[1] | DL/T 617―2010 气体绝缘金属封闭开关设备技术条件[S].2010. DL/T 617―2010 Technical conditions for gas insulated metal enclosed switchgear[S].2010.
|
[2] | 卢启付,李兴旺,徐晓刚,等. 基于ANSYS的GIS隔离开关短路事故分析[J]. 高压电器,2012,48(8):76-79. LU Qifu,LI Xingwang,XU Xiaogang,et al. Analysis of short circuit accident’analysis about for GIS isolating switch disconnecting switch based on ANSYS[J]. High Voltage Apparatus,2012,48(8): 76-79.
|
[3] | 卢启付,李兴旺,程养春,等. 一起装配清洁度不够导致的GIS隔离开关短路事故分析[J]. 广东电力,2011,24(11):106-108. LU Qifu,LI Xingwang,CHENG Yangchun,et al. Analysis on short circuit accident of earthing switch of gas insulated metal-enclosed switchgear[J]. Guangdong Electric Power,2011,24(11): 106-108.
|
[4] | 汪晓明,何 萍,刘 衍,等. 一起500 kV HGIS 事故的分析与处理[J]. 高压电器,2014,50(1):129-132. WANG Xiaoming,HE Ping,LIU Yan,et al.Analysis and analysisand treatmentofa 500 kV hybrid gas insulated switchgear accident[J]. High Voltage Apparatus,2014,50(1):129-132.
|
[5] | 徐世山,孟可风,刘文泉. 一起363 kV GIS充电闪络故障的原因分析[J]. 高压电器,2007,43(1):74-76. XU Shishan,MENG Kefeng,LIU Wenquan. Analysis of 363 kV gas insulated switchgear charging flashover fault[J]. High Voltage Apparatus,2007,43(1): 74-76.
|
[6] | 禹化然,蒋伟毅,徐 嵘. 一起220 kV GIS内部短路故障分析[J]. 高压电器,2013,49(8):115-118. YU Huaran,JIANG Weiyi,XU Rong. Analysis of a short circuit fault in a 220 kV gas insulated switchgear[J]. High Voltage Apparatus,2013,49(8):115-118.
|
[7] | 苏 煜,王 薇,张燕涛. 一起GIS三工位隔离开关故障原因分析及处理[J]. 高压电器,2007,43(3):227-228. SU Yu,WANG Wei,ZHANG Yantao. Analysis and treatment of the fault in GIS disconnetor with three positions[J]. High Voltage Apparatus,2007,43(3):227-228.
|
[8] | 王静君,黄瑜珑. 一起500 kV GIS隔离开关绝缘闪络的事故分析[J]. 高压电器,2013,49(9):119-123. WANG Jingjun,HUANG Yulong. Analysis on an insulation breakdown accident of 500 kV GIS disconnector[J]. High Voltage Apparatus,2013,49(9):119-123.
|
[9] | CIGRE Joint Working Group 33/23.12. Insulation coordination of GIS:return of experience,on site tests and diagnostic techniques[C]//International Council on Large Electric System.Paris,France:[s.n.],1998:67-97.
|
[10] | IEC 60071-2―1996 Insulation coordination Part 2:Application guide[S].1996.
|
[11] | 刘 艳,黄松波,何胜红. 一起GIS交接试验过程中的放电情况分析[J]. 高电压技术,2004,30(7):73-74. LIU Yan,HUANG Songbo,HE Shenghong. Analysisof dischargein GIS during commission test[J]. High Voltage Engineering,2004,30(7): 73-74.
|
[12] | 孙 茁,薛 源,郭宏伟. 126 kV GIS设备典型故障分析与处理[J]. 高压电器,2010,46(11):95-98. SUN Zhuo,XUE Yuan,GUO Hongwei. Analysis and solution to a 126 kV GIS equipment fault[J]. High Voltage Apparatus,2010,46(11):95-98.
|
[13] | 王 俊,田刚领,张国跃,等. 悬浮电位引起电场放电的计算分析[J]. 电气开关,2010(5):70-71. WANG Jun,TIAN Gangling,ZHANG Guoyue,et al. The calculation and analysis of the electric field discharge caused by floating potential[J]. Electric Switcher,2010(5): 70-71.
|
[14] | 丁登伟,高文胜,刘卫东. 采用特高频法的GIS典型缺陷特性分析[J]. 高电压技术,2011,37(3):706-710. DING Dengwei,GAO Wensheng,LIU Weidong. Analysis on the typical partial discharge using UHF detection method for GIS[J]. High Voltage Engineering,2011,37(3):706-710.
|
[15] | 李 信,李成榕,李亚莎,等. 有限时域差分法对GIS局部放电传播的分析[J]. 中国电机工程学报,2005,25(17):150-155. LI Xin,LI Chengrong,LI Yasha,et al. Analysis on partial discharge in GIS by FDTD method[J]. Proceedings of the Chinese Society for Electrical Engineering,2005,25(17):150-155.
|
[16] | 张鸣超,王建生,邱毓昌. GIS中局部放电测量用超高频传感器[J]. 电网技术,1998,22(8):42-44. ZHANG Mingchao,WANG Jiansheng,QIU Yuchang. UHF sensors for partial discharge measurement in GIS[J]. Power System Technology,1998,22(8):42-44.
|
[17] | 姚 勇,岳彦峰,黄兴泉. GIS超高频/超声波局放检测方法的现场应用[J]. 高电压技术,2008,34(2):422-424. YAO Yong,YUE Yanfeng,HUANG Xingquan. Field application of UHF and AE method for detecting PD in GIS[J]. High Voltage Engineering,2008,34(2):422-424.
|
[18] | 张 磊,林 群,丁登伟,等. GIS中局部放电特高频信号传播特性的仿真分析[J]. 高电压技术,2011,37(3):726-731. ZHANG Lei,LIN Qun,DING Dengwei,et al. Simulation analysis on the attenuation characteristics of partial discharge ultra-high frequency signals in GIS[J]. High Voltage Engineering,2011,37(3):726-731.
|
[19] | 唐 炬,侍海军,许高峰,等. GIS局部放电两种内置传感器响应特性分析[J]. 高电压技术,2003,29(2):29-31. TANG Ju,SHI Haijun,XU Gaofeng,et al. Two couplers for detection of partial discharge in gas-insulated substations[J]. High Voltage Engineering,2003,29(2):29-31.
|