间接空冷塔部分冷却扇段关闭热力特性的数值研究

DOI: 10.13334/j.0258-8013.pcsee.2015.18.014, PP. 4682-4689

Keywords: 空冷塔,流量分配,数值模拟,侧风,热力性能

Full-Text   Cite this paper   Add to My Lib

Abstract:

以某600MW机组大型间接空冷塔为对象,分别建立了塔内循环水流量分配模型与空冷塔数值计算模型,针对冷却扇段全部投运、侧面扇段关闭和迎风扇段关闭这3种模式下,侧风对空冷塔热力性能的影响进行了数值模拟。结果表明,在小风速下,关闭侧面或迎风扇段后,其他扇段散热量较扇段全部投运时增加,而扇段内循环水温降有所下降。在大风速下,受塔内外复杂流场及扇段间相互作用的影响,扇段热力性能的变化不尽相同。综合空冷塔冷却效率和防冻需求,为机组经济安全运行提供了参考。

References

[1]  Du Preez A F,Kröger D G.Effect of wind on performance of a dry-cooling tower[J].Heat Recovery Systems and CHP,1993,13(2):139-146.
[2]  丁尔谋.发电厂空冷技术[M].北京:水利电力出版社, 1992:18.Ding Ermou.Air cooling techniques in power plants [M].Beijing:Water and Electric Power Press, 1992:18(in Chinese).
[3]  杜小泽,杨立军,金衍胜,等.火电站直接空冷凝汽器传热系数实验关联式[J].中国电机工程学报, 2008,28(14):32-37.Du Xiaoze,Yang Lijun,Jin Yansheng,et al.Development of experimental correlation for heat transfer coefficient of direct air-cooled condenser in power plant[J].Proceedings of the CSEE,2008,28(14):32-37(in Chinese).
[4]  杨建国,张海珍.直接空冷凝汽器单排翅片管换热性能试验研究[J].中国电机工程学报,2012,32(35):74-79.Yang Jianguo,Zhang Haizhen.Experimental research on heat transfer performance for finned-tubes of direct air-cooled condensers[J].Proceedings of the CSEE,2012,32(35):74-79(in Chinese).
[5]  胡琳,李占斌,何晓嫒.空冷机组设计中典型气象年的选取[J].中国电机工程学报,2009,29(35) :54-58.Hu Lin,Li Zhanbin,He Xiaoyuan.Selection of typical meteorological year in air cooling unit design [J].Proceedings of the CSEE,2009,29(35):54-58(in Chinese).
[6]  Su M D,Tang G F,Fu S.Numerical simulation of fluid flow and thermal performance of a dry-cooling tower under cross wind condition[J].Journal of Wind Engineering and Industrial Aerodynamics,1999, 79(3):289-306.
[7]  杨立军,贾思宁,卜永东,等.电站间冷系统空冷散热器翅片管束流动传热性能的数值研究[J].中国电机工程学报,2012,32(32):50-57.Yang Lijun,Jia Sining,Bu Yongdong,et al.Numerical study on flow and heat transfer characteristics of finned tube bundles for air-cooled heat exchangers of indirect dry cooling systems in power plants[J].Proceedings of the CSEE,2012,32(32):50-57(in Chinese).
[8]  Wei Q D,Zhang B Y,Liu K Q,et al. A study of the unfavorable effects of wind on the cooling efficiency of dry cooling towers[J].Journal of Wind Engineering and Industrial Aerodynamics,1995,54:633-643.
[9]  Yang L J,Wu X P,Du X Z,et al.Dimensional characteristics of wind effects on the performance of indirect dry cooling system with vertically arranged heat exchanger bundles[J].International Journal of Heat and Mass Transfer,2013,67:853-866.
[10]  Hooman K.Dry cooling towers as condensers for geothermal power plants[J].International Communications in Heat and Mass Transfer,2010,37(9):1215-1220.
[11]  Goodarzi M.A proposed stack configuration for dry cooling tower to improve cooling efficiency under crosswind[J].Journal of Wind Engineering and Industrial Aerodynamics, 2010, 98(12):858-863.
[12]  卜永东,杨立军,杜小泽,等.电站空冷系统变工况性能的数值研究[J].中国电机工程学报,2012, 32(35):66-73.Bu Yongdong,Yang Lijun,Du Xiaoze,et al.A numerical approach to off-design performance of dry cooling systems in power plants[J].Proceedings of the CSEE,2012,32(35):66-73(in Chinese).
[13]  西北电力设计院.电力工程水务设计手册[M].北京:中国电力出版社,2005:403-445.Northwest Electricity Designing Institute.Water design manual of power engineering[M].Beijing:China Electric Power Press,2005:403-445(in Chinese).
[14]  国世友,周振伟,刘春生.用风廓线指数律模拟风速随高度变化[J].黑龙江气象,2008, 25(增刊) :20-22.Guo Shiyou,Zhou Zhenwei,Liu Chunsheng.A study of wind velocity varying with altitude by index law of wind profile[J].Heilongjiang Meteorology,2008,25(S1):20-22 (in Chinese).
[15]  Al-Waked R,Behnia M.The effect of windbreak walls on the thermal performance of natural draft dry cooling towers[J].Heat Transfer Engineering,2005,26(8):50-62.
[16]  Goodarzi M,Amooie H.A proposed heterogeneous distribution of water for natural draft dry cooling tower to improve cooling efficiency under crosswind[C]// 2012 4th Conference on Thermal Power Plants (CTPP). Tehran: IEEE,2012:1-6.
[17]  Yang L J,Chen L,Du X Z,et al.Effects of ambient winds on the thermo-flow performances of indirect dry cooling system in a power plant[J].International Journal of Thermal Sciences,2013,64:178-187.
[18]  Al-Waked R,Behnia M.The performance of natural draft dry cooling towers under crosswind:CFD study [J].International Journal of Energy Research,2004,28(2):147-161.
[19]  Zhai Z,Fu S.Improving cooling efficiency of dry-cooling towers under cross-wind conditions by using wind-break methods[J].Applied Thermal Engineering,2006,26(10):1008-1017.
[20]  李人宪.有限体积法基础[M].北京:国防工业出版社,2008:79-100.Li Renxian.The basis of finite volume method [M].Beijing:National Defence Industry Press,2008:79-100(in Chinese).

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133