Meng H, Chen S, Guan Y L, et al.Modeling of transfer characteristics for the broadband power line communication channel[J].IEEE Transactions on Power Delivery, 2004, 19(3):1061-1063.
[2]
Lazaropoulos A G, Cottis P G.Transmission characteristics of overhead medium-voltage power-line communication channels[J].IEEE Transactions on Power Delivery, 2009, 24(3):1164-1173.
[3]
Cataliotti A, Di Cara D, Fiorelli R, et al.Power-line communication in medium-voltage system simulation model and on field experimental tests[J].IEEE Transactions on Power Delivery, 2012, 27(1):62-69.
[4]
李荣伟, 吴乐南.10kV中压配电线载波信道的建模[J].电路与系统学报, 2006, 11(6):19-24.Li Rongwei, Wu Lenan.Modeling of carrier channel over 10kV distribution lines[J].Journal of Circuit and Systems, 2006, 11(6):19-24(in Chinese).
[5]
蔡伟, 乐健, 刘开培, 等.基于信息节点的智能配电网中压电力线载波通信信道建模方法[J].中国电机工程学报, 2012, 32(28):150-156.Cai Wei, Le Jian, Liu Kaipei, et al.A channel modeling technology for the medium-voltage power-line carrier in smart power distribution grid[J].Proceedings of the CSEE, 2012, 32(28):150-156(in Chinese).
[6]
Benato R, Caldon R.Distribution line carrier:analysis procedure and applications to DG[J].IEEE Transactions on Power Delivery, 2007, 22(1):575-583.
[7]
Lee Dae-Eun, In Dong-Seok, Lee Jae-Jo, et al.A field trial of medium voltage power line communication system for AMR and DAS[C]//Transmission & Distribution Conference & Exposition:Asia and Pacific.Seoul, Korea:IEEE, 2009:1-4.
[8]
杨晓宪, 郑涛, 张保会, 等.10 kV中压电力线信道传输特性测量与研究(一):信道传输的一般特性[J].电力自动化设备, 2006, 26(11):1-7.Yang Xiaoxian, Zheng Tao, Zhang Baohui, et al.Measurement and research of channel transmission properties on 10 kV medium voltage power lines, part 1: general properties[J].Electric Power Automation Equipment, 2006, 26(11):1-7(in Chinese).
[9]
杨晓宪, 郑涛, 张保会, 等.10 kV中压电力线信道传输特性测量与研究(二):信道传输路径损失[J].电力自动化设备, 2006, 26(12):6-12.Yang Xiaoxian, Zheng Tao, Zhang Baohui, et al.Measurement and research of channel transmission properties on 10 kV medium voltage power lines, part 2:path loss[J].Electric Power Automation Equipment, 2006, 26(12):6-12(in Chinese).
[10]
Galli S, Banwell T.A novel approach to the modeling of the indoor power line channel, part II:transfer function and its properties[J].IEEE Transactions on Power Delivery, 2005, 20(3):1869 -1878.
[11]
Tran-Anh T, Auriol P, Tran-Quoc T.High frequency power transformer modeling for power line communication applications[C]//Power Systems Conference and Exposition.Atlanta, USA:IEEE, 2006: 1069-1074.
[12]
Cataliotti A, Cosentino V, Di Cara D, et al.Oil-filled MV/LV power-transformer behavior in narrow-band power-line communication systems[J].IEEE Transactions on Instrumentation and Measurement, 2012, 61(10):2642-2652.
[13]
Gustavsen B.Frequency-dependent modeling of power transformers with ungrounded windings[J].IEEE Transactions on Power Delivery, 2004, 19(3):1328-1334.
[14]
Andrieu C, Dauphant E, Boss D.A frequency-dependant model for a MV/LV transformer[C]//International Conference on Power Systems Transients.Budapest, Hungary:National Committee for Technological Development (OMFB) - Hungary, 1999:468-473.
[15]
Hardy M E, Ardalan S, O’Neal J B Jr, et al.A model for communication signal propagation on three phase power distribution lines[J].IEEE Transactions on Power Delivery, 1991, 6(3):966-972.
[16]
Lovric D, Boras V, Vujevic S.Accuracy of approximate formulas for internal impedance of tubular cylindrical conductors for large parameters[J].Progress in Electromagnetics Research M, 2011(16):171-184.
[17]
Dommel H W.EMTP theory book[M].USA:Bonneville Power Administration, 1986:64-67.
[18]
Anatory J, Theethayi N, Thottappillil R.Power-line communication channel model for interconnected networks, part II:multiconductor system[J].IEEE Transactions on Power Delivery, 2009, 24(1):124-128.
[19]
Paul R.Analysis of multiconductor transmission lines[M].New York:Wily, 1994:202-204.
[20]
张有兵, 程时杰, 何海波, 等.低压电力线高频载波通信信道的建模研究[J].电力系统自动化, 2002, 26(23):62-66.Zhang Youbing, Cheng Shijie, He Haibo, et al.Modeling of the low-voltage power line used as high frequency carrier communication channel based on experimental results[J].Automation of Electric Power Systems, 2002, 26(23):62-66(in Chinese).
[21]
Hemminger R C, Gale L J, Amoura F, et al.The effect of distribution transformers on distribution line carrier signals[J].IEEE Transactions on Power Delivery, 1987, 2(1):36-40.
[22]
Cataliotti A, Cosentino V, Cara D D, et al.Simulation and laboratory experimental tests of a line to shield medium-voltage power-line communication system [J].IEEE Transactions on Power Delivery, 2011, 26(4):2829-2836.