[1] | WESTER F J,GULSKI E,SMIT J J. Detection of partial discharges at different AC voltage stresses in power cables[J]. IEEE Electrical Insulation Magazine,2007,23(4):28-43.
|
[2] | PETZOLD F,SCHLAPP H,GULSKI E,et al. Advanced solution for on-site diagnosis of distribution power cables[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2008,15(6):1584-1589.
|
[3] | 唐正森,李景禄,李志娟. 10 kV交联电缆接头施工工艺分析及改进措施[J]. 绝缘材料,2009,42(2):71-74. TANG Zhengsen,LI Jinglu,LI Zhijuan. Analysis of test on insulation of high-voltage on site[J]. Insulating Materials, 2009,42(2):71-74.
|
[4] | 张 皓,唐嘉婷,张立志,等. 振荡波测试系统在电缆局放测试定位中的典型案例分析[J]. 电力设备,2008,9(12):31-34. ZHANG Hao,TANG Jiating,ZHANG Lizhi,et al. Typical case analysis of oscillating wave test system in cable partial discharge test and localization in power cable[J]. Electrical Equipment,2008,9(12):31-34.
|
[5] | 陶诗洋. 基于振荡波测试系统的XLPE电缆局部放电检测技术[J]. 中国电力,2009,42(1):98-101. TAO Shiyang. PD detection technique in XLPE power cables based on oscillating wave test system[J]. Electric Power,2009,42(1):98-101.
|
[6] | 夏 荣,赵健康,欧阳本红,等. 阻尼振荡波电压下110 kV交联电缆绝缘性能检测[J]. 高电压技术,2010,36(7):1753-1760. XIA Rong,ZHAO Jiankang,OUYANG Benhong,et al. Dielectric property detection of 110 kV XLPE power cables using damped AC voltages[J]. High Voltage Engineering,2010,36(7):1753-1760.
|
[7] | MAZZETTI C,MASCIOLI F M F,BALDINI F,et al. Partial discharge pattern recognition by neuro-fuzzy networks in heat-shrinkable joints and terminations of XLPE insulated distribution cables[J]. IEEE Transactions on Power Delivery,2006(21):1035-1044.
|
[8] | SAHOO N C,SALAMA M,BARTNIKAS R. Trends in partial discharge pattern classification: A survey[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2005,12(2):248-264.
|
[9] | NIEMEYER L. A generalized approach to partial discharge modeling[J]. IEEE Transactions on Dielectrics and Electrical Insulation,1995,2(4):510-528.
|
[10] | GUTFLEISCH F,NIEMEYER L. Measurement and simulation of PD in epoxy voids[J]. IEEE Transactions on Dielectrics and Electrical Insulation,1995,2(5):729-743.
|
[11] | BODEGA R,CAVALLINI A,MORSHUIS P H, et al. The effect of voltage frequency on partial discharge activity[C]//2002 Annual Report Conference on Electrical Insulation and Dielectric Phenomena.[S.l.]:IEEE, 2002: 685-689.
|
[12] | 杜伯学,马宗乐,霍振星,等. 电力电缆技术的发展与研究动向[J]. 高压电器,2010,46(7):100-104. DU Boxue,MA Zongle,HUO Zhenxing,et al. Recent research status of techniques for power cables[J]. High Voltage Apparatus,2010,46(7):100-104.
|
[13] | 吴 倩,刘毅刚. 高压交联聚乙烯电缆绝缘老化及其诊断技术述评[J]. 广东电力,2003,16(4):1-6. WU Qian,LIU Yigang. Comments on HV XLPE cable insulation ageing and its diagnostic techniques[J]. Guangdong Electric Power,2003,16(4):1-6.
|
[14] | 郭灿新,张 丽,钱 勇,等. XLPE电力电缆中局部放电检测及定位技术的研究现状[J]. 高压电器,2009,45(3):56-60. GUO Canxin,ZHANG Li,QIAN Yong,et al. Current status of partial discharge detection and location techniques in XLPE power cable[J]. High Voltage Apparatus,2009,45(3):56-60.
|
[15] | Working Group 21.09. After laying tests on high voltage extruded insulation cable system[J]. Electra,1977(173): 33-41.
|
[16] | 段乃欣,赵中原,邱毓昌,等. XLPE电缆中局部放电脉冲传播特性的实验研究[J]. 高压电器,2002,38(4):16-18. DUAN Naixin,ZHAO Zhongyuan,QIU Yuchang,et al. Experimental study on the propagation characteristics of the PD pulse in XLPE power cable[J]. High Voltage Apparatus,2002,38(4):16-18.
|
[17] | BOGGS. Fundaments of partial discharge in the context of field cable testing[J]. IEEE Electrical Insulation Magazine,2000,16(25):51-56.
|
[18] | 周 涛,曾祥君. 交联聚乙烯电缆局部放电脉冲高灵敏度检测方法研究[J]. 高压电器,2013,49(5):26-30. ZHOU Tao,ZENG Xiangjun. Study on high sensitivity detection of partial discharge pulse in XLPE cable[J]. High Voltage Apparatus,2013,49(5):26-30.
|
[19] | 杨连殿,朱俊栋,孙 福,等. 振荡波电压在XLPE电力电缆检测中的应用[J]. 高电压技术,2006,32(3):27-30. YANG Liandian,ZHU Jundong,SUN Fu,et al. Use of oscillating wave voltage in the measurements of XLPE power cable[J]. High Voltage Engineering,2006,32(3):27-30.
|
[20] | OYEGOKE B,HYVONEN P,ARO M,et al. Selectivity of damped ac (DAC) and VLF voltages in after-laying tests of extruded MV cable systems[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2003,10(5):874-882.
|