带有可更换构件的结构体系研究进展

DOI: 10.13197/j.eeev.2014.01.27.luxl.004, PP. 27-36

Keywords: 可更换构件,耗能减震,结构体系,可修复

Full-Text   Cite this paper   Add to My Lib

Abstract:

带有可更换构件的结构体系是指,在结构中适当部位设置可更换构件,通过集中塑性变形耗散地震能量,保护结构其余部分不受破坏,地震后不影响结构的使用,更换构件后结构全部恢复正常功能。本文介绍了带有可更换构件结构体系的发展现状,总结了带有可更换构件的桥梁结构、框架结构、框架-支撑结构、剪力墙结构的研究进展,并探讨了今后的研究方向及重点领域。

References

[1]  吕西林, 陈 云, 毛苑君. 结构抗震设计的新概念――可恢复功能结构[J]. 同济大学学报:自然科学版, 2011, 39(7): 941-948. LU Xilin, CHEN Yun, MAO Yuanjun. New concept of structural seismic design: earthquake resilient structures[J]. Journal of Tongji University:Natural Science, 2011, 39(7): 941-948.(in Chinese)
[2]  Tang M C, Manzanarez R. San Francisco-Oakland bay bridge design concepts and alternatives[C]// Chang P C. Structures 2001: a Structural Engineering Odyssey, ASCE, 2001: 1-7.
[3]  McDaniel C C, Seible F. Influence of inelastic tower links on cable-supported bridge response[J]. Journal of Bridge Engineering, 2005, 10(3): 272-280.
[4]  McDaniel C C, Uang C M, Seible F. Cyclic testing of built-up steel shear links for the new bay bridge[J]. Journal of Structural Engineering-Asce, 2003, 129(6): 801-809.
[5]  Marriott D, Pampanin S, Palermo A. Quasi-static and pseudo-dynamic testing of unbonded post-tensioned rocking bridge piers with external replaceable dissipaters[J]. Earthquake Engineering & Structural Dynamics, 2009, 38(3): 331-354.
[6]  Marriott D, Pampanin S, Palermo A. Biaxial testing of unbonded post-tensioned rocking bridge piers with external replacable dissipaters[J]. Earthquake Engineering & Structural Dynamics, 2011, 40(15): 1723-1741.
[7]  El-Bahey S, Bruneau M. Bridge piers with structural fuses and bi-steel columns. i: experimental testing[J]. Journal of Bridge Engineering, 2012, 17(1): 25-35.
[8]  El-Bahey S, Bruneau M. Bridge piers with structural fuses and bi-steel columns. ii: analytical investigation[J]. Journal of Bridge Engineering, 2012, 17 (1): 36-46.
[9]  El-Bahey S, Bruneau M. Buckling restrained braces as structural fuses for the seismic retrofit of reinforced concrete bridge bents[J]. Engineering Structures, 2011, 33(3): 1052-1061.
[10]  Chou C C, Wu C C. Performance evaluation of steel reduced flange plate moment connections[J]. Earthquake Engineering & Structural Dynamics, 2007, 36(14): 2083-2097.
[11]  Farrokhi H, Danesh F, Eshghi S. A modified moment resisting connection for ductile steel frames (Numerical and experimental investigation)[J]. Journal of Constructional Steel Research, 2009, 65(10-11): 2040-2049.
[12]  Oh S H, Kim Y J, Ryu H S. Seismic performance of steel structures with slit dampers[J]. Engineering Structures, 2009, 31(9):1997-2008.
[13]  Castiglioni C A, Kanyilmaz A, Calado L. Experimental analysis of seismic resistant composite steel frames with dissipative devices[J].Journal of Constructional Steel Research, 2012, 76: 1-12.
[14]  Castiglioni C A, Kanyilmaz A, Drei A, et al. Seismic resistant composite steel frames with dissipative devices[C]// STESSA 2012: Proceedings of the 7th International Conference on Behaviour of Steel Structures in Seismic Areas, Crc Press-Taylor & Francis Group,2012: 785-789.
[15]  Calado L, Proen?a J M, Espinha M, et al. Hysteretic behaviour of dissipative bolted fuses for earthquake resistant steel frames[J]. Journal of Constructional Steel Research, 2013, 85(0): 151-162.
[16]  Shen Y L, Christopoulos C, Mansour N, et al. Seismic design and performance of steel moment-resisting frames with nonlinear replaceable links[J]. Journal of Structural Engineering-Asce, 2011, 137(10): 1107-1117.
[17]  Chi H, Liu J. Seismic behavior of post-tensioned column base for steel self-centering moment resisting frame[J]. Journal of Constructional Steel Research, 2012, 78: 117-130.
[18]  Vargas R, Bruneau M. Analytical response and design of buildings with metallic structural fuses. I[J]. Journal of Structural Engineering-Asce, 2009, 135(4): 386-393.
[19]  Vargas R, Bruneau M. Experimental response of buildings designed with metallic structural fuses. II[J]. Journal of Structural Engineering-Asce, 2009, 135(4): 394-403.
[20]  Mansour N, Christopoulos C, Tremblay R. Experimental validation of replaceable shear links for eccentrically braced steel frames[J].Journal of Structural Engineering-Asce, 2011, 137(10): 1141-1152.
[21]  Iwai R, Dusicka P. Development of linked column frame system for seismic lateral loads[C]// Structures Congress 2007: Structural Engineering Research Frontiers, ASCE, 2007: 1-13.
[22]  Dusicka P, Lewis G R. Investigation of replaceable sacrificial steel links[C]// 9th US National and 10th Canadian Conference on Earthquake Engineering 2010, including Papers from the 4th International Tsunami Symposium, Earthquake Engineering Research Institute, 2010: 3556-3565.
[23]  Malakoutian M, Berman J W, Dusicka P. Seismic response evaluation of the linked column frame system[J]. Earthquake Engineering & Structural Dynamics, 2013, 42(6): 795-814.
[24]  Lopes A P, Dusicka P, Berman J W. Design of the Linked Column Frame structural system[C]// Stessa 2012: Proceedings of the 7th International Conference on Behaviour of Steel Structures in Seismic Areas, Crc Press-Taylor & Francis Group, 2012: 311-317.
[25]  Lopes A, Dusicka P, Berman J. Linked column framing system analyses toward experimental validation[C]// Structures Congress2012, ASCE, 2012: 1598-1609.
[26]  Lin C H, Tsai K C, Qu B, et al. Sub-structural pseudo-dynamic performance of two full-scale two-story steel plate shear walls[J]. Journal of Constructional Steel Research, 2010, 66(12): 1467-1482.
[27]  Qu B, Bruneau M, Lin C H, et al. Testing of full-scale two-story steel plate shear wall with reduced beam section connections and composite floors[J]. Journal of Structural Engineering-Asce, 2008, 134(3): 364-373.
[28]  Cortés G, Liu J. Experimental evaluation of steel slit panel-frames for seismic resistance[J]. Journal of Constructional Steel Research, 2011, 67(2): 181-191.
[29]  Hebdon M, Lloyd J, Liu J. Practical design considerations for steel slit panel frames[C]// Structures Congress 2012: Proceedings of the 2012 Structures Congress, ASCE, 2012: 1577-1585.
[30]  Ozaki F, Kawai Y, Kanno R, et al. Damage-control systems using replaceable energy-dissipating steel fuses for cold-formed steel structures: seismic behavior by shake table tests[J]. Journal of Structural Engineering-Asce, 2013, 139(5): 787-795.
[31]  吕西林, 毛苑君. 带有可更换墙脚构件剪力墙的设计方法[J]. 结构工程师, 2012, 28(3): 12-17. LU Xilin, MAO Yuanjun. Design method for RC shear walls with replaceable foot parts[J]. Structural Engineers, 2012, 28(3): 12-17.(in Chinese)
[32]  Chen Y, Lu X L. New replaceable coupling beams for shear wall structures[C]// 15WCEE, Lisbon, Portugal, Paper-ID: 2583, September 24-28, 2012.
[33]  吕西林, 陈 云, 蒋欢军. 新型可更换连梁研究进展[J]. 地震工程与工程振动, 2013,33(1): 8-15. LU Xilin, CHEN Yun, JIANG Huanjun. Research progress in new replaceable coupling beams[J]. EARTHQUKE ENGINEERING AND ENGINEERING DYNAMICS, 2013, 33(1): 8-15. (in Chinese)
[34]  Wang T, Guo X, He X K, et al. Experimental study on replaceable hybrid coupling beams[J]. Applied Mechanics and Materials, 2012, 166-169: 1779-1784.