风光蓄互补发电系统容量的改进优化配置方法

, PP. 88-98

Keywords: 风光蓄互补发电系统,优化配置,分时段优化策略,供电可靠性,入网功率的波动

Full-Text   Cite this paper   Add to My Lib

Abstract:

风光互补发电系统利用风能与太阳能的互补特性,相比于单独的光伏发电或风力发电,其输出功率波动小。合理配置风电/光伏/储能的容量,既可提高系统供电可靠性,又可降低系统成本。针对风光蓄互补发电系统,提出一种改进的容量优化配置方法,考虑独立和并网两种模式,对风力发电、光伏发电和蓄电池的容量进行最优配置。该方法充分利用风光互补特性,在系统独立运行时,只需较小的蓄电池容量即可保证高供电可靠性,并可减少蓄电池的充放电次数和放电深度;在系统并网运行时,进一步提出采用分时段优化策略来配置所需蓄电池的容量,保证负荷供电需求和入网功率的波动特性满足要求。算例验证了所提改进优化方法的合理性和优越性。

References

[1]  Woyte A,Van V,Belmans R,et al. Voltage fluctuations on distribution level introduced by photovoltaic systems[J]. IEEE Trans. on Energy Conversion, 2006,21(1):202-209.
[2]  Giraud F. Analysis of a utility-interactive wind- photovoltaic hybrid system with battery storage using neural network[D]. Lowell:University of Massachusetts, 1999.
[3]  裴玮,盛鹍,孔力,等. 分布式电源对配网供电电压质量的影响与改善[J]. 中国电机工程学报, 2008,28(13):152-157. Pei Wei,Sheng Kun,Kong Li,et al.Impact and improvement of distributed generation on distribution network voltage quality[J].Proceedings of the CSEE,2008,28(13)
[4]  Kellogg W. Generation unit sizing and cost analysis for stand-alone wind,photovoltaic,and hybrid wind/PV systems[J]. IEEE Trans. on Energy Conversion, 1998,13(1):70-75.
[5]  Borowy B S,Salameh Z M. Methodology for optimally sizing the combination of a battery bank and PV array in a wind/PV hybrid system[J]. IEEE Trans. on Energy Conversion, 1996,11(2):367-375.
[6]  Shrestha G B,Goel L. A study on optimal sizing of stand-alone photovoltaic stations[J]. IEEE Trans. on Energy Conversion, 1998,13(4):373-378.
[7]  Dufo-López R,José L,Agustín B,et al. Multi-objective design of PV-wind-diesel-hydrogen-battery systems[J]. Renewable Energy, 2008,33(12):2559-2572.
[8]  Dufo-López R,José L,Agustín B,et al. Multi-objective optimization minimizing cost and life cycle emissions of stand-alone PV-wind-diesel systems with batteries storage[J]. Applied Energy, 2011,88(11):4033-4041.
[9]  Chedid R,Rahman S. Unit sizing and control of hybrid wind-solar power systems[J]. IEEE Trans. on Energy Conversion, 1997,1(12):79-85.
[10]  Chedid R,Akiki H,Rahman S. A decision support technique for the design of hybrid solar-wind power system[J]. IEEE Trans. on Energy Conversion, 1998,13(1):76-83.
[11]  Ardakani F J,Riahy G,Abedi M. Optimal sizing of a grid-connected hybrid system for north-west of Iran-case study[C]//Environment and Electrical Engineering. Prague, Czech Republic:IEEE,2010:29-32.
[12]  Menniti D,Pinnarelli A,Sorrentino N. A method to improve microgrid reliability by optimal sizing PV/wind plants and storage systems[C]//The 12th International Conference on Exhibition on Electricity Distribution. Prague, Czech Republic:IEEE,2009:8-11.
[13]  Boroyevich D,Cvetkovi? I,Dong D,et al. Future electronic power distribution system:A contemplative view-2010[C]//The 12th International Conference on Optimization of Electrical and Electronic Equipment. Brasov, Romania:IEEE,2010:1369-1380.
[14]  丁明,张颖媛,茆美琴. 包含钠硫电池储能的微网系统经济运行优化[J]. 中国电机工程学报, 2011,31(4):7-14. Ding Ming,Zhang Yingyuan,Mao Meiqin.Economic operation optimization for microgrids including Na/S battery storage[J].Proceedings of the CSEE,2011,31(4)
[15]  刘万琨. 风能与风力发电技术[M]. 北京:化学工业出版社, 2007:136-138. Liu Wankun.Wind energy and wind power generation technology[M].Beijing:ChemicalIndustry Press,2007
[16]  Manwell J F,McGowan J G. Lead acid battery storage model for hybrid energy systems[J]. Solar Energy, 1993,50(5):99-405.
[17]  Bindner H,Cronin T,Lundsager P,et al. Lifetime modelling of lead acid batteries[R]. Denmark:Ris? National Laboratory, 2005.
[18]  国家电网公司. Q/GDW392?2009风电场接入电网技术规定[S]. 北京:中国电力出版社, 2010.State Grid Corporation of China.Q/GDW392?2009 Technical rule for connecting wind farm into power grid[S].Beijing:ChinaElectric Power Press,2010(in Chinese).
[19]  国家电网公司. Q/GDW617?2011光伏电站接入电网技术规定[S]. 北京:中国电力出版社, 2011.State Grid Corporation of China.Q/GDW617?2011 Technical rule for photovoltaic power station connected to power grid[S].Beijing:ChinaElectric Power Press,2011(in Chinese).
[20]  Paatero J V,Lund P D. Effect of energy storage on variations in wind power[J]. Wind Energy, 2005,8(4):421-441.
[21]  Lilienthal P,Lambert T,Ferguson T,et al. Hybrid optimization model for electric renewables (HOMER) [EB/OL]. National Renewable Energy Lab (NREL), 2000-02-14[2010-11-.http://www.nrel/gov/HOMER.
[22]  熊信银,张步涵. 电气工程基础[M]. 武汉:华中科技大学出版社, 2005:107-117. Xiong Xinyin,Zhang Buhan.Fundamental of electrical engineering[M].Wuhan:HuazhongUniversity of Science and Technology Press,2005
[23]  Yeh T H,Wang L. A study on generator capacity for wind turbines under various tower heights and rated wind speeds using weibull distribution[J]. IEEE Trans. on Energy Conversion, 2008,23(2):592-602.
[24]  Graham V A,Hollands K G T. A method to generate synthetic hourly solar radiation globally[J]. Solar Energy, 1990,44(6):333-341.