局部无压浆PC构件抗弯性能试验及计算方法

, PP. 64-74

Keywords: 桥梁工程,PC构件,静载试验,抗弯性能,局部无压浆

Full-Text   Cite this paper   Add to My Lib

Abstract:

?为了解决既有预应力混凝土(PC)桥梁压浆不密实和漏压浆问题,开展了不同压浆状态的PC梁静载试验,揭示了局部无压浆长度、位置等对构件抗弯性能的影响,进而考虑无压浆段预应力筋与混凝土间的变形不协调以及材料非线性,给出了局部无压浆构件极限承载力和受弯全过程荷载-挠度变形的计算方法。研究结果表明:局部无压浆引起的预应力筋与混凝土间的粘结性能退化对构件裂缝分布和扩展影响较大,导致裂缝数量减少、平均间距增大、极限状态时最大裂缝宽度变大;局部无压浆仅影响构件开裂后的荷载-挠度行为,且受其所处位置和长度共同制约,纯弯段无压浆对荷载-挠度行为影响较小,而弯剪段无压浆造成的影响较大,弯剪段无压浆长度越长构件刚度和承载力退化越明显;所提出的计算方法计算结果与试验结果较为吻合,精度较高。

References

[1]  TREJO D,PILLAI R G,HUESTE M B D,et al.Parameters Influencing Corrosion and Tension Capacity of Post-tensioning Strands[J].ACI Materials Journal,2009,106(2):144-153.
[2]  刘其伟,张鹏飞,吴建平.实桥预应力孔道压浆调查和钢丝性能分析[J].桥梁建设,2006(5):72-75.LIU Qi-wei,ZHANG Peng-fei,WU Jian-ping.Investigation of Duct Grouting and Analysis of Steel Wire Behavior of an Actual Post-tensioned Concrete Bridge[J].Bridge Construction,2006(5):72-75.
[3]  朱坤宁,叶见曙.后张法箱梁孔道压浆密实程度调查[J].现代交通技术,2007,4(1):39-42.ZHU Kun-ning,YE Jian-shu.Investigation of Duct Grouting Compactness of Post-prestressed Box Girder[J].Modern Transportation Technology,2007,4(1):39-42.
[4]  吴文清,陈小刚,李 波,等.预应力混凝土连续箱梁施工质量评价指标调查[J].建筑科学与工程学报,2009,26(3):42-48.WU Wen-qing,CHEN Xiao-gang,LI Bo,et al.Investigation of Construction Quality Evaluating Indices in PC Continuous Box-girder [J].Journal of Architecture and Civil Engineering,2009,26(3):42-48.
[5]  EL ZGHAYAR E,MACKIE K R,HABER Z B,et al.Secondary Anchorage in Post-tensioned Bridge Systems[J].ACI Structural Journal,2013,110(4):629-638.
[6]  WOOD S L,MCKINSTRY C A,LEE J K.Residual Tensile Capacity of Grouted Post-tensioned Tendons[J].ACI Structural Journal,2013,110(6):1099-1108.
[7]  LI F M,YUAN Y S.Effects of Corrosion on Bond Behavior Between Steel Strand and Concrete[J].Construction and Building Materials,2013,38:413-422.
[8]  WOUTERS J P,KESNER K,POSTON R W.Tendon Corrosion in Precast Segmental Bridges[J].Transportation Research Record,1999,1654:128-132.
[9]  OHTSU M,ALVER N.Development of Non-contact SIBIE Procedure for Identifying Ungrouted Tendon Duct[J].NDT & E International,2009,42(2):120-127.
[10]  FRICKER S,VOGEL T.Site Installation and Testing of a Continuous Acoustic Monitoring[J].Construction and Building Materials,2007,21(3):501-510.
[11]  YAMADA M,OHTSU M.Case Studies on Ungrouted Tendon-duct in Prestressed Concrete Models by SIBIE[J].Construction and Building Materials,2010,24(12):2376-2380.
[12]  SCHOEFS F,ABRAHAM O,POPOVICS J S.Quantitative Evaluation of Contactless Impact Echo for Non-destructive Assessment of Void Detection Within Tendon Ducts[J].Construction and Building Materials,2012,37:885-892.
[13]  周先雁,王智丰,晏班夫.预应力管道压浆质量无损检测方法[J].中国公路学报,2011,24(6):64-71.ZHOU Xian-yan,WANG Zhi-feng,YAN Ban-fu.Nondestructive Testing Method of Grouting Quality for Prestressed Pipe[J].China Journal of Highway and Transport,2011,24(6):64-71.
[14]  朱尔玉,王冰伟,周勇政,等.预应力孔道灌浆密实性及防治泌水方法的试验研究[J].水利学报,2012,43(5):609-614.ZHU Er-yu,WANG Bing-wei,ZHOU Yong-zheng,et al.Experimental Study on Grouting Compactness of Prestressed Duct and Technology to Deal with the Grout Bleeding[J].Journal of Hydralic Engineering,2012,43(5):609-614.
[15]  PILLAI R G,GARDONI P,TREJO D,et al.Probabilistic Models for the Tensile Strength of Corroding Strands in Posttensioned Segmental Concrete Bridges[J].Journal of Materials in Civil Engineering,2010,22(10):967-977.
[16]  GARDONI P,PILLAI R G,HUESTE M B D,et al.Probabilistic Capacity Models for Corroding Posttensioning Strands Calibrated Using Laboratory Results[J].Journal of Engineering Mechanics,2009,135(9):906-916.
[17]  PILLAI R G,HUESTE M D,GARDONI P,et al.Time-variant Service Reliability of Post-tensioned,Segmental,Concrete Bridges Exposed to Corrosive Environments[J].Engineering Structures,2010,32(9):2596-2605.
[18]  MINH H,MUTSUYOSHI H,NIITANI K.Influence of Grouting Condition on Crack and Load-carrying Capacity of Post-tensioned Concrete Beam Due to Chloride-induced Corrosion[J].Construction and Building Materials,2007,21(7):1568-1575.
[19]  MINH H,MUTSUYOSHI H,TANIGUCHI H,et al.Chloride-induced Corrosion in Insufficiently Grouted Posttensioned Concrete Beams[J].Journal of Materials in Civil Engineering,2008,20(1):85-91.
[20]  COLLINS M,MITCHELL D.Prestressed Concrete Structure[M].London:Prentice Hall,1991.
[21]  CEB-FIP Model Code 1990,Design Code[S].