Boteler D H.Geomagnetic hazards to conducting networks[J].Natural Hazards,2003,28(2-3):537-561.
[2]
Kappenman J G.Storm sudden commencement events and the associated geomagnetically induced current risks to ground-based systems at low-latitude and midlatitude locations[J].Space Weather,2003,1(3):1016.
[3]
NERC.High-Impact,Low-Frequency Event Risk to the North American Bulk Power System[R/OL].NERC,Princeton,New Jersey,U.S.A.,2010. http://www.nerc. com/files/HILF-060210.pdf.
[4]
NERC.2012 Special reliability assessment interim report-effects of geomagnetic disturbances on the bulk power system[R/OL].North American Electric Reliability Corporation,2012[2012-02-.http://www.nerc.com/ pa/RAPA/ra/Pages/default.aspx.
[5]
Koen J,Gaunt T.Geomagnetically induced currents in the Southern African electricity transmission network[C]// Proceedings of IEEE Bologna Technology Conference.Bologna,Italy:IEEE,2003:1-7.
[6]
Beland J,Small K.Space weather effects on power transmission systems:the cases of hydro-québec and transpower New ZealandLtd[M].Springer Netherlands,2005:287-299.
[7]
Marshall R A,Smith E A,Francis M J,et al.A preliminary risk assessment of the Australian region power network to space weather[J].Space Weather,2011,9(10):S10004, 1-18.
[8]
刘连光,刘春明,张冰,等.我国广东电网几次强磁暴影响事件[J].地球物理学报,2008,51(4):976-981. Liu Lianguang,Liu Chumming,Zhang Bing,et al.Strong magnetic storm’s influence on China’s Guangdong power grid[J].Chinese J.Geophysics,2008,51(4):976-981(in Chinese).
[9]
Torta J M,Serrano L,Regué J R,et al.Geomagnetically induced currents in a power grid of northeastern Spain[J].Space Weather,2012,10(6).S06002:1-29.
[10]
Beggan C D,Beamish D,Richards A,et al.Prediction of extreme geomagnetically induced currents in the UK high-voltage network[J].Space Weather,2013,11(7):407-419.
[11]
Erinmez I A,Kappenman J G,Radasky W A.Management of the geomagnetically induced current risks on the national grid company's electric power transmission system[J].Journal of Atmospheric and Solar-Terrestrial Physics,2002,64(5):743-756.
[12]
Thomson A W P,Gaunt C T,Cilliers P,et al.Present day challenges in understanding the geomagnetic hazard to national power grids[J].Advances in Space Research,2010,45(9):1182-1190.
[13]
Vijapurapu,Sivarama Karthik.Contingency analysis of power systems in presence of geomagnetically induced currents[R/OL].University of Kentucky.2013.http:// uknowledge.uky.edu/ece_etds/32.
[14]
刘连光,吴伟丽.磁暴影响电力系统安全风险评估思路与理论框架[J].中国电机工程学报,2014,34(10):1583-1591. Liu Lianguang,Wu Weili.Security risk assessment ideas and theoretical framework for power system considering geomagnetic storm[J].Proceedings of the CSEE,2014,34(10):1583-1591(in Chinese).
[15]
Pulkkinen A,Bernabeu E,Eichner J,et al.Generation of 100-year geomagnetically induced current scenarios[J].Space Weather,2012,10(4):S04003,1-37.
[16]
Kappenman J.Geomagnetic storms and their impacts on the U.S.Power Grid[R].Metatech Corporation Report Meta-R-319,2010:25-60.
[17]
Overbye T J,Hutchins T R,Shetye K,et al.Integration of geomagnetic disturbance modeling into the power flow:A methodology for large-scale system studies[C]// North American Power Symposium (NAPS).Champaign,IL:IEEE,2012:1-7.
[18]
Price P R.Geomagnetically induced current effects on transformers[J].IEEE Transactions on Power Delivery,2002,17(4):1002-1008.
[19]
李泓志,崔翔,刘东升,等.直流偏磁对三相电力变压器的影响[J].电工技术学报,2010,25(5):88-96. Li Gongzhi,Cui Xiang,Liu Dongsheng,et al.Influence on three-phase power transformer by DC bias excitation [J].Transactions of China Electrotechnical Society,2010,25(5):88-96(in Chinese).
[20]
赵志刚,刘福贵,张俊杰,等.直流偏磁条件下变压器励磁电流的实验与分析[J].电工技术学报,2010,25(4):71-76. Zhao Zhigang,Liu Fugui,Zhang Junjie,et al.Measurement and analysis of magnetizing current in DC-biased transformers[J].Transactions of China Electrotechnical Society,2010,25(4):71-76(in Chinese).
[21]
吴伟丽,刘连光.基于稀疏地磁台数据的磁暴感应地电场算法研究[J].空间科学学报,2013,33(6):617-623. Wu Weili,Liu Lianguang.Calculation method for geoelectric field in mid-and low-latitude area based on sparse geomagneticdata[J].Chin. J. Space Sci.,2013,33(6):617-623(in Chinese).
[22]
郑宽,刘连光,Boteler D H,等.多电压等级电网的GIC-Benchmark建模方法[J].中国电机工程学报,2013,33(16):179-186. Zheng Kuan,Liu Lianguang,David H Boteler,et al.Modelling geomagnetically induced currents in multiple voltage levels of a power system illustrated using the GIC-Benchmark case[J].Proceeding of the CSEE,2013,33(16):179-186(in Chinese).
[23]
Bernabeu E.Modeling geomagnetically induced currents in dominion virginia power using extreme 100-year geoelectric field scenarios,Part 1[J].IEEE Transactions on Power Delivery,2013,28(1):516-523.
[24]
Marti L,Rezaei-Zare A,Narang A.Simulation of transformer hotspot heating due to geomagnetically induced currents[J].IEEE Transactions on Power Delivery,2013,28(1):320-327.
[25]
Girgis R,Vedante K.Effects of GIC on power transformers and power systems[C]//IEEE PES Transmission and Distribution Conference and Exposition (T&D).Orlando,FL:IEEE,2012:1-8.
[26]
张雪松,黄莉.基于PSCAD/EMTDC的变压器直流偏磁仿真研究[J].电力系统保护与控制,2012,40(19):78-84. Zhang Xuesong,Huang Li.Simulation analysis of DC magnetic bias induced current of transformer based on PSCAD/EMTDC[J].Power System Protection and Control,2012,40(19):78-84(in Chinese).
[27]
Berge J,Varma R K.Determination of the spectrum of frequencies generated by a saturated transformer[C]//24th Canadian Conference on Electrical and Computer Engineering (CCECE).Niagara Falls,ON:IEEE,2011:001272-001277.
[28]
Girgis R S,Ko C D.Calculation techniques and results of effects of GIC currents as applied to large power transformers[J].IEEE Transactions on Power Delivery,1992,7(2):699-705.
[29]
Kappenman,J G.Geomagnetic storms and their impact on power systems[J].IEEE Power Engineering Review,1996.16(5):5-8.
[30]
Ni M,McCalley J D,Vittal V.Online risk-based security assessment[J].IEEE Trans. on Power Systems,2003,18(1):258-265.
[31]
Thomson A W P,Dawson E B,Reay S J.Quantifying extreme behavior in geomagnetic activity[J].Space Weather,2011,9(10):SW000696,1-21.
[32]
Brodin E,Rootzén H.Univariate and bivariate GPD methods for predicting extreme wind storm losses[J].Insurance:Mathematics and Economics,2009,44(3):345-356.
[33]
Horton R,Boteler D H,Overbye T,et al.A test case for the calculation of geomagnetically induced currents[J].IEEE Transactions on Power Delivery,2012,27(4):2368-2373.
[34]
Liu Lianguang,Wu Weili,Zheng Kuan.Preliminary estimate of GIC risk in China’s Future Power Grid due to geomagnetic disturbance[C]//IEEE Power & Energy Society General Meeting.Vancouver,Canada,2013:1-5.