[1] | 蒋兴良,舒立春,孙才新. 电力系统污秽与覆冰绝缘[M]. 北京:中国电力出版社, 2009:152-153. Jiang Xingliang,Shu Lichun,Sun Caixin.Power system pollution and icing insulation[M].Beijing:ChinaElectric Power Press,2009(in Chinese).
|
[2] | Farzaneh M. Atmospheric icing of power networks[M]. New York:Springer, 2008:356-357.
|
[3] | 申屠刚. 电力系统输电线路抗冰除冰技术研究进展综述[J]. 机电工程, 2008,25(7):72-75. Shen Tugang.Review of development of de-icing methods on transmission lines[J].Mechanical & Electrical Engineering Magazine,2008,25(7)
|
[4] | 蒋兴良,马俊,王少华,等. 输电线路冰害事故及原因分析[J]. 中国电力, 2005,38(11):27-30. Jiang Xingliang,Ma Jun,Wang Shaohua,et al.Transmission lines ice accidents and analysis of the formative factors[J].Electric Power,2005,38(11)
|
[5] | 李庆峰,范峥,吴穹,等. 全国输电线路覆冰情况调研及事故分析[J]. 电网技术, 2008,32(9):33-36. Li Qingfeng,Fan Zheng,Wu Qiong,et al.Investigation of ice-covered transmission lines and analysis on transmission line failures caused by ice-coating in China[J].Power System Technology,2008,32(9)
|
[6] | Fikke S. Modern meteorology and atmospheric icing[C]//Proc 11th International Workshop on Atmospheric Icing of Structures(IWAIS 2005),Montreal,Canada,2005.
|
[7] | Goodwin E J. Predicting ice and snow loads for transmission lines[J]. Proceedings of the First IWAIS, 1983,267-273.
|
[8] | Lee L Y,Nellis C L,Brown J E. 60 Hz tests on ice coated 500kV insulator strings[C]//IEEE/PES Summer Meeting,San Francisco,USA,1975,Paper A75-499-4.
|
[9] | 蒋兴良,王波,张志劲,等. 串长及布置方式对高海拔覆冰绝缘子串直流冰闪电压的影响[J]. 中国电机工程学报, 2008,28(3):1-5. Jiang Xingliang,Wang Bo,Zhang Zhijin,et al.Influence of length and arrangement of iced insulator strings on DC flashover voltage at high altitude districts[J].Proceedings of the CSEE,2008,28(3)
|
[10] | 蒋兴良,卢杰,苑吉河,等. 输电线路绝缘子串防冰闪措施研究[J]. 电网技术, 2008,32(14):19-24. Jiang Xingliang,Lu Jie,Yuan Jihe,et al.Study on measures to prevent icing flashover of insulation strings[J].Power System Technology,2008,32(14)
|
[11] | 蒋兴良,杜辕,林峰,等. 持久性就地成型防污闪复合涂料对绝缘子覆冰及交流冰闪电压的影响[J]. 电网技术, 2008,32(1):71-75. Jiang Xingliang,Du Yuan,Lin Feng,et al.Effect of PRTV on insulator string?s icing and its AC icing flashover voltage[J].Power System Technolgy,2008,32(1)
|
[12] | Sugawara N,Hokari K,Matsuoka R,et al. Insulation properties of iced various insulators during freezing rain and de-icing[C]//Sixth International Symposium on High Voltage Engineering,New Orieans,LA,USA,1989:33-47.
|
[13] | 刘正响,黄长学,马文广,等. 防污增爬裙的研究与实践[J]. 高电压技术, 1997,23(4):56-58. Liu Zhengxiang,Huang Changxue,Ma Wenguang,et al.Research and practical of the composite antipollution shed[J].High Voltage Engineering,1997,23(4)
|
[14] | 杜辕. 采用间插布置的绝缘子串交流覆冰闪络特性研究[D]. 重庆:重庆大学, 2007.Du Yuan.Study on AC flashover performance of iced insulators connected with alternately large and small diameter sheds[D].Chongqing:ChongqingUniversity,2007(in Chinese).
|
[15] | 黄长学,蒋兴良,杜忠东,等. 110 kV防冰闪型复合绝缘子的冰闪特性[J]. 高电压技术, 2009,35(10):2540-2544. Huang Changxue,Jiang Xingliang,Du Zhongdong,et al.Ice flashover characteristics of 110kV anti-icing composite insulator[J].High Voltage Engineering,2009,35(10)
|
[16] | 张志劲,蒋兴良,胡建林,等. 间插布置方式对交流绝缘子串覆冰特性影响[J]. 电工技术学报, 2011,26(1):170-176. Zhang Zhijin,Jiang Xingliang,Hu Jianlin,et al.Influence of the type of insulators connected with alternately large and small diameter sheds on ac icing flashover performance[J].Transactions of China Electrotechnical Society,2011,26(1)
|
[17] | 蒋兴良,卢杰,杜辕,等. 间插布置绝缘子串的交流冰闪特性[J]. 中国电机工程学报, 2009,29(10):12-16. Jiang Xingliang,Lu Jie,Du Yuan,et al.AC flashover performance of iced insulators string structured with alternately large and small diameter sheds[J].Proceedings of the CSEE,2009,29(10)
|
[18] | 王晓峰. 复合绝缘子交流覆冰试验方法[D]. 重庆:重庆大学, 2009.Wang Xiaofeng.Artificial AC Icing Test Method on Composite Insulators[D].Chongqing:ChongqingUniversity,2009(in Chinese).
|
[19] | 胡建林. 低气压下覆冰绝缘子(长)串闪络特性及直流放电模型研究[D]. 重庆:重庆大学, 2009.Hu Jianlin.Study on flashover performance and DC discharge model of ice-covered insulator strings at low air pressure[D].Chongqing:ChongqingUniversity,2009(in Chinese).
|
[20] | 蒋兴良,董冰冰,胡建林,等. 考虑污秽度及伞型结构影响的110kV支柱绝缘子交流闪络电压特性[J]. 高电压技术, 2012,38(8):2037-2043. Jiang Xingliang,Dong bingbing,Hu Jianlin,et al.AC flashover performance of ice-covered 110kV post insulator considering its pollution and shed configuration [J].High Voltage Engineering,2012,38(8)
|
[21] | IEEE Dielectrics and Electrical Insulation Society. IEEE Std. 1783-2009 IEEE guide for test methods and procedures to evaluate the electrical performance of insulators in freezing conditions[S]. New York:The Institute of Electrical and Electronics Engineers, Inc.,2009.
|
[22] | 周仿荣. 复合绝缘子直流覆冰试验方法[D]. 重庆:重庆大学, 2009.Zhou Fangrong.DC Icing Test Method of composite Insulators [D] .Chongqing:ChongqingUniversity,2009 (in Chinese) .
|
[23] | 杨剑蓝. 盘形悬式绝缘子直流覆冰试验方法[D]. 重庆:重庆大学, 2009.Yang Jianlan.Study on Testing method of DC Artificially Iced Disk-shaped and Suspension Insulators[D].Chongqing :ChongqingUniversity,2009(in Chinese).
|
[24] | Jiang X,Chao Y,Zhang Z,et al. DC flashover performance and effect of sheds configuration on polluted and ice-covered composite insulators at low atmospheric pressure[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2011,18(1):97-105.
|