[1] | 王 伟.交联聚乙烯绝缘电力电缆技术基础[M]. 西安:西北工业大学出版社,2011. WANG Wei.XLPE insulated cable[M]. Xi’an: Northwestern Polytechnical University Press,2011.
|
[2] | 王昌长,李福祺,高胜友.电力设备的在线监测与故障诊断[M]. 北京:清华大学出版社,2006. WANG Changchang, LI Fuqi, GAO Shengyou.On-line monitoring and diagnosis for power equipment[M]. Beijing:Tsinghua University Press,2006.
|
[3] | 杨连殿,朱俊栋. 振荡波电压在XLPE 电力电缆检测中的应用[J]. 高电压技术, 2006, 32(3): 27-30. YANG Liandian, ZHU Jundong. Use of oscillating wave voltage in the measurements of XLPE power cable[J]. High Voltage Engineering, 2006,32(3):27-30.
|
[4] | 罗俊华. XLPE电力电缆绝缘特性试验方法的研究[D]. 西安:西安交通大学,2003. LUO Junhua. Study on methods of XLPE power cable insulating characteristics tests[D]. Xi’an: Xi’an Jiaotong University, 2003.
|
[5] | YANG J J, ZHANG D M. Partial discharge phenomena due to electrical treeing in XLPE[C]//Conference on Industrial Electronics and Applications.[S.l.]:IEEE, 2006:1-6.
|
[6] | 韦 斌,王 伟,李成榕,等.VHF钳型传感器在线检测110 kV XLPE电缆局放[J]. 高电压技术,2004,20(7):37-39. WEI Bin,WANG Wei,LI Chengrong. Partial discharge on-line detection of 110 kV XLPE cables using VHF clamp current transducer[J]. High Voltage Engineering, 2004,20(7):37-39.
|
[7] | BOGGS S, DENSLEY J. Fundaments of partial discharge in the context of field cable testing[J]. IEEE Electrical Insulation Magazine, 2000, 16(25): 13-18.
|
[8] | 邱昌容,王乃庆.电工设备局部放电及其测试技术[M]. 北京:机械工业出版社,1994. QIU Changrong,WANG Naiqing.Partial discharge and measurment technology of the electrical equipment[M].Beijing:China Machine Press,1994.
|
[9] | CAVALLINI A, MONTANARI G C.A new methodology for the identification of PD in electrical apparatus: properties and applications[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2005,12(2):203-213.
|
[10] | CAVALLINI A, MONTANARI G C. A fuzzy logic algorithm to detect electrical trees in polymeric insulation systems[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2005, 12(6): 1134-1144.
|
[11] | 谢安生, 郑晓泉. XLPE 电缆绝缘中的电树枝结构及其生长特性[J]. 高电压技术,2007, 33(6):168-173. XIE Ansheng, ZHENG Xiaoquan. Structures and propagation characteristics of electrical trees in XLPE cable insulation[J]. High Voltage Engineering, 2007, 33(6):168-173.
|
[12] | MEIJER S, JONGEN R A,GULSKI E, et al. VHF partial discharge detection during after-laying testing of power cables[C]//2007 International Conference on Solid Dielectrics.Winchester, UK:IEEE, 2007: 544-547.
|
[13] | 吴 倩, 刘毅钢, 李熙谋. 高压交联聚乙烯电缆绝缘老化检测技术调研[J]. 电力设备, 2005,6(7): 40-45. WU Qian, LIU Yigang, LI Ximou. Investigation of insulation ageing detection technology for high voltage XLPE cable[J]. Electrical Equipment, 2005,6(7): 40-45.
|
[14] | VAKILIAN M, BLACKBURN T R, JAMES R E, et al. Semiconducting layer as an attractive PD detection sensor of XLPE cables[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2006,13(4): 885-891.
|
[15] | ABOU D M, BULINSKI A, BAMJI S. On-site diagnostic tests on polymer insulated cables using depolarization current measurement[C]//2007 International Conference on Solid Dielectrics.Winchester,UK:IEEE,2007: 725-728.
|
[16] | BROWN M A, CHARMPION J V. An investigation of partial discharge energy dissipation and electrical tree growth in an epoxy resin[C]//2004 International Conference on Solid Dielectrics.Toulouse, France:IEEE, 2004: 5-9.
|
[17] | 杨孝华.交联聚乙烯电力电缆局部放电模式识别的研究[D]. 重庆:重庆大学,2002. YANG Xiaohua. Research on partial discharge pattern recognition of XLPE power cable[D]. Chongqing: Chongqing University,2002.
|
[18] | 朱俊栋, 陈希诚. 电磁耦合传感器在检测XLPE电缆局部放电中的应用[J]. 华北电力技术, 2007(11):47-49. ZHU Jundong, CHEN Xicheng. Application of the electromagnetic coupling sensors in detecting partial discharges in XLPE cable[J]. North China Electric Power,2007(11):47-49.
|
[19] | OHKI Y. Present stage of partial-discharge monitoring technique in after-laying tests for extra-high voltage XLPE cable lines[J]. IEEE Electrical Insulation Magazine, 2000, 16(1): 74-76.
|