一种二极管无源钳位的单相无变压器型光伏并网逆变拓扑研究

DOI: 10.13334/j.0258-8013.pcsee.2015.06.021, PP. 1455-1462

Keywords: 并网逆变器,漏电流,共模电压,寄生电容,二极管无源钳位

Full-Text   Cite this paper   Add to My Lib

Abstract:

提出一种基于二极管无源钳位思想的单相无变压器型光伏并网逆变器拓扑。与H5等传统电路相比,本拓扑具有更好的对地漏电流抑制能力。目前主流的单相无变压器型逆变电路普遍采用直流或交流解耦技术,阻断共模电流的流通路径。但是,功率开关上的寄生电容可能与共模电抗形成谐振回路,使得共模电流无法彻底消除。以H5拓扑为例,定量分析功率器件寄生电容影响共模电流的机理。针对这一问题,引入无源二极管钳位电路,使得共模电压被母线电容中点钳位,从而抑制了功率器件寄生电容引起的共模电压振荡,更有效地消除对地漏电流。在理论和仿真分析的基础上,通过搭建2kW实验平台验证所提拓扑的性能。结果表明,改进拓扑相对于原拓扑而言,能更好地抑制对地漏电流,提高了无变压器型光伏并网系统的安全裕度。

References

[1]  王丛,惠晶.一种新型单相非隔离光伏并网逆变器[J].电力电子技术,2013,47(4):61-63.Wang Cong,Hui Jing.New single-phase uninsulated photovoltaic grid-connected inverter[J].Power Electronics,2013,47(4):61-63(in Chinese).
[2]  艾欣,韩晓男,孙英云.光伏发电并网及其相关技术发展现状与展望[J].现代电力,2013,30(1):1-7.Ai Xin,Han Xiaonan,Sun Yingyun.The development status and prospect of grid-connected photovoltaic generation and its relater technologies[J].Morden Electric Power,2013,30(1):1-7(in Chinese).
[3]  Kjaer S B,Pedersen J K,Blaabjerg F.A review of single-phase grid-connected inverters for photovoltaic modules[J].IEEE Transactions on Industry Applications,2005,41(5):1292-1306.
[4]  嵇保健,洪峰,赵剑锋.一种不隔离三电平双Buck光伏并网逆变器[J].中国电机工程学报,2012,32(12):7-13.Ji Baojian,Hong Feng,Zhao jianfeng.A non-isolated three-level dual buck photovoltaic grid-connected inverter[J].Proceedings of the CSEE,2012,32(12):7-13(in Chinese).
[5]  Calais M,Agelidis V G,Meinhardt M.Multilevel converters for single-phase grid connected photovoltaic systems:an overview[J].Solar energy,1999,66(5):325-335.
[6]  Blaabjerg F,Chen Z,Kjaer S B.Power electronics as efficient interface in dispersed power generation systems[J].IEEE Transactions on Power Electronics,2004,19(5):1184-1194.
[7]  肖华锋,谢少军,陈文明,等.非隔离型光伏并网逆变器漏电流分析模型研究[J].中国电机工程学报,2010,30(18):9-14.Xiao Huafeng,Xie Shaojun,Chen Wenming,et al.Study on leakage current model for transformerless photovoltaic grid-connected inverter[J].Proceedings of the CSEE,2010,30(18):9-14(in Chinese).
[8]  肖华锋,杨晨,谢少军.NPC三电平并网逆变器共模电流抑制技术研究[J].中国电机工程学报,2010,30(33):23-29.Xiao Huafeng,Yang Chen,Xie Shaojun.NPC three-level grid-connected inverter with leakage current suppression[J].Proceedings of the CSEE,2010,30(33):23-29(in Chinese).
[9]  邬伟扬,郭小强.无变压器非隔离型光伏并网逆变器漏电流抑制技术[J].中国电机工程学报,2012,32(18):1-8.Wu Weiyang,Guo Xiaoqiang.A review of novel leakage current suppression techniques for transformerless photovoltaic inverters[J].Proceedings of the CSEE,2012,32(18):1-8(in Chinese).
[10]  马琳,金新民.无变压器结构光伏并网系统共模漏电流分析[J].太阳能学报,2009,30(7):883-888.Ma Lin,Jin Xinming.Analyies on common-mode leakage current of transformerless photovoltaic grid-connected system[J].Acta Energiae Solaris Sinica,2009,30(7):883-888(in Chinese).
[11]  张兴,孙龙林,许颇,等.单相非隔离型光伏并网系统中共模电流抑制的研究[J].太阳能学报,2009(9):1202-1208.Zhang Xing,Sun Longlin,Xu Po,et al.Study on common-mode current suppression of single-phase non-isolated photovoltaic system[J].Acta Energiae Solaris Sinica,2009(9):1202-1208(in Chinese).
[12]  Yang B,Li W,Gu Y,et al.Improved transformerless inverter with common-mode leakage current elimination for a photovoltaic grid-connected power system[J].IEEE Transactions on Power Electronics,2012,27(2):752-762.
[13]  Araújo S V,Zacharias P,Mallwitz R.Highly efficient single-phase transformerless inverters for grid-connected photovoltaic systems[J].IEEE Transactions on Industrial Electronics,2010,57(9):3118-3128.
[14]  Xiao H,Xie S,Chen Y,et al.An optimized transformerless photovoltaic grid-connected inverter[J].IEEE Transactions on Industrial Electronics,2011,58(5):1887-1895.
[15]  Victor M,Greizer F,Bremicker S,et al.Method of converting a direct current voltage from a source of direct current voltage,more specifically from a photovoltaic source of direct current voltage,into a alternating current voltage:U.S.Patent 7,411,802[P].2008-8-12.
[16]  Schmidt H,Siedle C,Ketterer J.Inverter for transforming a DC voltage into an AC current or an AC voltage:Germany,EP 1369985(A2)[P].2003-12-10.
[17]  张犁,孙凯,冯兰兰,等.一种低漏电流六开关非隔离全桥光伏并网逆变器[J].中国电机工程学报,2012,32(15):1-7.Zhang Li,Sun Kai,Feng Lanlan,et al.H6 non-isolated full bridge grid-connected PV inverters with low leakage currents[J].Proceedings of the CSEE,2012,32(15):1-7(in Chinese).
[18]  Cui W,Yang B,Zhao Y,et al.A novel single-phase transformerless grid-connected inverter[C]//IECON 2011-37th Annual Conference on IEEE Industrial Electronics Society.IEEE,2011:1126-1130.
[19]  González R,López J,Sanchis P,et al.Transformerless inverter for single-phase photovoltaic systems[J].IEEE Transactions on Power Electronics,2007,22(2):693-697.
[20]  DKE Deutsche Kommission Elektrotechnik Elektronik Informationstechnik im DIN und VDE.DIN VDE 0126-1-1 Selbsttätig Wirkende Schaltstelle[S].Berlin:vde Verlag,2013:7-8.https://www.vde-verlag.de/standards/0100178/ din-vde-v-0126-1-1-vde-v-0126-1-1-2013-08.html.
[21]  Zhang L,Sun K,Feng L,et al.A family of neutral point clamped full-bridge topologies for transformerless photovoltaic grid-tied inverters[J].IEEE Transactions on Power Electronics,2013,28(2):730-739.
[22]  张犁,孙凯,冯兰兰,等.中点钳位非隔离全桥光伏并网逆变器[J].中国电机工程学报,2012,32(18):16-22.Zhang Li,Sun Kai,Feng Lanlan,et al.Neutral point clamped non-isolated full bridge pv grid-connected inverters[J].Proceedings of the CSEE,2012,32(18):16-22(in Chinese).
[23]  肖华锋,杨晨,谢少军.基于改进型全桥电路的非隔离光伏并网逆变器[J].中国电机工程学报,2011,31(3):40-46.Xiao Huafeng,Yang Chen,Xie Shaojun.A transformerless PV grid-connected inverter based on improved full bridge topology[J].Proceedings of the CSEE,2011,31(3):40-46(in Chinese).
[24]  Xiao H,Xie S,Chen Y,et al.An optimized transformerless photovoltaic grid-connected inverter[J].IEEE Transactions on Industrial Electronics,2011,58(5):1887-1895.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133