[1] | 李福寿.中性点非有效接地电网的运行[M]. 北京:水利电力出版社,1993. LI Fushou. Neutral point of effective operation of the grounding grid[M]. Beijing: Water Conservancy Electric Power Press, 1993.
|
[2] | 张纬钹,高玉明.电力系统过电压与绝缘配合[M]. 北京:清华大学出版社,1987. ZHANG Weibo, GAO Yuming. Power system over-voltage and insulation coordination[M]. Beijing: Tsinghua University Press, 1987.
|
[3] | 王晓彤,施 围,刘文泉.改进电气几何模型计算输电线路绕击率[J]. 高电压技术,1998, 24(1):85-87. WANG Xiaotong, SHI Wei, LIU Wenquan. Improve the electrical geometry model transmission lines around rate[J]. High Voltage Engineering, 1998, 24(1): 85-87.
|
[4] | 王东烨,王明策,李连富.220 kV线路防雷技术探讨[J].东北电力技术,2003(6):1-3. WANG Dongye, WANG Mingce, LI Lianfu. 220 kV line lightning protection technology discussed in this paper[J]. Northeast Electric Power Technology, 2003(6): 1-3.
|
[5] | 罗大强,许志荣,唐 军,等.根据历史跳闸记录对10 kV配电线路防雷现状和问题的分析[J]. 电瓷避雷器,2012(2):40-45. LUO Dajiang, XU Zhirong, TANG Jun, et al. Present situation and problems analysis for lightning protection of 10 kV power distribution line based on historical trip records[J]. Insulators and Surge Arresters, 2012(2): 40-45.
|
[6] | 孙 萍.新杭线Ⅰ回路雷击闪络跳闸分析及绕击率、跳闸率的实测计算[J]. 浙江电力,1997(3):16-20. SUN Ping. Xinhang line Ⅰ lightning flashover trip circuit analysis and around, tripping rate measured calculation[J]. Zhejiang Electric Power. 1997(3):16-20.
|
[7] | 张 鑫,邓 鹏,徐 鹏,等10 kV架空绝缘导线雷击断线原因机理分析及防护措施[J]. 电瓷避雷器,2012(1):65-69. ZHANG Xin, DENG Peng, XU Peng, et al. Mechanism analysis and protective measures on the lightning break reason of 10 kV overhead insulation conductor[J]. Insulators and Surge Arresters, 2012(1): 65-69.
|
[8] | WATANABE Y. Influence of preexisting DC voltage on switching surge flashover characteristics[J]. IEEE Trans. on Power Apparatus and Systems, 1968, 87(4): 964-969.
|
[9] | SALAM M A, SALEH U,LATIF A A.Simulation of energized franklin rods for lightning protection[J]. IEEE Trans. on Industry Applications, 1997 (3393): 651-659.
|
[10] | ALLEN N L, GOURGOULIS D E. Effects of negative direct voltage pre-stressing on the breakdown of conductor-rod gaps under positive impulse voltages[J]. IEE Proceedings Science,Measurement and Technology, 1998, 145(3): 105-109.
|
[11] | LI Zhizhao, ZENG Rong, YU Zhanqing. Research on the upward leader emerging from transmission line by simulation experiments[C]//7th Asia-Pacific International Conference on Lightning.[S.l.]:IEEE,2011: 555-558.
|
[12] | BECERRA M, COORAY V. A self-consistent upward leader propagation model[J]. J. Phys. D:Applied Physics, 2006, 39(16): 3708-3715.
|
[13] | BECERRA M, COORAY V. Laboratory experiments cannot be utilized to justify the action of early streamer emission terminals[J]. Journal of Physics D-Applied Physics, 2008, 41(8): 41-47.
|
[14] | GOELIAN N,LALANDE P,BONDIOU A,et al.A simplified model for the simulation of positive-spark development in long air gaps[J]. Journal of Physics D:Applied Physics,1997,30(27):2441-2452.
|
[15] | GALLIMBERT I.The mechanism of long spark formation[J]. Physique Coll.,1972,V40(C7):193-250.
|
[16] | 廖蔚明,崔国华,孙昭英,等.±800 kV直流线路杆塔塔头空气间隙的直流叠加操作冲击放电特性[J]. 电网技术,2008, 32(9):6-9. LIAO Weiming, CUI Guohua, SUN Zhaoying, et al. ±800 kV DC superposition of DC line tower air clearance of tower head impact operating discharge properties[J]. Power System Technology, 2008, 32(9): 6-9.
|
[17] | 王黎明,毛苏春,关志成.板-针间隙在交直流预电压作用下的冲击特性[J]. 清华大学学报,2002, 42(3):285-287. WANG Liming, MAO Suchun, GUAN Zhicheng. Plate-needle clearance in advance AC/DC voltage under the action of impact properties[J]. Journal of Tsinghua University, 2002, 42(3): 285-287.
|
[18] | LIU Q, WANG Z D. Secondary reverse streamer observed in an ester insulating liquid under negative impulse voltage[J]. Journal of Physics D:Applied Physics, 2011,44(40): 2276-2283.
|
[19] | 杨 波,王黎明,关志成,等.交直流预电压下导线-针间隙的冲击特性[J]. 清华大学学报,2002, 42(S1):49-51. YANG Bo, WANG Liming, GUAN Zhicheng, et al. AC/DC voltages wire in advance impact properties of the needle clearance[J]. Journal of Tsinghua University, 2002, 42(S1): 49-51.
|
[20] | 曲振旭,王巨丰,苏浩益,等.特快速暂态过电压下避雷器模型的研究与应用[J]. 电瓷避雷器,2012(2):51-56. QU Zhenxu, WANG Jufeng, SU Haoyi, et al. Application and research on surge arrester models under very fast transient overvoltage[J]. Insulators and Surge Arresters, 2012(2): 51-56.
|
[21] | 蒋兴良,王 军,胡建林,等.1 m 针-板空气间隙正极性操作冲击放电特性及电压校正[J]. 中国电机工程学报,2006,26(16):137-143. JIANG Xingliang,WANG Jun,HU Jianlin,et al.1 m needle-normal polarity operation impact plate air gap discharge characteristic and voltage correction[J]. Proceedings of the CSEE, 2006,26(16):137-143.
|
[22] | 林盛强,林 宏,王巨丰.高速气流灭弧防雷间隙建弧模型的研究[J]. 电瓷避雷器,2012(2):57-61. LIN Shengqiang, LIN Hong, WANG Jufeng. Study on model of constructing arc about parallel gap lightning protection device with arc-extinguished by high-speed airflow[J]. Insulators and Surge Arresters, 2012(2): 57-61.
|
[23] | 殷 勤,郭 洁,严 强,等.外绝缘放电电压校正方法的分析与比较[J]. 电瓷避雷器, 2011(4):9-13. YIN Qin, GUO Jie, YAN Qiang, et al. Analysis and comparison to correction methods of discharge voltage of external insulation[J]. Insulators and Surge Arresters, 2011(4): 9-13.
|
[24] | GRANT I S. A simplified method for estimating lightning performance of transmission lines[J]. IEEE Transactions on Power Delivery, 1985, 104(4): 919-932.
|
[25] | IEEE Working Group.Estimating lightning performance of transmission lines Ⅱ-Updates to analytical models[J]. IEEE Transactions on Power Delivery,1993, 8(3):1254-1267.
|
[26] | 维列夏金,吴维韩.俄罗斯超高压和特高压输电线路防雷运行经验分析[J]. 高电压技术,1998, 24(2):76-79. WEI Liexiajin, WU Weihan. The analysis of lightning protection for EHV and UHV transmission lines in rusia[J]. High Voltage Engineering, 1998, 24(2): 76-79.
|