[1] | 罗竹杰,张杏梅. 电力用油与六氟化硫[M]. 北京:中国电力出版社,2007. LUO Zhujie,ZHANG Xingmei. Power oil and six sulfur hexafluoride[M]. Beijing: China Electric Power Press,2007.
|
[2] | 梁方建,王 钰,王志龙,等. 六氟化硫气体在电力设备中的应用现状及问题[J]. 绝缘材料,2010,43(3):43-46. LIANG Fangjian,WANG Yu,WANG Zhilong,et al. The application situation of SF6 in electrical equipment and some problem[J]. Insulating Materials,2010,43(3):43-46.
|
[3] | 杜晓平,李 涛,李景华,等. 气体绝缘组合电器(GIS)事故原因分析及建议[J]. 绝缘材料,2009,42(3):67-68. DU Xiaoping,LI Tao,LI Jinghua,et al. The gas insulated switchgear(GIS)accident analysis and countermeasures[J]. Insulating Materials,2009,42(3): 67-68.
|
[4] | 王学军. 超临流体色谱法分析大豆磷脂[J]. 色谱,2001,19(4):344-346. WANG Xuejun. Analysis of soybean lecithin by supercritical fluid chromatography[J]. Chromatography,2001,19(4):344-346.
|
[5] | 王维宗,岳辅鹏,夏书纲. 气相色谱―质谱联用技术在六氟化硫气体痕量杂质分析中的应用[J]. 质谱学报,1982(1):24-27. WANG Weizong,YUE Fupeng,XIA Shugang. Application of gas chromatography-mass spectrometry in the analysis of six SF6 trace impurities[J]. Journal of Mass Spectrometry,1982(1):24-27.
|
[6] | 张仲旗,连鸿松. 通过检测SO2发现SF6电气设备故障[J]. 中国电力,2001,34(1):77-80. ZHANG Zhongqi,LIAN Hongsong. Using SO2 detection for failure checking of SF6 electricity equipment[J]. Electric Power,2001,34(1):77-80.
|
[7] | 张丽娜,陈永义,梁桂州. 关于GIS 和SF6 断路器的现场检测方法[J]. 高压电器,2001,37(3):47-48. ZHANG Lina,CHEN Yongyi,LIANG Guizhou. Method for the detection of site on GIS and SF6 circuit breaker[J]. High Voltage Apparatus,2001,37(3):47-48.
|
[8] | IEC 60480―2004 Guide lines for the checking and treatment of sulfur hexafluoride(SF6) taken from electrical equipment and specification for its re-use[S]. 2004.
|
[9] | 张晓星,姚 尧,唐 炬,等. SF6放电分解气体组分分析的现状和发展[J]. 高电压技术,2008,34(4):664-669. ZHANG Xiaoxing,YAO Yao,TANG Ju,et al. The present situation and development of SF6 discharge decomposition of gas components analysis[J]. High Voltage Engineering, 2008,34(4):664-669.
|
[10] | 翁诗甫. 傅里叶变换红外光谱仪[M]. 北京:化学工业出版社,2005. WENG Shifu. Fourier transform infrared spectrometer[M]. Beijing: Chemical Industry Press,2005.
|
[11] | 蔡 巍,黄韬颖,李 帆. 动态离子分析在SF6电气绝缘设备诊断中的应用[J]. 华北电力技术,2006(1):31-33. CAI Wei,HUANG Taoying,LI Fan. Application of ion mobility spectrometry technique in diagnosis of gas condition in SF6 electric insulating equipment[J]. North China Electric Power,2006(1):31-33.
|
[12] | 范康年. 谱学导论[M]. 北京:高等教育出版社,2001. FAN Kangnian. Spectroscopy introduction[M]. Beijing: Higher Education Press,2001.
|
[13] | OKABE S,KANEKO S,MINAGAWA T,et al. Detecting characteristics of SF6 decomposed gas sensor for insulation diagnosis on gas insulated switchgears[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2008,15(1):251-258.
|
[14] | CHU F Y. SF6 decomposition in gas-insulated equipment[J]. IEEE Transactions on Electrical Insulation,1986,EI-21(5): 693-725.
|
[15] | QIU Y,KUFFEL E. Compares on of SF6 /N2 and SF6/CO2 gas mixtures as alternatives to SF6 gas[J]. IEEE Transactions on Dielectrics and Electrical Insulation,1999,6(6):892-895.
|
[16] | 季严松,王承玉,杨 韧,等. SF6气体分解产物检测技术及其在GIS设备故障诊断中的应用[J]. 高压电器,2011, 47(2):100-103. JI Yansong,WANG Chengyu,YANG Ren,et al. Measuring technique of SF6 decomposition products and its application to fault diagnosis of GIS[J]. High Voltage Apparatus,2011,47(2):100-103.
|
[17] | 晏年平,童军心,周求宽,等. SF6气体绝缘电流互感器放电击穿过程分析[J]. 变压器,2013,50(11):56-59. YAN Nianping,TONG Junxin,ZHOU Qiukuan,et al. Analysis of discharge breakdown process of SF6 gas-insulated current transformer[J]. Transformer,2013,50(11): 56-59.
|
[18] | 吴 瀛,陈 禾,张新波. 换流变压器阀侧套管SF6 气体密度表选型研究[J]. 变压器,2013,50(3):63-65. WU Ying,CHEN He,ZHANG Xinbo. Research on type selection of SF6 gas density meter on valve side bushing in converter transformer[J]. Transformer,2013,50(3):63-65.
|
[19] | 陈晓清,任 明,彭华东,等. GIS设备中SF6气体分解影响因素分析[J]. 电网与清洁能源,2010,26(7):34-38. CHEN Xiaoqing,REN Ming,PENG Huadong,et al. An analysis on affecting factors of SF6 gas decomposition in GIS equipment[J]. Power System and Clean Energy,2012,28(12):38-41.
|
[20] | 林海渊,林碧莺,张秀霞. 交流电晕放电下SF6气体分解物的光谱检测[J]. 电网与清洁能源,2014,30(2):52-59. LIN Haiyuan,LIN Biying,ZHANG Xiuxia. Spectra measurement of SF6 gas decomposition under AC corona discharges[J]. Power System and Clean Energy,2014,30(2):52-59.
|