全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

热老化时间及测试温度对油纸绝缘时域介电特性的影响

, PP. 162-169

Keywords: 油纸绝缘,时域介电响应,热老化时间,测试温度,特征参量,标准主曲线

Full-Text   Cite this paper   Add to My Lib

Abstract:

为研究热老化时间及测试温度对油纸绝缘时域介电特性的影响,以及更好地应用时域介电响应技术评估变压器油纸绝缘老化状态,首先进行了不同热老化时间及不同测试温度下油纸绝缘绕组模型的极化/去极化电流(polarizationanddepolarizationcurrent,PDC)测试,然后通过扩展Debye模型实现时域介电测试技术间转换,深入研究了热老化时间及测试温度对时域介电特性及其特征参量的影响,最后提出运用时间及幅值平移因子构造电流标准主曲线以消除测试温度对时域介电特性影响的方法。结果表明:油纸绝缘时域介电特性及特征参量受热老化时间及测试温度影响较大;在应用时域介电响应技术评估变压器油纸绝缘状态时,必须考虑测试温度的影响,否则将导致评估结果失实;通过本文方法绘制的电流标准主曲线不仅能消除测试温度对时域介电特性的影响,还能实现在不额外延长实际测试时间的前提下,获得更多反映油纸绝缘状态的时域介电响应信息,并通过实验验证该方法的有效性。

References

[1]  廖瑞金,杨丽君,孙才新,等.基于局部放电主成分因子向量的油纸绝缘老化状态统计分析[J].中国电机工程学报,2006,26(14):114-119.Liao Ruijin,Yang Lijun,Sun Caixin,et al.Aging condition assessment of oil-paper based on principal component and factor analysis of partial discharge [J].Proceedings of the CSEE,2006,26(14):114-119(in Chinese).
[2]  速水敏幸.电力设备的绝缘诊断[M].北京:科学出版社,2003:30-34.Hayami T.Insulation diagnosis of electrical equipment [M].Beijing:Science Press,2003:30-34(in Chinese).
[3]  杨丽君,廖瑞金,孙会刚,等.油纸绝缘热老化特性及生成物的对比分析[J].中国电机工程学报,2008,28(22):53-58.Yang Lijun,Liao Ruijin,Sun Huigang,et al.Contrasting analysis and investigation on properties and products of oil-paper during thermal aging process[J].Proceedings of the CSEE,2008,28(22):53-58(in Chinese).
[4]  杨丽君,廖瑞金,孙才新,等.油纸绝缘老化阶段的多元统计分析[J].中国电机工程学报,2005,25(18):151-156.Yang Lijun,Liao Ruijin,Sun Caixin,et al.Using multivariate statistical method to recognize different aging states of oil-paper[J].Proceedings of the CSEE,2005,25(18):151-156(in Chinese).
[5]  Saha T K.Review of modern diagnostic techniques for assessing insulation condition in aged transformers [J].IEEE Transactions on Dielectrics and Electrical Insulation,2003,10(5):903-917.
[6]  Kuang Y C,Chen G,Jarman P.Recovery voltage measurement on oil-paper insulation with simple geometry and controlled environment[C]//Proceedings of the 2004 IEEE International Conference on Solid Dielectrics.Toulouse,France:IEEE Dielectric and Electrical Insulation Society,2004:739-742.
[7]  Saha T K,Purkait P.Investigation of polarization and depolarization current measurements for the assessment of oil-paper insulation of aged transformers[J].IEEE Transactions on Dielectrics and Electrical Insulation,2004,11(1):144-154.
[8]  Roongroj C,Pattanadech N,Praisuwanna P,et al.Equivalent circuit approximation of transformer insulation by using PDC measurement[C]//5th International Conference on Electrical Engineering/ Electronics, Computer, Telecommunications and Information Technology.Dhaka,Bangladesh:Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology Association,2008:925-928.
[9]  Farahani M,Borsi H,Gockenbach E.Dielectric response studies on insulating system of high voltage rotating machines[J].IEEE Transactions on Dielectrics and Electrical Insulation,2006,13(2):383-393.
[10]  Soltani R,David E,Lamarre L.Impact of humidity on dielectric response of rotating machines insulation system[J].IEEE Transactions on Dielectrics and Electrical Insulation,2010,17(5):1479-1488.
[11]  Wang S Q,Zhang G J,Wei J L,et al.Investigation on dielectric response characteristics of thermally aged insulating pressboard in vacuum and oil-impregnated ambient[J].IEEE Transactions on Dielectrics and Electrical Insulation,2010,17(6):1853-1862.
[12]  Ekanayake C,Gubanski S M,Graczkowski A,et al.Frequency response of oil impregnated pressboard and paper samples for estimating moisture in transformer insulation[J].IEEE Transactions on Power Delivery,2006,21(3):1309-1317.
[13]  Saha T K,Purkait P,Muller F.Deriving an equivalent circuit of transformers insulation for understanding the dielectric response measurements[J].IEEE Transactions on Power Delivery,2005,20(1):149-157.
[14]  Jota P,Islam S M,Jota F G.Modeling the polarization spectrum in composite oil/paper insulation systems [J].IEEE Transactions on Dielectrics and Electrical Insulation,1999,6(2):145-151.
[15]  Setayeshmehr A,Fofana I,Eichler C,et al.Dielectric spectroscopic measurements on transformer oil-paper insulation under controlled laboratory conditions[J].IEEE Transactions on Dielectrics and Electrical Insulation,2008,15(4):1100-1111.
[16]  Yao Z T,Saha T K.Analysis and modeling of dielectric responses of power transformer insulation[C]//Power Engineering Society Summer Meeting.Brisbane,Australia:IEEE Power Engineering Society,2002:417-421.
[17]  Birlasekaran S,Ledwich G,Matthew J.Relaxation studies to identify aging with oil filled transformers- experiments[C]//Proceedings of the 9th International Conference on Properties and Applications of Dielectric Materials.Harbin,China:IEEE Dielectric and Electrical Insulation Society,2009:301-306.
[18]  Osvath P,Zahn H.Polarization spectrum analysis for diagnosis of oil/paper insulation systems[C]//Nordic Insulation Symposium.Vaasa,Finland:IEEE Dielectric and Electrical Insulation Society,1994:155-161.
[19]  Zaengl W S.Dielectric spectroscopy in time and frequency domain for HV power equipment.I.Theoretical considerations[J].IEEE Transactions on Electrical Insulation Magazine,2003,19(5):5-19.
[20]  张良莹,姚熹.电介质物理[M].西安:西安交通大学出版社,1991:243-351.Zhang Liangying,Yao Xi.Dielectric physics[M].Xi’an:Xi’an Jiaotong University Press,1991:243-351(in Chinese).
[21]  Kozlovskis A,Rozenkrons J.Temperature dependence of return voltage characteristics[J].IEEE Transactions on Power Delivery,1999,14(3):705-708.
[22]  Alwis K G N C,Burgoyne C J.Time-temperature superposition to determine the stress-rupture of aramid fibres[J].Applied Composite Materials,2006,13(4):249-264.
[23]  Urzhumtsev Y S.Time-temperature superposition.Review [J].Mechanics of composite materials,1975,11(1):57-72.
[24]  Du Y,Zahn M,Lesieutre B C,et al.Moisture equilibrium in transformer paper-oil systems[J].IEEE Transactions on Electrical Insulation Magazine,1999,15(1):11-20.

Full-Text