[1] | Sundaram A. Power quality implications of distribution construction[R]. California:EPRI, 2004.
|
[2] | Yokoyama S. 配电线路雷害对策[M]. 吴国良, 译.北京:中国电力出版社,2008:14-24. Yokoyama S.Lightning damage countermeasures of distribution lines[M].Wu Guoliang, translation.Beijing
|
[3] | Chowdhuri P. Estimation of flashover rates of overhead power distribution lines by lightning strokes to nearby ground[J]. IEEE Transactions on Power Delivery, 1989,4(3):1982-1989.
|
[4] | Eriksson A J,Stringfellow M F,Meal D V. Lightning- induced overvoltages on overhead distribution lines [J]. IEEE Transactions on Power Apparatus and Systems, 1982,PAS-101:960-969.
|
[5] | 文习山,彭向阳,解广润. 架空配电线路感应雷过电压的数值计算[J]. 中国电机工程学报, 1998,18(4):76-78. Wen Xishan,Peng Xiangyang,Xie Guangrun.Numerical calculation of lightning induced voltages on overhead distribution lines[J].Proceedings of the CSEE,1998,18(4)
|
[6] | DL/T 620-1997. 交流电气装置过的电压保护和绝缘配合[S]. 北京:中国电力出版社, 1997.DL/T 620-1997.Overvoltage protection and insulation coordination for AC electrical installations [S].Beijing:ChinaElectric Power Publishing Company,1997(in Chinese).
|
[7] | Society T A D C. IEEE Std 1410-2010 IEEE guide for improving the lightning performance of electric power overhead distribution lines[S]. New York:The Institute of Electrical and Electronics Engineers, Inc,2010.
|
[8] | Chowdhuri P,Gross E T B. Voltage surges induced on overhead lines by lightning strokes[J]. Proceedings of the Institution of Electrical Engineers, 1967,114(12):1899-1907.
|
[9] | Nucci C A,Rachidi F,Ianoz M,et al. Comparison of two coupling models for lightning-induced overvoltage calculations[J]. IEEE Transactions on Power Delivery, 1995,10(1):330-339.
|
[10] | Golde R. Lightning[M]. London:Academic Press, 1977:110-120.
|
[11] | Cooray V. Calculating lightning-induced overvoltages in power lines. A comparison of two coupling models [J].IEEE Transactions on Electromagnetic Compatibility, 1994,36(3):179-182.
|
[12] | Piantini A,Janiszewski J M. Induced voltages on distribution lines due to lightning discharges on nearby metallic structures[J]. IEEE Transactions on Magnetics, 1998,34(5):2799-2802.
|
[13] | Agrawal A K,Price H J,Gurbaxani S H. Transient response of multiconductor transmission lines excited by a nonuniform electromagnetic field[J]. IEEE Transactions on Electromagnetic Compatibility, 1980,22(2):119-129.
|
[14] | Ianoz M,Orzan D,Rachidi F. Validation of field-to- transmission line coupling models[C]//1997 International Symposium on Electromagnetic Compatibility,Beijing,1997.
|
[15] | Nucci C A,Rachidi F,Ianoz M V,et al. Lightning- induced voltages on overhead lines[J]. IEEE Transactions on Electromagnetic Compatibility, 1993,35(1):75-86.
|
[16] | Master M J,Uman M A. Lightning induced voltages on power lines:theory[J]. IEEE Transactions on Power Apparatus and Systems, 1984,103(9):2502-2518.
|
[17] | 文武,阮江军,陈允平,等. 架空传输线在间接雷击作用下负载浪涌的分析[J]. 中国电机工程学报, 2003,23(1):117-121. Wen Wu,Ruan Jiangjun,Chen Yunping,et al.Surge analysis on load of transmission line under indirect lightning strike[J].Proceedings of the CSEE,2003,23(1)
|
[18] | Nucci C A,Mazzetti C,Rachidi F,et al. On lightning return stroke models for LEMP calculations[C]//19th International Conference on Lightning Protection,Graz,Austria,1988.
|
[19] | Heidler F,Cvetic J M,Stanic B V. Calculation of lightning current parameters[J]. IEEE Transactions on Power Delivery, 1999,14(2):399-404.
|
[20] | Rubinstein M. An approximate formula for the calculation of the horizontal electric field from lightning at close,intermediate,and long range[J]. IEEE Transactions on Electromagnetic Compatibility, 1996,38(3):531-535.
|
[21] | Cooray V. Horizontal electric field generated by lightning [J]. Radio Science, 1992(27):529-537.
|
[22] | Tesche F M,Ianoz M,Karlsson T. EMC Analysis Methods and Computational Models[M]. New York:John Wiley & Sons, INC,1997:321-326.
|
[23] | Rachidi F,Loyka S L,Nucci C A,et al. A new expression for the ground transient resistance matrix elements of multiconductor overhead transmission lines[J]. Electric Power Systems Research, 2003,65(1):41-46.
|
[24] | Barker P P,Short T A,Eybert-Berard A R,et al. Induced voltage measurements on an experimental distribution line during nearby rocket triggered lightning flashes[J]. IEEE Transactions on Power Delivery, 1996,11(2):980-995.
|