基于起振段波形在线判别电力系统功率振荡性质

, PP. 54-60

Keywords: 电力系统,功率振荡,负阻尼振荡,强迫振荡,二次差分法

Full-Text   Cite this paper   Add to My Lib

Abstract:

电力系统功率振荡的主要分为负阻尼和强迫型振荡2种。这2种振荡的表现形式很相似,但采取的应对措施差别很大。为快速有效地判别振荡性质从而采取适当的措施抑制功率振荡,提出了一种基于起振段波形的二次差分法及相应的判别准则。针对2类功率振荡的起因及特点,通过比较该方法计算的每个周期中功率最大值(或峰峰值)的一次差分和二次差分的符号,即可在功率振荡发生后的几个或十几个周波内快速判别振荡性质。最后,采用多个实际电网的振荡实例验证了该方法的有效性及实用性。

References

[1]  汤涌.电力系统强迫功率振荡的基础理论[J].电网技术,2006,30(10):29-33.Tang Yong.Fundamental theory of forced power oscillation in power system[J].Power System Technology,2006,30(10):29-33(in Chinese).
[2]  IEEE Power System Relaying Committee Working Group.IEEE committee report “performance of generator protection during major system disturbances” [J].IEEE Transactions on Power Delivery,2004,19(4):1650-1662.
[3]  何映光,刘焘.汽轮机阀切换操作不当引发的电网功率振荡分析[J].电力自动化设备,2010(5):142-145.He Yingguang,Liu Tao.Analysis of power grid low frequency oscillation caused by improper turbine valve switchover[J].Electric Power Automation Equipment,2010(5):142-145(in Chinese).
[4]  顾丽鸿,周孝信,陶洪铸,等 局部弱联诱发互联电网强迫振荡机制分析[J].电网技术,2010,34(12):36-43.Gu Lihong,Zhou Xiaoxin,Tao Hongzhu,et al.Analysis on mechanism of inter-area forced oscillation caused by local weak interconnection in interconnected power grid[J].Power System Technology,2010,34(12):36-43(in Chinese).
[5]  王官宏,陶向宇,李文锋,等.原动机调节系统对电力系统动态稳定的影响[J].中国电机工程学报,2008,28(34):80-86.Wang Guanhong,Tao Xiangyu,Li Wenfeng,et al.Infulence of turbine governor on power system dynamic stability[J].Proceedings of the CSEE,2008,28(34):80-86(in Chinese).
[6]  李丹,苏为民,张晶,等.“9.1”内蒙古西部电网振荡的仿真研究[J].电网技术,2006,30(6):41-47.Li Dan,Su Weimin,Zhang Jing,et al.Simulation study on west Inner Mongolia Power Grid oscillations occurred on September 1st,2005[J].Power System Technology,2006,30(6):41-47(in Chinese).
[7]  张剑云,李明节,周济,等.三峡巨型电站异常功率波动仿真与试验研究[J].中国电机工程学报,2012,32(16):122-129.Zhang Jianyun,Li Mingjie,Zhou Ji,et al.Simulation and experiment research on the abnormal power fluctuation of the Three Gorges hydropower station[J].Proceedings of the CSEE,2012,32(16):122-129(in Chinese).
[8]  吴涛,周济,濮钧,等.三峡右岸电站励磁调节器检测分析[J].中国电力,2011,44(12):1-6.Wu Tao,Zhou Ji,Pu Jun,et al.Analysis and test on the automatic voltage regulator of Three Gorges right bank power station[J].Electric Power,2011,44(12):1-6(in Chinese).
[9]  朱方,汤涌,张东霞,等.我国交流互联电网动态稳定性问题的研究及解决策略[J].电网技术,2004,28(15):1-5.Zhu Fang,Tang Yong,Zhang Dongxia,et al.Study on dynamic stability problem of AC interconnected area power grid in China and their solutions[J].Power System Technology,2004,28(15):1-5(in Chinese).
[10]  余贻鑫,李鹏,大区电网互联对互联系统阻尼和动态稳定性的影响[J].中国电机工程学报,2005,25(11):6-11.Yu Yixin,Li Peng.The impact of weak internection of bulk power grids to damping and dynamic stability of power system[J].Proceedings of the CSEE,2005,25(11):6-11(in Chinese).
[11]  杨云,任刚,帅小乐.三峡右岸电站调速系统控制结构及振荡分析[J].水电站机电技术,2011,34(3):90-93.Yang Yun,Ren Gang,Shuai Xiaole.Analysis of oscillation and governor system in Three Gorges right bank power station[J].Mechanical and Electrical Technique of Hydropower Station,2011,34(3):90-93(in Chinese).
[12]  竺伟,周有庆,谭喜意,等.电网侧扰动引起共振型功率振荡的机制分析[J].中国电机工程学报,2009,29(25):37-42.Zhu Wei,Zhou Youqing,Tan Xiyi,et al.Mechanism analysis of resonance-type low-frequency oscillation caused by networks side disturbance[J].Proceedings of the CSEE,2009,29(25):37-42(in Chinese).

Full-Text