[1] | DL/T 755―2001 电力系统安全稳定导则[S]. 2001.
|
[2] | 王梅义,吴竞昌,蒙定中. 大电网系统技术[M]. 北京:水利电力出版社,2001. WANG Meiyi,WU Jingchang,MENG Dingzhong. Technology of great power system[M]. Beijing: China Electric Power Press,2001.
|
[3] | 孔 涛,王洪涛,刘玉田,等. 500 kV-220 kV电磁环网开环研究[J]. 电力自动化设备,2003,23(12):13-16. KONG Tao,WANG Hongtao,LIU Yutian,et al. On opening 500 kV-220 kV electromagnetic loop circuit[J]. Electric Power Automation Equipment,2003,23(12):13-16.
|
[4] | 杨 冬,刘玉田,牛新生. 电网结构对短路电流水平及受电能力的影响分析[J]. 电力系统保护与控制,2009,37(22):62-67. YANG Dong,LIU Yutian,NIU Xinsheng. Analysis on influence of power grid structure upon short circuit level and power receiving capability[J]. Power System Protection and Control,2009,37(22):62-67.
|
[5] | 白宏坤,李干生. 关于电磁环网弱开环方式的探讨[J]. 电力系统保护与控制,2010,38(2):60-63. BAI Hongkun,LI Gansheng. Discussion on weak open-loop mode of electromagnetic loop[J]. Power System Protection and Control,2010,38(2):60-63.
|
[6] | 白宏坤,李干生. 郑州220 kV电磁环网解环规划研究[J].电力系统保护与控制,2011,39(7):127-132. BAI Hongkun,LI Gansheng. Study on open-loop planning of 220 kV electromagnetic ring in Zhengzhou[J]. Power System Protection and Control,2011,39(7):127-132.
|
[7] | 刘 青. 宝能220 kV GIS变电站雷电侵入波过电压的研究[J]. 高压电器,2008,44(2):142-144. LIU Qing. Research on lightning intruding waves in 220 kV baoneng gas insulated substation[J]. High Voltage Apparatus,2008,44(2):142-144.
|
[8] | 刘兆林. 雷击引起的高压断路器故障分析[J]. 高压电器,2009,45(3):66-69. LIU Zhaolin. Analysis of the lightning strike faults on the HV circuit breaker[J]. High Voltage Apparatus,2009,45(3):66-69.
|
[9] | 高 媛,王宏斌,雷 娟,等. 750 kV敞开式变电站雷电侵入波的防护[J]. 高压电器,2008,44(5):445-448. GAO Yuan,WANG Hongbin,LEI Juan,et al. Lightning protection of 750 kV AIS substation against intruding wave[J]. High Voltage Apparatus,2008,44(5):445-448.
|
[10] | 童世奇,胡晓波. 输电线路雷击故障的复现分析方法研究[J]. 陕西电力,2014,42(7):45-48. TONG Shiqi,HU Xiaobo. Recurrence analysis method study of transmission line lightning failures[J]. Shaanxi Electric Power,2014,42(7):45-48.
|
[11] | 吕建安. 10 kV输电线路雷击原因及防雷措施的探讨[J].陕西电力,2013,41(7):100-101. LYU Jian’an. Lightening reason analysis of 10 kV transmission line & its prevention measures[J]. Shaanxi Electric Power,2013,41(7):100-101.
|
[12] | 韩永霞,卢毓欣,陈辉祥,等. ±800 kV换流站的雷电侵入波过电压仿真分析[J].高电压技术,2010,36(1):218-223. HAN Yongxia,LU Yuxin,CHEN Huixiang,et al. Simulation analysis on lightning intruding overvoltage of the ±800 kV converter station[J]. High Voltage Engineering,2010,36(1):218-223.
|
[13] | 甘凌霞,李 雷,李景禄. 500 kV GIS变电站雷电过电压保护研究[J]. 高压电器,2009,45(6):110-114. GAN Lingxia,LI Lei,LI Jinglu. Lightning over-voltage protection for 500 kV GIS substation[J]. High Voltage Apparatus,2009,45(6):110-114.
|
[14] | 孙 强. 一起800 kV断路器绝缘故障的原因分析[J]. 高压电器,2009,45(2):132-134. SUN Qiang. Analysis of insulation accident of 800 kV circuit-breaker in guanting transformer substation[J]. High Voltage Apparatus,2009,45(2):132-134.
|
[15] | 郝建成,张军阳,田 勇. 线路遭受连续雷击造成断路器事故分析[J]. 高压电器,2010,46(10):105-108. HAO Jiancheng,ZHANG Junyang,TIAN Yong. Faults analysis of circuit-breaker caused by continuous lighting strike on lines[J]. High Voltage Apparatus,2010,46(10):105-108.
|
[16] | DL/T 620―1997 交流电气装置的过电压保护和绝缘配合[S]. 1997. DL/T 620-1997 Overvoltage protection and insulation coordination for AC electrical installations[S]. 1997.
|
[17] | 李汝彪,张东波. 高压断路器雷击损坏故障分析与措施[J]. 高压电器,2008,44(5):466-468. LI Rubiao,ZHANG Dongbo. Analysis of circuit breaker failures due to lightning strokes[J]. High Voltage Apparatus,2008,44(5):466-468.
|
[18] | 朱胜龙,叶剑涛,李 伟. 断路器遭雷击损坏的事故分析及防雷措施改进[J]. 电气应用,2008,27(1):47-50. ZHU Shenglong,YE Jiantao,LI Wei.Analysis of circuit breaker faults caused by multi-lightning strokes and improved prevention measures[J]. Electrotechnical Application,2008,27(1):47-50.
|
[19] | 施中郎. 带电开口运行断路器雷击事故分析及防范措施[J]. 电力设备,2005,6(6):63-65. SHI Zhonglang. Fault analysis and prevention measure of lightning for electrified open operation circuit breaker[J]. Electrical Equipment,2005,6(6):63-65.
|
[20] | 施中郎. 带电开口运行开关防雷击过电压的探讨[J]. 高压电器,2005,41(6):468-470. SHI Zhonglang. Research on electrified-opened-swith protected from lightning overvoltage[J]. High Voltage Apparatus,2005,41(6):468-470.
|
[21] | 陈锦清,李端姣,江健武. 热备用状态下的断路器雷击事故分析[J]. 高电压技术,2001,27(5):69-71. CHEN Jinqing,LI Duanjiao,JIANG Jianwu. The analysis report of the lightning-strike accident occurred in the stand-by circuit-breaker[J]. High Voltage Engineering,2001,27(5):69-71.
|
[22] | 叶会生,何俊佳,李 化,等. 雷击高压直流线路杆塔时的过电压和闪络仿真研究[J]. 电网技术,2005,29(21):31-35. YE Huisheng,HE Junjia,LI Hua,et al. Simulation of overvoltage and flashover caused by lightning stroke at towers of HVDC transmission line[J]. Power System Technology,2005,29(21):31-35.
|
[23] | 赵紫辉,吴广宁,曹晓斌. 计及冲击电晕的输电线路雷电过电压影响因素研究[J]. 电瓷避雷器,2013(2):109-118. ZHAO Zihui,WU Guangning,CAO Xiaobin. Influence factors research on lightning overvoltage of transmission lines considering the effect of impulse corona[J]. Insulators and Surge Arresters,2013(2):109-118.
|
[24] | 杨 杰,郑宇清,吕晓燕. 高压输电线路雷击故障分析[J]. 电瓷避雷器,2013(6):61-64. YANG Jie,ZHENG Yuqing,LYU Xiaoyan. Analysis on lighting strike faults of electric transmission line for EHV[J]. Insulators and Surge Arresters,2013(6):61-64.
|
[25] | 刘 青,张玉峰,程 勇. 220 kV GIS变电站雷电过电压防护措施的研究[J]. 高压电器,2008,44(4):329-331. LIU Qing,ZHANG Yufeng,CHENG Yong. Research on protection against lightning over-voltage on transformer in a 220 kV GIS substation[J]. High Voltage Apparatus,2008,44(4):329-331.
|