布探讨[J]. 电瓷避雷器,2013(1):34-38. LI Hengzhen,WANG Yingkai,LIU Gang,et al. Discussing about the equivalent model and particles size distribution of pollution prticles of power system external insulation[J]. Insulators and Surge Arresters,2013(1):34-38.
[15]
廖青华,吕 ?,唐林权. 基于灰靶理论的高压绝缘子污秽状态综合评判[J]. 电瓷避雷器2012(3):9-14. LIAO Qinghua,LYU Yan,TANG Linquan. Synthetic evalu-ation of high voltage insulator pollution state based on grey target theory[J]. Insulators and Surge Arresters,2012(3):9-14.
[16]
NATIO K,MATSUOKO R,SAKANISHI K. Investigation for the insulation performance of the insulator covered with ice[J]. IEEE Trans. on Power Delivery,1991,6(3):1634-1640.
[17]
AL-HAMOUDI I Y. Performance of high voltage insulators under heavy natural pollution conditions[C]//Proceedings of the 7th International Conference on Transmission and Distribution Construction and Live Line Maintenance.[S.l.]:[s.n.],1995:25-31.
[18]
SCHWARDT W H,HOLTZHAUSEN J P,VOSLOO W L. A comparison between measured leakage current and surface conductivity during salt fog tests[C]//7th AFRICON Confe-rence in Africa. [S.l.]:IEEE,2004:597-600.