基于经验模态分解及维格纳威尔分布的电缆双端故障定位算法

DOI: 10.13334/j.0258-8013.pcsee.2015.16.011, PP. 4086-4093

Keywords: 配电网,双端故障测距,经验模态分解,维格纳威尔分布,本征模态函数

Full-Text   Cite this paper   Add to My Lib

Abstract:

快速准确地得到配电网故障位置,对配电网系统安全稳定运行、快速恢复供电具有重要意义。提出一种基于经验模态分解(empiricalmodedecomposition,EMD)和维格纳威尔分布(WignerVilledistribution,WVD)的电缆双端故障定位方案。通过对测量得到的故障行波进行EMD分解,实现对故障高频成分的提取与噪声的消除。将得到的一阶本征模态函数(intrinsicmodefunction,IMF)进行WVD分离,将故障信号的能量在时间及频率坐标系下表述出来。通过计算故障行波的瞬时能量曲线峰值,确定故障初始行波波头的到达时刻。仿真及实验结果表明,所提方案能够准确地确定故障初始行波波头的到达时刻,使电缆双端行波同步。与需要同步时钟的双端定位方法比较,具有较高的定位精度。在实际工程中有良好的应用前景。

References

[1]  朱文龙,周建中,肖剑,等.独立分量分析-经验模态分解特征提取在水电机组振动信号中的应用[J].中国电机工程学报,2013,33(29):95-101.Zhu Wenlong,Zhou Jianzhong,Xiao Jian,et al.An ICA- EMD feature extraction method and its application to vibration signals of hydroelectric generating units [J].Proceedings of the CSEE,2013,33(29):95-101(in Chinese).
[2]  焦在滨,张梦瑶,何世恩,等.基于频域模型识别的串补线路保护方案[J].中国电机工程学报,2013,33(4):186-193.Jiao Zaibin,Zhang Mengyao,He Shien,et al.A distance protection scheme of series compensated lines based on model identification in frequency domain[J]// Proceedings of the CSEE,2013,33(4):186-193(in Chinese).
[3]  姜博,董新洲,施慎行.基于单相电流行波的配电线路单相接地故障选线方法[J].中国电机工程学报,2014,34(34):6216-6227.Jiang Bo,Dong Xinzhou,Shi Shenxing,et al.A method of single phase to ground fault feeder selection based on single phase current traveling wave for distribution lines[J].Proceedings of the CSEE,2014,34(34):6216-6227(in Chinese).
[4]  唐金锐,尹项根,张哲,等.零模检测波速度的迭代提取及其在配电网单相接地故障定位中的应用[J].电工技术学报,2013,28(4):202-211.Tang Jinrui,Yin Xianggen,Zhang Zhe,et al.Iterative extraction of detected zero-mode wave velocity and its application in single phase-to-ground fault location in distribution networks[J].Transactions of China Electrotechnical Society,2013,28(4):202-211(in Chinese).
[5]  梁睿,靳征,王崇林,等.行波时频复合分析的配电网故障定位研究[J].中国电机工程学报,2013,33(28):130-136.Liang Rui,Jin Zheng,Wang Chonglin,et al.Research of fault location in distribution networks based on integration of travelling wave time and frequency analysis[J].Proceedings of the CSEE,2013,33(28):130-136(in Chinese).
[6]  张俊民,周小猛,魏娟,等.基于小波变换的导线绝缘故障定位方法[J].电工技术学报,2012,27(5):99-104.Zhang Junmin,Zhou Xiaomeng,Wei Juan,et al.Method of wire insulation fault location based on wavelet transform[J].Transactions of China Electrotechnical Society,2012,27(5):99-104(in Chinese).
[7]  周鑫,吕飞鹏,吴飞,等.基于小波变换的 T 型线路故障测距新算法[J].电力系统保护与控制,2010,38(2):8-11,33.Zhou Xin,Lü Feipeng,Wu Fei,et al.A new fault location method for T-connection transmission lines based on wavelet transform[J].Power System Protection and Control,2010,38(2):8-11,33(in Chinese).
[8]  杨江天,赵明元.改进双谱和经验模态分解在牵引电机轴承故障诊断中的应用[J].中国电机工程学报,2012,32(18):116-122.Yang Jiangtian,Zhao Mingyuan.Fault diagnosis of traction motor bearings using modified bispectrum and empirical mode decomposition[J].Proceedings of the CSEE,2012,32(18):116-122(in Chinese).
[9]  索南加乐,许文宣,何世恩,等.基于双端电气量的串补输电线路故障测距算法[J].中国电机工程学报,2013,33(19):157-164.Suonan Jiale,Xu Wenxuan,He Shien,et al.A fault location algorithm for series compensated transmission lines based on two-end information[J].Proceedings of the CSEE,2013,33(19):186-193(in Chinese).
[10]  李勋,石帅军,龚庆武.采用信赖域法和双端非同步数据的故障测距算法[J].高电压技术,2010,36(2):019.Li Xun,Shi Shuaijun,Gong Qingwu.Transmission line fault location algorithm using trust-region method and two-terminal unsynchronised data[J].High Voltage Engineering,2010,36(2):019(in Chinese).
[11]  桂勋,刘志刚,韩旭东,等.基于高压输电线电压沿线分布规律的故障双端测距算法[J].中国电机工程学报,2009,29(19):63-69.Gui Xun,Liu Zhigang,Han Xudong,et al.An accurate algorithm of two-terminal fault location based on the distribution of line voltage along hv transmission line [J].Proceedings of the CSEE,2009,29(19):63-69(in Chinese).
[12]  Grispino A S,Petracca G O,Dominguez A E.Comparative analysis of wavelet and EMD in the filtering of radar signal affected by brown noise[J].Latin America Transactions,IEEE (Revista IEEE America Latina),2013,11(1):81-85.
[13]  Amarnath M,Praveen Krishna I R.Empirical mode decomposition of acoustic signals for diagnosis of faults in gears and rolling element bearings[J].Science,Measurement & Technology,IET,2012,6(4):279-287.
[14]  Moghtaderi A,Flandrin P,Borgnat P.Time-varying spectrum estimation of uniformly modulated processes by means of surrogate data and empirical mode decomposition[C]// IEEE International Conference on Acoustics Speech and Signal Processing (ICASSP).IEEE,2010:3678-3681.
[15]  Chen G,Chen J,Dong G M.Chirplet Wigner-Ville distribution for time-frequency representation and its application[J].Mechanical Systems and Signal Processing,2013,41(1):1-13.
[16]  Rosero J,Romeral L,Ortega J A,et al.Short circuit fault detection in PMSM by means of empirical mode decomposition (EMD) and Wigner Ville distribution (WVD)[C]// Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition.IEEE,2008:98-103.
[17]  Thomas M,Lethakumary B,Jacob R.Performance comparison of multi-component signals using WVD and Cohen's class variants[C]//IEEE International Conference on Computing,Electronics and Electrical Technologies (ICCEET).IEEE,2012:717-722.
[18]  耶晓东,何亚银.基于伪 Wigner-Ville 分布与小波变换的滚动轴承故障诊断[J].机械设计与研究,2012,28(5):56-58.Ye Xiaodong,He Yayin.Fault diagnosis of roller bearing based on the pseudo Wigner-Ville distribution and wavelet transform[J].Machine Design and Research,2012,28(5):56-58(in Chinese).
[19]  杨世锡,胡劲松,吴昭同,等.旋转机械振动信号基于 EMD 的希尔伯特变换和小波变换时频分析比较[J].中国电机工程学报,2003,23(6):102-107.Yang Shixi,Hu Jingsong,Wu Zhaotong,et al.The comparison of vibration signals’ time-frequency analysis between EMD-based HT and WT method in rotating machinery[J].Proceedings of the CSEE,2003,23(6):102-107(in Chinese).
[20]  张晓明,徐岩,王瑜,等.一种基于参数检测的双 端故障测距算法[J].电力系统保护与控制,2011,39(12):106-111.Zhang Xiaoming,Xu Yan,Wang Yu,et al.A fault location algorithm for two-terminal transmission lines based on parameter detection[J].Power System Protection and Control,2011,39(12):106-111(in Chinese).

Full-Text