高压电器  2015 

一种基于相位偏移的自抗扰孤岛检测法在光伏并网逆变系统中的应用

DOI: 10.13296/j.1001-1609.hva.2015.10.003, PP. 13-18

Keywords: 并网逆变器,主动式孤岛检测法,相位偏移,自抗扰,检测盲区

Full-Text   Cite this paper   Add to My Lib

Abstract:

光伏并网逆变器必须具备孤岛检测功能,而传统的孤岛检测法存在检测盲区。文中首先采用品质因数/谐振频率平面法对基于相位偏移的孤岛检测法的检测盲区进行分析。在此基础上,提出了一种基于相位偏移的自抗扰孤岛检测法,该方法通过引入频率控制函数,一方面能够有效地防止系统扰动造成的误判,另一方面有效的减小了检测盲区。此外,文中还给出了自抗扰孤岛孤岛检测法参数选取方案。最后,通过数值仿真验证了不同负载状况下该孤岛检测方法的有效性。

References

[1]  YIN J,CHANG L C,DIDUCH C. Recent developments in islanding detection for distributed power generation[C]// 2004 Large Engineering Systems Conference on Power Engineering.[S.l.]: IEEE,2004:124-128.
[2]  ROPP M E,BEGOVIC M,ROHATGI P. Prevention of islanding in grid-connected photovoltaic systems[J]. Progress in Photovoltaics,1999,7(1): 39-59.
[3]  ROPP M E,BEGOVIC M,ROHATGI A. Analysis and performance assessment of the active frequency drift method of islanding prevention[J]. IEEE Transactions on Energy Conversion,1999,14(3):810-816.
[4]  HUNG G K,CHANG C C,CHEN C L. Automatic phase-shift method for islanding detection of grid-connected photovoltaic inverters[J]. IEEE Transactions on Energy Conversion,2003,18(1):169-173.
[5]  IEEE Std 929―2000 IEEE recommended practice for utility interface of photovoltaic(PV)systems[S].2000.
[6]  LIU F,KANG Y,ZHANG Y,et al. Improved SMS islanding detection method for grid-connected converters[J]. IET Renew Power Generation,2010,4(1): 36-42.
[7]  郭小强,赵清林,邬伟扬. 光伏并网发电系统孤岛检测技术[J]. 电工技术学报,2007, 22(4):157-162. GUO Xiaoqiang,ZHAO Qinglin,WU Weiyang. Islanding detection method for photovoltaic grid-connected power system[J]. Transactions of China Electrotechnical Society,2007,22(4): 157-162.
[8]  ROPP M,AAKER K,HAIGH J,et al. Using power line carrier communications to prevent islanding[C]//Photovoltaic Specialists Conference. Anchorage, AK:IEEE,2000:1675-1678.
[9]  YU B,MATSUI M,JUNG Y,et al. A combined active anti-islanding method for photovoltaic systems[J]. Renewable Energy,2008,33(5):979-985.
[10]  MANGO F,LISERRE M,AQUILA A D,et al. Overview of anti-islanding algorithms for PV systems. Part I: Passive methods[C]//Power Electronics and Motion Control Conference. Portoroz:IEEE,2006:1878-1883.
[11]  MANGO F,LISERRE M,AQUILA A D,et al. Overview of anti-islanding algorithms for PV systems. Part II: Active methods[C]//Power Electronics and Motion Control Conference. Portoroz:IEEE,2006:1884-1889.
[12]  ROPP M E,BEGOVIC M,ROHATGI A,et al. Determining the relative effectiveness of islanding detection methods using phase criteria and nondetection zones[J]. IEEE Transactions on Energy Conversion,2000,15(3):290-296.
[13]  SMITH G A,ONIONS P A,INFIELD D G. Predicting islanding operation of grid connected PV inverters[J]. IEE Proceedings:Electric Power Applications,2000,147(1):1-6.
[14]  刘芙蓉,康 勇,段善旭,等. 一种有效的孤岛检测盲区描述方法[J]. 电工技术学报,2007,22(10):167-172. LIU Furong,KANG Yong,DUAN Shanxu,et al. A novel method for mapping non-detection zone[J]. Transactions of China Electrotechnical Society,2007,22(10):167-172.
[15]  LOPES L C,SUN H L. Performance assessment of active frequency drifting islanding detection methods[J]. IEEE Transactions on Energy Conversion,2006,21(1):171-189.
[16]  WEI Quan,WANG Yifei,ZHU Jing,et al. Combined active islanding detection method for grid-connected photovoltaic system[J]. High Voltage Apparatus,2014,50(10):37-42.
[17]  YE Z H,KOLWALKAR A,ZHANG Y,et al. Evaluation of anti-islanding schemes based on nondetection zone concept[J]. IEEE Transactions on Power Electronics,2004,19(5):1171-1176.
[18]  刘方锐,康 勇,张 宇,等. 带正反馈的主动移频孤岛检测法的参数优化[J]. 电工电能新技术,2008,27(3):22-25. LIU Fangrui,KANG Yong,ZHANG Yu,et al. Parameter optimization for active frequency drift with positive feedback islanding detection strategy[J]. Advanced Technology of Electrical Engineering and Energy,2008,27(3):22-25.
[19]  刘芙蓉,康 勇,段善旭,等. 主动移频式孤岛检测方法的参数优化[J]. 中国电机工程学报,2008,28(1):95-99. LIU Furong,KANG Yong,DUAN Shanxu,et al. Parameter optimization of active frequency drift islanding detection method[J]. Proceedings of the Chinese Society for Electrical Engineering,2008,28(1):95-99.