一种LCLLC滤波器及其参数设计

DOI: 10.13334/j.0258-8013.pcsee.2015.08.022, PP. 2009-2017

Keywords: LLCL滤波器,LCLLC滤波器,滤波器参数设计,高次谐波

Full-Text   Cite this paper   Add to My Lib

Abstract:

新型高阶LLCL并网逆变器输出滤波器具有一个串联谐振支路,可以旁路开关频率谐波电流,减小电网电流谐波。针对LLCL滤波器二倍及其以上倍开关频率电流谐波衰减速率低的问题,提出一种新的LCLLC型滤波器拓扑;分析所提滤波器的谐振频率特性,并提出滤波器参数的设计方法;通过仿真和实验对LCL、LLCL和LCLLC3种滤波器进行对比,证明所提滤波器不仅能够满足电网对高次谐波的要求,且具有较强的参数鲁棒性。

References

[1]  张兴,张崇巍.PWM整流器及其控制[M].北京:机械工业出版社,2012:1-5. Zhang Xing,Zhang Chongwei.PWM rectifier and it’s control[M].Beijing:China Machine Press,2012:1-5(in Chinese).
[2]  王兆安,黄俊.电力电子技术[M].北京:机械工业出版社,2000:150-165.Wang Zhao’an,Huang Jun.Power electronics[M].Beijing:China Machine Press,2000:150-165(in Chinese).
[3]  郑昕昕,肖岚,王长宝,等.三相变流器LCL滤波器参数优化新方法[J].中国电机工程学报,2013,33(12):55-63. Zheng Xinxin,Xiao Lan,Wang Changbao,et al.A new parameter optimization method of LCL filters in three-phase converters[J].Proceedings of the CSEE,2013,33(12):55-63(in Chinese).
[4]  王要强,吴凤江,孙力,等.阻尼损耗最小化的LCL滤波器参数优化设计[J].中国电机工程学报,2010,30(27):90-95. Wang Yaoqiang,Wu Fengjiang,Sun Li,et al.Optimized design of LCL filter for minimal damping power loss[J].Proceedings of the CSEE,2010,30(27):90-95(in Chinese).
[5]  Park M Y,Chi M H,Park J H,et al.LCL-filter design for grid-connected PCS using total harmonic distortion and ripple attenuation factor[C]//Power Electronics Conference(IPEC),2010 International.IEEE,2010:1688-1694.
[6]  刘虔,彭力,唐诗颖,等.一种基于图解的LCL滤波器设计和优化方法[J].中国电机工程学报,2012,32(36):36-43. Liu Qian,Peng Li,Tang Shiying,et al.A design and optimization method of LCL filters based on the graphic-analysis[J].Proceedings of the CSEE,2012,32(36):36-43(in Chinese).
[7]  IEEE.IEEE Standard 519—1992 IEEE recommended practices and requirements for harmonic control in electrical power systems[S].1992.2014-01-07.
[8]  IEEE.IEEE Standard 1547.2—2008 IEEE standard for interconnecting distributed resources with electric power systems[S].2008.2014-01-07.
[9]  Wu W,He Y,Blaabjerg F.An LLCL power filter for single-phase grid-tied inverter[J].IEEE Transactions on Power Electronics,2012,27(2):782-789.
[10]  Wu W,He Y,Tang T,et al.A new design method for the passive damped LCL and LLCL filter-based single-phase grid-tied inverter[J].IEEE Transactions on Industrial Electronics,2013,60(10):4339-4350.
[11]  Wu W,Huang M,Sun Y,et al.A composite passive damping method of the LLCL-filter based grid-tied inverter[C]//2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems(PEDG).IEEE,2012:759-766.
[12]  Wu W,Sun Y,Huang M,et al.A robust passive damping method for LLCL filter based grid-tied inverters to minimize the effect of grid harmonic voltages[J].IEEE Transactions on Power Electronics,2014,29(7):3279-3289.
[13]  Liu C,Dai K,Duan K,et al.Application of an LLCL filter on three-phase three-wire shunt active power filter[C]// 2012 IEEE 34th International Telecommunications Energy Conference.IEEE,2012:1-5.
[14]  Wu W,Sun Y,Lin Z,et al.A modified LLCL-filter with the reduced conducted EMI noise[C]//2013 15th European Conference on Power Electronics and Applications(EPE).IEEE,2013:1-10.
[15]  Parikshith C,Vinod J.Filter optimization for grid interactive voltage source inverters[J].IEEE Transactions on Industrial Electronics,2010,57(12):4106-4114.
[16]  Liserre M,Blaabjerg F,Dell Aquila A. Step-by-step design procedure for a grid-connected three-phase PWM voltage source converter[J].International journal of electronics,2004(91):445-460.
[17]  Bao Chenlei,Ruan Xinbo,Wang Xuehua,et al.Step-by-step controller design for LCL-type grid- connected inverter with capacitor-current-feedback active-damping[J].IEEE Transactions on Power Electronics,2014,29(3):1239-1253.
[18]  刘飞,查晓明,段善旭.三相并网逆变器LCL滤波器的参数设计与研究[J].电工技术学报,2010,25(3):110-116. Liu Fei,Zha Xiaoming,Duan shanxu.Design and research on parameter of LCL filter in three-phase grid-connected inverter[J].Transactions of China Electrotechnical Society,2010,25(3):110-116(in Chinese).
[19]  Ricchiuto D,Liserre M,Kerekes,et al.Robustness analysis of active damping methods for an inverter connected to the grid with an LCL-filter[C]//Energy Conversion Congress and Exposition (ECCE).IEEE,2011:2028-2035.
[20]  Mohamed Y,Rahman M, Y A I,et al.Robust line-voltage sensorless control and synchronization of LCL-filtered distributed generation inverters for high power quality grid connection[J].IEEE Transactions on Power Electronics,2012,27(1):87-98.