[1] | SUEHIRO J, ZHOU G, HARA M. Detection of partial discharge in SF6 gas using a carbon nanotube-based gas sensor[J]. Sensors and Actuators, 2005, 105(2): 164-169.
|
[2] | BEYER C, JENETT H,,KLOCKOW D. Influence of reactive SFX gases on electrode surfaces after electrical discharges under SF6 atmosphere[J]. IEEE Trans. on Dielectrics and Electrical Insulation, 2000,7(2):234-240.
|
[3] | IEC 60480―2004 Guidelines for the checking and treatment of sulfur hexafluoride(SF6) taken from electrical equipment and specification for its re-use[S].2004.
|
[4] | 中国电力科学研究院. GB/T 8905―1996 六氟化硫电气设备中气体管理和检测导则[S].北京:中国标准出版社,1997. China Electric Power Research Institute.GB/T 8905―1996 The guide for processing and measuring SF6 gas in power apparatus [S].Beijing:China Standard Press,1997.
|
[5] | 颜湘莲,王承玉,季严松,等.开关设备中SF6气体分解产物检测的应用[J]. 电网技术,2010,34(9): 160-165. YAN Xianglian, WANG Chengyu, JI Yansong, et al. Application of decomposition products detection of SF6 in switchgears[J]. Power System Technology,2010,34(9):160-165.
|
[6] | 池立江,颜 语,袁 亮.SF6气体压力对同轴电容电子式电压互感器的影响[J]. 电力电容器与无功补偿,2013, 34(1):61-64. CHI Lijiang, YAN Yu, YUAN Liang. Influence of SF6 gas pressure to coaxial capacitive and electronic voltage transformer[J]. Power Capacitor & Reactive Power Compensation, 2013, 34(1):61-64.
|
[7] | 罗学琛.SF6气体绝缘全封闭组合电器(GIS)[M]. 北京:中国电力出版社,1998. LUO Xuesen. SF6 Gas insulated switchgear(GIS)[M].Beijing: China Electric Power Press, 1998.
|
[8] | PIEMONTESI M, NIEMEYER L. Sorption of SF6 and SF6 decomposition products by activated alumina and molecular sieve 13X[C]//IEEE International Symposium on Electrical Insulation. Montreal, Quebec:IEEE, 1996:828-838.
|
[9] | 裘吟君,刘 岩,陈晓琳,等.SF6气体杂质与潜伏性故障诊断技术研究[J]. 南方电网技术,2009(3): 67-71. QIU Yinjun, LIU Yan, CHEN Xiaolin, et al. Study on SF6 gas impurities and potential faults diagnosis[J]. Southern Power System Technology,2009(3):67-71.
|
[10] | 张仲期,连鸿松.通过检测SO2发现SF6电气设备故障[J]. 中国电力, 2001,34(1):78-81. ZHANG Zhongqi, LIAN Hongsong. Using SO2 detection for failure checking of SF6 electrical equipment[J]. Electric Power, 2001,34(1):78-81.
|
[11] | 王小波,谢开贵.计及开关故障的复杂配电系统可靠性评估[J]. 电网技术,2008,32(19): 16-21. WANG Xiaobo, XIE Kaigui. Reliability evaluation of complex distribution system taking switch faults into account[J]. Power System Technology, 2008,32(19): 16-21.
|
[12] | 刘有为,吴立远,弓艳朋.GIS 设备气体分解物及其影响因素研究[J]. 电网技术,2009,33(5): 58-61. LIU Youwei, WU Liyuan, GONG Yanpeng. Investigation on SF6 decomposition products in GIS and affecting factors[J]. Power System Technology, 2009,33(5): 58-61.
|
[13] | 庄贤盛,李 智,姚唯建,等. SF6电气设备放电故障检测和判断方法[J]. 广东电力,2008,21(12): 35-38. ZHUANG Xiansheng, LI Zhi, YAO Weijian, et al. Detection and judgment of discharge failures of SF6 electrical equipment[J]. Guangdong Electrical Power, 2008,21(12): 35-38.
|
[14] | 刘 佳,朱 华,仝松利,等.气体分析技术在SF6设备内部故障判断中的应用[J]. 河南电力, 2009 (1):32-34. LIU Jia, ZHU Hua, TONG Songli, et al. The application of gas analysis technique on line fault judgment of equipments[J]. Henan Electrical Power, 2009(1): 32-34.
|
[15] | 游荣文,黄逸松.基于SO2、H2S含量测试的SF6电气设备内部故障的诊断[J]. 福建电力与电工, 2004(2):15-16. YOU Rongwen,HUANG Yisong. Diagnosis of internal faults in SF6 electrical equipments based on measuring SO2 and H2S[J]. Fujian Electric and Electrician, 2004(2):15-16.
|
[16] | 毕玉修,卞 超.应用SF6气体分解物进行电气设备故障诊断的探讨[J]. 江苏电机工程, 2007,26(5):14-17. BI Yuxiu, BIAN Chao. Research on electric equipment fault diagnosis applied on SF6 decomposing gases[J].Jiangsu Electrical Engineering, 2007,26(5):14-17.
|
[17] | 郭嫒嫒,刘汉梅,王承玉. SF6高压开关设备运行状态与气体成分关系的研究[R].北京:中国电力科学研究院,2007. GUO Aiai, LIU Hanmei, WANG Chengyu. Research of SF6 high voltage switch equipment operation status and the gas composition relationship[R]. Beijing:China Electric Power Research Institute,2007.
|
[18] | 中国南方电网有限责任公司.Q/CSG 114002―2011 电力设备预防性试验规程[S].2011. China Southern Grid Corporation.Q/CSG 114002―2011 Preventive test code for electric power equipment[S].2011.
|
[19] | 陈晓清,任 明,彭华东,等.GIS设备中SF6气体分解影响因素分析[J]. 电网与清洁能源,2010,26(7):34-38. CHEN Xiaoqing, REN Ming, PENG Huadong, et al. An analysis on affecting factors of SF6 gas decomposition in GIS equipment[J]. Power System and Clean Energy, 2012,28(12):38-41.
|