电站空冷系统变工况性能的数值研究

, PP. 66-73

Keywords: 电站空冷系统,空冷凝汽器,空冷散热器,流动传热性能,背压

Full-Text   Cite this paper   Add to My Lib

Abstract:

无论直接还是间接空冷系统,其热力性能都受到环境气象条件的显著影响。研究不同环境条件,不同机组热负荷和操作条件下机组背压的变化规律,对于电站空冷系统变工况优化运行具有重要参考价值。该文建立了电站空冷系统变工况运行性能的计算模型和数值方法,分别以典型直冷和间冷系统为例,通过数值模拟,获得了不同环境气象条件下,直冷系统空冷凝汽器空气流量和进口空气温度,以及间冷系统空冷散热器空气流量和进口空气温度。以变工况数值计算为基础,分析了直接和间接空冷机组背压的变化规律。结果表明,直接空冷系统热力性能随风速和风向发生显著变化,并随风速增加而降低,导致机组背压随风速增加而升高。对于间接空冷系统,其热力性能先随风速增加而降低,随后又增加,使机组背压呈现先升后降的变化趋势。电站空冷系统变工况性能的数值研究结果,可用于指导空冷系统的优化设计和安全运行。

References

[1]  马义伟. 发电厂空冷技术的现状与进展[J]. 电力设备, 2006,7(3):5-7. Ma Yiwei.Present status and prospect of utility air cooling technology[J].Electrical Equipment,2006,7(3)
[2]  Tawney R,Khan Z,Zachary J. Economic and performance evaluation of heat sink options in combined cycle applications[J]. Journal of Engineering for Gas Turbines and Power, 2005,127(2):397-403.
[3]  van Rooyen J A,Kroger D G. Performance trends of an Air-cooled steam condenser under windy conditions [J]. Journal of Engineering for Gas Turbines and Power, 2008,130(2):023006.
[4]  Hotchkiss P J,Meyer C J,von Backstrom T W. Numerical investigation into the effect of cross-flow on the performance of axial flow fans in forced draught air- cooled heat exchangers[J]. Applied Thermal Engineering, 2006,26(2-3):200-208.
[5]  Duvenhage K,Kroger D G. The influence of wind on the performance of forced draught air-cooled heat exchangers [J]. Journal of Wind Engineering and Industrial Aerodynamics, 1996,62(2-3):259-277.
[6]  Bredell J R,Kroger D G,Thiart G D. Numerical investigation of fan performance in a forced draft air-cooled steam condenser[J]. Applied Thermal Engineering, 2006,26(8-9):846-852.
[7]  Yang L J,Du X Z,Yang Y P. Space characteristics of the thermal performance for air-cooled condensers at ambient winds[J]. International Journal of Heat and Mass Transfer, 2011,54(15-16):3109-3119.
[8]  Yang L J,Du X Z,Yang Y P. Wind effect on the thermo-flow performances and its decay characteristics for air-cooled condensers in a power plant[J]. International Journal of Thermal Sciences, 2012(53):175-187.
[9]  高玉忠. 电站直接空冷凝汽器变工况计算与特性分析[J]. 上海汽轮机, 2001(3):5-7. Gao Yuzhong.Variable condition calculation and features analysis for direct air cooled condenser of power plant [J].Shanghai Turbine,2001(3)
[10]  张春雨,严俊杰,林万超. 海勒式间接空冷系统变工况特性理论研究[J]. 工程热物理学报, 2004,25(1):13-16. Zhang Chunyu,Yan Junjie,Lin Wanchao.A theoretical study on part load operation performance of Heller indirect air-cooled system[J].Journal of Engineering Thermophysics,2004,25(1)
[11]  郝满晋,涂光备,陈冠益,等. 海勒式空冷系统接入附加冷却变工况分析[J]. 工程热物理学报, 2008,29(10):1636-1640. Hao Manjin,Tu Guangbei,Chen Guanyi,et al.Analysis on part load operation performance of Heller indirect air-cooled system with adjunctive cooled system [J].Journal of Engineering Thermophysics,2008,29(10)
[12]  张春雨,严俊杰,李秀云,等. 哈蒙式间接空冷系统变工况特性的理论研究[J]. 动力工程, 2000,20(1):566-570. Zhang Chunyu,Yan Junjie,Li Xiuyun,et al.Theoretical research on part load operation performance of Hamon indirect air-cooled system[J].Power Engineering,2000,20(1)
[13]  Yang L J,Du X Z,Yang Y P. Influences of wind-break wall configurations upon flow and heat transfer characteristics of air-cooled condensers in a power plant [J]. International Journal of Thermal Sciences, 2011,50(10):2050-2061.
[14]  Su M D,Tang G F,Fu S. Numerical simulation of fluid flow and thermal performance of a dry-cooling tower under cross wind condition[J]. Journal of Wind Engineering and Industrial Aerodynamics, 1999,79(3):289-306.
[15]  du Preez A F,Kroger D G. The effect of the heat exchanger arrangement and wind-break walls on the performance of natural draft dry-cooling towers subjected to cross-winds[J]. Journal of Wind Engineering and Industrial Aerodynamics, 1995,58(3):293-303.
[16]  Zhai Z,Fu S. Improving cooling efficiency of dry-cooling towers under cross-wind conditions by using wind-break methods[J]. Applied Thermal Engineering, 2006,26(10):1008-1017.
[17]  Goodarzi M. A proposed stack configuration for dry cooling tower to improve cooling efficiency under crosswind[J]. Journal of Wind Engineering and Industrial Aerodynamics, 2010,98(12):858-863.
[18]  严俊杰,张春雨,李秀云,等. 直接空冷系统变工况特性的理论研究[J]. 热能动力工程, 2000,15(6):601-603. Yan Junjie,Zhang Chunyu,Li Xiuyun,et al.Theoretical research on the off-design performance of a direct air-cooled system[J].Journal of Engineering for Thermal Energy and Power,2000,15(6)
[19]  杨立军,杜小泽,杨勇平,等. 火电站直接空冷凝汽器性能考核评价方法[J]. 中国电机工程学报, 2007,27(2):59-63. Yang Lijun,Du Xiaoze,Yang Yongping,et al.Performance evaluation for direct air-cooled steam condensers in power plant[J].Proceedings of the CSEE,2007,27(2)
[20]  杨立军,杜小泽,杨勇平. 空冷凝汽器全工况运行特性分析[J]. 中国电机工程学报, 2008,28(8):24-28. Yang Lijun,Du Xiaoze,Yang Yongping.Performance analysis of air-cooled condensers at all operating conditions[J].Proceedings of the CSEE,2008,28(8)

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133