矿床地质  2008 

MC-ICP-MS高精度Cu、Zn同位素测试技术

Keywords: 地球化学,Cu、Zn同位素测定,MC-ICP-MS,质量歧视,基质效应

Full-Text   Cite this paper   Add to My Lib

Abstract:

过渡族元素同位素是国际上同位素地球化学研究的热点。测试技术的限制是制约过渡元素同位素研究发展的关键。笔者利用Neptune型多接收等离子质谱(MC_ICP_MS),采用Cu、Zn互为内标的方法对仪器的质量歧视进行了校正,对基质效应和测试方法的重现性进行了检验,建立了高精度的Cu、Zn同位素测试技术。在5个月内对实验室标准IMRCu和IMRZn进行了测量,结果分别为δ65CuNIST976=(0.34±0.08)‰(2SD,n=32),δ66ZnJMCZn=(-9.64±0.05)‰(2SD,n=26),δ67ZnJMCZn=(-14.37±0.16)‰(2SD,n=26),δ68ZnJMCZn=(-19.01±0.08)‰(2SD,n=26),分析精度达到国际同类实验室先进水平。对Cu、Zn同位素参考物质进行了对比测量,分析结果与报道值在误差范围内完全一致。

References

[1]  更多...
[2]  Zhu X K, Makishima A, Guo Y, Belshaw N S and O\\' Nions R K. 2002. High precision measurement of titanium isotope ratios by plasma source mass spectrometry[J]. Intenational Journal of Mass Spectrometry, 220: 321-29.
[3]  Anbar A D and Rouxel O. 2007. Metal stable isotopes in paleo- ceanography[J]. Annual Review of Earth and Planetary Sciences, 35: 717-46.
[4]  Anord G L, Weyer S and Anhar A D. 2004. Fe isotope variations in natural materials measured using high mass resolution multiple collector ICPMS[J]. Analytical Chemistry, 76: 322-327.
[5]  Belshaw N S, Zhu X K, Guo Y and O\\' Nions R K. 2000. High precision measurement of iron isotopes by plasma source mass spectrometry [J]. International Journal of Mass Spectrometry, 197: 191-195.
[6]  Cloquet C, Carignan J and Libourel G. 2006. Insights from the BRAVO study on nesting global models to specify boundary conditions in regional air quality modeling simulations[J]. Atmospheric Environment, 40: 574-587.
[7]  Cloquet C, Carignan J, Lehmann M F and Vanhaeeke F. 2008. Variation in the isotopic composition of zinc in the natural environment and the use of zinc isotopes in biogeoseiences: A review[J]. Analytical and Bioanalytical Chemistry, 390: 451-463.
[8]  Dideriksen K, Balke J and Stipp S. 2006. Iron isotopes in natural carbonate mineral determined by MC-ICP-MS with a 58Fe-54Fe double spike[J]. Geochimica et Cosmochimica Acta, 70: 118-132.
[9]  Eiler J M, Graham C and Valley J W. 1997. SIMS analysis of oxygen isotopes: Matrix effects in complex minerals and glasses[J]. Chemical Geology, 138: 221-224.
[10]  Jiang S Y, Wood_head J, Yu J M, Pan J Y, Liao Q L and Wu N P. 2002. A reconnaissance of Cu isotopic compositions of hydrothermal vein-type copper deposit, Jinman, Yunnan, China[J]. Chinese Science Bulletin, 47: 247-250.
[11]  John S G, Park J G, Zhang Z and Boyle E A. 2007. The isotopic composition of some common forms of anthropogenic zinc[J]. Chemical Geology, 245(1-2): 61-69.
[12]  Li J. 2008. Transition metal isotope fractionation at low temperatures, and its applications in paleoceanography(PhD candidate paper) [D]. Supervisor: Zhu X K. Beijing: Chinese Academy of Geological Sciences. 68p.
[13]  Marechal C N, Telouk P and Albarede F. 1999. Precise analysis of copper and zinc isotopic compositions by plasma source mass spectrometry[J]. Chemical Geology, 56: 251-273.
[14]  Rormy Sehoenberg and Friedhelm yon Blanckenburg. 2005. An assessmerit of the accuracy of stable Fe isotope ratio measurements on samples with organic and inorganic matrices by high-resolution multicollector ICP-MS[J]. International Journal of Mass Spectrometry 242: 257-272.
[15]  Rosman K J R and Taylor P D P. 1998. Isotopic compositions of the elements[J]. Pure Appl. Chem., 70: 217-235.
[16]  Rosman K J R. 1972. A survey of the isotopic and elemental abundances of zinc[J]. Geochimica et Cosmochimica Acta, 36 : 801-819.
[17]  Schoenberg R end Blenekenburg F. 2005. An assesament of the accuracy of stable Fe isotope ratio measurements on samples with organic end inorganie rnatriees by high-resolution multicolleetor ICP-MS [J]. International Journal of Mass Spectrometry, 242: 257-272.
[18]  Shield W R, Goldich S S and Garner E L. 1965. Nature variations in the abundance ratio and the atomic weight of copper[J]. Journal of Geophysical Research, 70: 479-491.
[19]  Tang S H, Zhu X K, Cai J J, Li S Z, He X X and WangJ H. 2006. Chromatographic separation of Cu, Fe and Zn using AG MP-1 Anion Exchange resin for isotope determination by MC-ICP-MS [J]. Rock and Mineral Analysis, 25(1): 5-8.
[20]  Tanimizu M, Asada Y and Hirata T. 2002. Absolute isotopic composition and atomic weight of commercial zinc using inductively coupled plasma mass spectrometry[J]. Analytical Chemistry, 74: 5814- 5819.
[21]  Woodhead J. 2002. A simple method for obtaining highly accurate Pb isotope data by MC-ICP-MS[J]. Journal of Analytical Atomic Spectrometry, 17:1381-1385.
[22]  Zhu X K, O\\' Nions R K, Guo Y, Belshaw N S and Rickard D. 2000. Determination of natural Cu-isotope variation by plasma-source mass spectrometry: implications for use as geochemical tracers [J]. Chemical Geology, 163: 139-149.