添加钢筋提高隔震结构高宽比限值的研究

, PP. 120-125

Keywords: 钢筋,隔震,高宽比,构造,周期

Full-Text   Cite this paper   Add to My Lib

Abstract:

提出了在边支座上添加竖向钢筋以提高隔震结构高宽比限值的构造措施;从方案的构造、添加钢筋的工作状态以及对隔震效果的影响等方面论证了该措施的可行性;基于《建筑抗震设计规范》(GB50011-2001),推导了添加竖向钢筋后隔震结构高宽比限值的公式;可行性论证和实际算例的计算结果表明,本方案技术可行、效果显著。

References

[1]  GB50011-2001,建筑结构抗震设计规范[S].
[2]  Takenaka Corporation.Construction completed of "Park City Suginami,"theWorld’s Tallest Base-Isolated superhigh-rise condominium,a reverse concept for improved seismic response[Z].http://www.Takenaka.co.jp/takenak a_e/n ew s_e/p r0011/m 0011_01.htm,2000.
[3]  Takenaka Corporation.Hybrid base isolation system used in superhigh-rise office building for the first time in theworld,a reverse concept for improved seismic response[Z].http://www.Takenaka.co.jp/takenaka_e/new s_e/p r0106/m 0106_06.htm,2001.
[4]  Takenaka Corporation.Creation of stepping vibration control, a reverse concept for improved seismic response[Z].http://www.Takenak a.co. jp/takenaka_e/newse/pr0102/m 0102_06.htm,2001.
[5]  陈永祥.叠层钢板橡胶垫基础隔震结构的应用研究[D].辽宁:沈阳建筑工程学院,2002.34~41.