全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
高压电器  2015 

基于广义回归神经网络的油纸绝缘变压器的寿命预测

, PP. 125-130

Keywords: 广义回归神经网络,油纸绝缘变压器,寿命预测

Full-Text   Cite this paper   Add to My Lib

Abstract:

文中基于广义回归神经网络(GRNN)技术挖掘数据变化规律,构建了GRNN神经网络预测模型,运用该模型对油纸绝缘变压器进行寿命预测。将变压器绝缘纸老化过程中生成的特征产物如糠醛、CO2和CO的质量分数,以及相关时间参量作为模型输入。将所采集的多组油纸绝缘变压器的测试样本作为基础数据,运用该模型对相应的变压器进行寿命预测。结果表明,模型寿命预测的输出值与实际值基本一致,从而验证了模型的合理性,这对监测绝缘材料老化状态的进一步研究具有现实意义。

References

[1]  廖瑞金,杨丽君,孙才新,等.基于局部放电主成分因子向量的油纸绝缘老化状态统计分析[J]. 中国电机工程学报,2006,26(14):114-119. LIAO Ruijin,YANG Lijun,SUN Caixin,et al.Aging condition assessment of oil-paper based on principal component and factor analysis of partial diacharge[J]. Proceedings of the CSEE,2006,26(14):114-119.
[2]  刘 敏.不同含水量对油纸绝缘老化速率的影响[J]. 绝缘材料,2008,41(3):40-42. LIU Min. Effect of different moisture content on oil paper insulation aging rate[J]. Insulating Materials,2008,41(3):40-42.
[3]  POOVAMMA P K,AHMED A, VISWANATHA T R,et al. Evaluation of transformer oil by frequency domain technique[C]//2008 IEEE International Conference on Dielectric Liquids.[S.l.]:IEEE,2008:1-4.
[4]  EDMILSON O S,SILV A, SANTANA A M, et al. Determination of degree of polymerization of insulating paper using near infrared spectroscopy and multivariate calibration[J]. Vibrational Spectroscopy,2010,52(2):154-157.
[5]  YAMAGATA N, MIYAGI K, ETSUO O.Diagnosis of thermal degradation for thermally upgraded paper in mineral oil[C]// International Conference on Condition Monitoring and Diagnosis.Beijing, China:[IEEE],2008:21-24.
[6]  王万华. 变压器绝缘老化诊断中应注意的问题[J]. 高电压技术,1995,21(3):79-82. WANG Wanhua. Attention should be paid to the problem of transformer insulation ageing diagnosis[J]. High Voltage Engineering,1995,21(3):79-82.
[7]  SIADA A A,ISLAM S.A new approach to identify power transformer criticality and asset management decision based on dissolved gas-in-oil analysis[J].IEEE Transactions on Dielectrics and Electrical Insulation, 2012,19(3):1007-1012.
[8]  TARKESHWAR H M,JARIAL R K. Make use of DGA to carry out the transformer oil-immersed paper deterioration condition estimation with fuzzy-logic[C]//International Conference on Communication Technology and System Design 2011.[S.l.]:IEEE, 2012:569-576.
[9]  杨启平,薛五德,蓝之达,等.变压器绝缘老化评估技术的研究[J]. 变压器,2006,43(5):1-5. YANG Qiping,XUE Wude,LAN Zhida,et al. Research on aging assessable technique of transformer insulation[J].Transformer,2006,43(5):1-5.
[10]  李公波,徐 刚,沈 杨.变压器循环电流对无功自动补偿装置测量的影响[J]. 电力电容器与无功补偿,2012,33(6);30-32. LI Gongbo,XU Gang,SHEN Yang.Influence of transformer circulating current on reactive power automatic compensation device[J]. Power Capacitor & Reactive Power Compensation,2012,33(6):30-32.
[11]  PERCHERANCIER J P. Fourier transform infrared(FT-IR) spectrometry to detect additives and contaminants in insulating oils[J]. IEEE Trans. on EI,1999,14(3):23.
[12]  SAHA T K. Electrical and chemical diagnostic of transformers insulation-part A: aged transformer sample[J]. IEEE Trans. on PD,1997,12(4): 1547.
[13]  SAHA T K. Electrical and chemical diagnostic of transformers insulation-part B: accelerated aged insulation samples[J]. IEEE Trans. on PD,1997,12(4): 1555.
[14]  AMROLLAHI M H, NAJAFI S Y,REZVANTALAB S, et al. Condition and life assessment of transformers using chemical analysis methods[C]//SPEEDAM 2010- International Symposium on Power Electronics, Electrical Drives, Automation and Motion.[S.l.]:IEEE, 2010:298-302.
[15]  EMSLEY A M. Influence of cellulose degradation on insulation life in power transformers[C]//Proceedings of the International Conference on Cellulose and Cellulose Derivatives: Physico-chemical Aspects and Industrial Applications.[S.l.]:IEEE, 1993:115-124.
[16]  PRADHAN M K,RAMU T S. Criteria for estimation of end of life of power and station transformers in service[C]//Annual Report-conference on Electrical Insulation and Dielectric Phenomena.[S.l.]:CEIDP, 2004:220-223.
[17]  MIRZAIE M, GHOLAMI A,TAYYEBI H.Life time estimation and reliability model for cellulose[C]//Insulation International Conference on Solid Dielectrics.Winchester:[s.n.], 2007:8-13.
[18]  MEMSLEY A,XXIAO R J.Degradation of cellulosic insulation in power transformers[J]. IEE Proc.-Sci. Meas. Technol.,2000,147(3):115-119.
[19]  林朝晖.油浸式电力变压器固体绝缘剩余寿命研究[D].成都:西华大学,2010.
[20]  路长柏. 电力变压器绝缘技术[M]. 哈尔滨: 哈工大出版社,1997.
[21]  DRVENIZA M. Investigations effective methods for assessing the condition of insulation in aged power transformers[J]. IEEE Trans. on PD,1998,13(4): 12-14.
[22]  MORAIS R M. Furfural analysis for assessing degradation of thermally upgraded papers in transformer insulation[J]. IEEE Trans. on D & EI,1999,6(2): 159.
[23]  月冈淑郎.变压器的老化诊断和剩余寿命诊断[J].ソィンテナンス(日),1998(1):12-17.
[24]  刘光源.实用电工手册[K]. 北京:电子工业出版社, 2009.