BAKER P C,JUDD M D,McARTHUR S D J. A frequency-based RF partial discharge detector for low-power wireless sensing[J]. IEEE Transaction on Dielectrics and Electrical Insulation,2010,17(1):133-140.
[2]
RUDD S,McARTHUR S D J,JUDD M D. A generic knowledge-based approach to the analysis of partial discharge data[J]. IEEE Transaction on Dielectrics and Electrical Insulation,2010,17(1):149-156.
[3]
REID A J,JUDD M D,HEPBURN D M. Simultaneous meas-urement of partial discharges using IEC 60270 and radio-frequency techniques[J]. IEEE Transaction on Dielectrics and Electrical Insulation,2011,18(2):444-455.
[4]
PEARSON J S,FARISH O,HAMPTON B F, et al. Partial discharge diagnostics for gas insulated substations[J]. IEEE Transaction on Dielectrics and Electrical Insulation,1995,2(2):893-905.
[5]
SHIBUYA Y,MATSUMOTO S,TANAKA M. Electromag-netic waves from partial discharges and their detection using patch antenna[J]. IEEE Transaction on Dielectrics and Electrical Insulation,2010,17(3):862-871.
[6]
HIKITA M,OHTSUKA S,MARUYAMA S. Influence of disconnecting part on propagation properties of PD-induced electromagnetic wave in model GIS[J]. IEEE Transaction on Dielectrics and Electrical Insulation,2010,17(6):1731-1737.
[7]
齐 波,李成榕,耿弼博,等. GIS设备绝缘子高压电极故障局部放电严重程度的诊断与评估[J]. 高电压技术,2011,37(7):1719-1727. QI Bo,LI Chengrong,GENG Bibo,et al. Severity diagnosis and assessment of the partial discharge provoked by high-voltage electrode defect on GIS insulator surface[J]. High Voltage Engineering,2011,37(7):1719-1727.
[8]
齐 波,李成榕,郝 震,等. GIS绝缘子表面固定金属颗粒沿面局部放电发展的现象及特征[J]. 中国电机工程学报,2011,31(1):101-108. QI Bo,LI Chengrong,HAO Zhen,et al. Evolution pheno-mena and features of surface partial discharge initiatedby immobilized metal particles on GIS insulators[J]. Procee-dings of the CSEE,2011,31(1):101-108.
[9]
REID A J,JUDD M D,STEWART B G,et al. Identification of multiple defects in solid insulation using combined RF and IEC 60270 PD measurement[C]//Proc.9th IEEE International Conference on Solid Dielectrics.Winchester,UK: IEEE,2007:585-588.
[10]
CLEARY G P,JUDD M D. UHF and current pulse measure-ments of partial discharge activity in mineral oil[J]. IEE Proceedings Science,Measurement and Technology,2006,153(2):47-54.
[11]
REID A J,JUDD M D,FOURACRE R A. Identification of simultaneously active partial discharge sources using combined radio frequency and IEC 60270 measurement[J]. IEE Proc.Science,Measurement and Technology, 2011,158(5):102-108.
[12]
YOSHIDA M,KOJIMA H,HAYAKAWA N,et al. Evaluation of UHF method for partial discharge measurement by simultaneous observation of UHF signal[J]. IEEE Transa-ction on Dielectrics and Electrical Insulation,2011,18(2):425-431.
[13]
HOSHINO T,MARUYAMA S,NOJIMA K,et al. A unique sensitivity verification combined with real-time partial-discharge identification method[J]. IEEE Transactions on Power Delivery,2005,20(3):1890-1896.
[14]
HOSHINO T,KOYAMA H,MARUYAMA S,et al. Compa-rison of sensitivity between UHF method and IEC 60270 for onsite calibration in various GIS[J]. IEEE Transactions on Power Delivery,2006,21(4):1948-1953.
[15]
HIKITA M,OHTSUKA S,WADA J,et al. Propagation pro-perties of PD-induced electromagnetic wave in 66 kV GIS model tank with L branch structure[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2011,18(5):1678-1685.