[1] | 荣命哲,贾申利,王小华. 电器设备在线监测[M]. 北京:机械工业出版社,2007. RONG Mingzhe,JIA Shenli,WANG Xiaohua. Online monitoring of electrical apparatus[M]. Beijing:China Machine Press,2007.
|
[2] | 荣命哲,王小华,王建华. 智能开关电器内涵的新发展探讨[J]. 高压电器,2010,46(5):1-3. RONG Mingzhe,WANG Xiaohua,WANG Jianhua.Disscussion on new development of connotation for intelligent switchgear[J]. High Voltage Apparatus,2010,46(5):1-3.
|
[3] | 李 金,孙 斌,张 静,等. 电能质量监测终端的IEC 61850信息模型[J]. 电网与清洁能源,2013,29(11):20-24. LI Jin,SUN Bin,ZHAGN Jing,et al. An IEC 61850 standard model for power quality supervision terminal[J]. Power System and Clean Energy,2013,29(11):20-24.
|
[4] | 王建华,宋政湘,耿英三,等. 智能电器理论与关键技术研究[J]. 电力设备,2008,9(3):1-4. WANG Jianhua,SONG Zhengxiang,GENG Yingsan,et al. Study on intelligent electrical apparatus and key technology[J]. Electrical Equipment,2008,9(3):1-4.
|
[5] | 周丽丽,方春恩,李 伟,等. 27.5 kV永磁机构真空断路器动作特性仿真与试验研究[J]. 高压电器,2008,44(3):214-216. ZHOU Lili,FANG Chun’en,LI Wei,et al. Simulation and testing of operating characteristic of 27.5 kV vacuum circuit breaker with permanent magnet actuator[J]. High Voltage Apparatus,2008,44(3): 214-216.
|
[6] | 李志兵,许沛丰,刘华伟,等. 断路器电容器介损随电压变化关系研究[J]. 电力电容器,2007,28(6):26-30. LI Zhibing,XU Peifeng,LIU Huawei,et al. Research on dielectric loss variation of circuit-breaker capacitors with voltage[J]. Power Capacitor,2007,28(6):26-30.
|
[7] | 杜彦明,顾霓鸿. 中国电力系统配电开关设备现状及事故情况[J]. 高压电器,2001,37(3):1-5. DU Yanming,GU Nihong. Pesent situation of distribution switchgear in chinese power system and analysis of failures[J]. High Voltage Apparatus,2001,37(3):1-5.
|
[8] | 李 炜,李玉春,高以梅,等. 关于真空断路器电寿命极限开断次数的研究[J]. 高压电器,2007,43(3):222-223. LI Wei,LI Yuchun,GAO Yimei,et al. Research on maximal breaking times for vacuum circuit breaker[J]. High Voltage Apparatus,2007,43(3):222-223.
|
[9] | 高齐利,刘 峰. 断路器辅助保护瞬时跟跳逻辑存在问题分析及改进[J]. 电网与清洁能源,2012,28(9):45-49. GAO Qili,LIU Feng. Analysis and improvement for the instantaneous linkage tripping logic of circuit breaker auxiliary protection[J]. Power System and Clean Energy,2012,28(9):45-49.
|
[10] | 徐靖东. 高压断路器电寿命诊断方法的对比分析[J]. 陕西电力,2013,41(3):56-60. XU Jiangdong. Analysis on high voltage circuit breaker electrical life diagnosis method[J]. Shaanxi Electric Power,2013,41(3):56-60.
|
[11] | 张华赢,杨兰均,李良书,等. 投切电容器组专 用真空断路器性能研究[J]. 电力电容器与无功补偿,2011,32(3):38-44. ZHANG Huaying,YANG Lanjun,LI Liangshu,et al.Study on the performance of special vacuum breaker for switching capacitor banks[J]. Power Capacitor & Reactive Power Compensation,2011,32(3):38-44.
|
[12] | 郭 江,刘亚锦,邹积岩. 面向优化检修的真空断路器状态监测与诊断[J]. 高压电器,2007,43(6):454-456. GUO Jiang,LIU Yajin,ZOU Jiyan. Optimal maintenance oriented condition monitoring and diagnosis of vacuum circuit breaker[J]. High Voltage Apparatus,2007,43(6):454-456.
|
[13] | 王恪典,徐海波. 虚拟样机实验仿真技术及其在真空断路器操动机构中的应用[J]. 高压电器,2003,39(6):1-3. WANG Kedian,XU Haibo. Experimental simulation technology of virtual prototype and its application in the design of operating mechanism of vacuum circuit breaker[J]. High Voltage Apparatus,2003,39(6):1-3.
|
[14] | 彭 搏,肖登明. 断路器电寿命的在线监测[J]. 电网与清洁能源,2012,28(12):38-41. PEMG Bo,XIAO Dengming. Online monitoring of the breaker’s electrical life[J]. Power System and Clean Energy,2012,28(12):38-41.
|
[15] | RONG Mingzhe,LOU Jianyong,LIU Yiying. Static and dynamic analysis for contactor with a new type of permanent magnet actuator[J]. IEICE Trans. on Electronics,2006,89(8):1210-1216.
|
[16] | BASSANI R,CIULLI E,PUCCIO F. Study of conic permanent magnet bearings[J]. Meccanica,2002,36(6):745-754.
|
[17] | 骆 虎,游一民,陈德桂,等. 采用ADAMS与电磁系统的耦合优化永磁机构[J]. 高压电器,2008,44(4):335-337. LUO Hu,YOU Yimin,CHEN Degui,et al. Optimum design of permanent magnet mechanism by coupling ADAMS and electromagnetism system[J]. High Voltage Apparatus,2008,44(4):335-337.
|
[18] | 杨 武,荣命哲,王小华,等. 考虑电动力效应的高压断路器动力学特性仿真分析[J]. 中国电机工程学报,2003,23(5):103-107. YANG Wu,RONG Mingzhe,WANG Xiaohua,et al.Dynamic simulation of high-voltage circuit breaker concerning electrodynamic force[J]. Proceedings of the Chinese Society for Electrical Engineering,2003,23(5): 103-107.
|
[19] | 鞠海林. 12 kV真空断路器永磁机构的改进研究[D]. 沈阳:沈阳工业大学,2012.
|
[20] | 石运强. 永磁式真空断路器操作机构的研究[D]. 成都:西南交通大学,2012.
|
[21] | 张宗伟. VS1型真空断路器合闸线圈烧毁故障处理及对策[J]. 高压电器,2010, 46(5):89-91. ZHANG Zongwei. Fault disposal and countermeasures for VS1-typc vacuum circuit breaker closing coil burn-out[J]. High Voltage Apparatus,2010,46(5):89-91.
|
[22] | 许沛丰,高军委,张予洛,等. 对断路器电容器电容及介损测量预试方法的探讨[J]. 电力电容器,2007,28(4):53-56. XUE Peifeng,GAO Junwei,ZHANG Yuluo,et al.Discussion about the way to measure capacitance and dielectric loss of circuit breaker[J]. Power Capacitor,2007,28(4):53-56.
|
[23] | 张 杰,姜亚军,郭大庆. 12 kV真空断路器双线圈单稳态永磁机构的设计[J]. 高压电器,2010,46(9):34-38. ZHANG Jie,JIANG Yajun,GUO Daqing. Design of the double coils and single stable permanent magnetic actuator used in 12 kV vacuum circuit breaker[J]. High Voltage Apparatus,2010,46(9):34-38.
|
[24] | RONG Mingzhe,WANG Xiaohua,YANG Wu. Theoretical and experimental analyses of the mechanical characteristics of a medium-voltage circuit breaker[J]. IEE Proceedings-Science,Measurement and Technology,2005(152):45-49.
|
[25] | RONG Mingzhe,WANG Xiaohua,YANG Wu. Mechanical condition recognition of midium-voltage vacuum circuit breaker based on mechanism dynamic features simulation and ANN[J]. IEEE Transactions on Power Delivery,2005,20(3):1904-1909.
|
[26] | 王小华. 真空断路器机械状态在线识别方法的研究[D].西安:西安交通大学,2006.
|