Eriksson A J.The incidence of lightning strikes to power line[J].IEEE Transaction on Power Delivery,1987,2(3):861-870.
[2]
Dellera L,Garbagnati E.Lightning stroke simulation by means of the leader progression model Part I:description of the model and evaluation of exposure of free-standing structures[J].IEEE Transaction on Power Delivery,1990,5(4):2009-2017.
[3]
Dellera L,Garbagnati E.Lightning stroke simulation by means of the leader progression model Part II:Exposure and shielding failure evaluation of overhead lines with assessment of application graphs[J].IEEE Transaction on Power Delivery,1990,5(4):2023-2029.
[4]
Rizk F A M.Modeling of transmission line exposure to direct lighting strokes[J].IEEE Transaction on Power Delivery,1990,5(4):1983-1997.
[5]
钱冠军,王晓瑜,汪雁,等.输电线路雷击仿真模型[J].中国电机工程学报,1999,19(8):39-44.Qian Guanjun,Wang Xiayu,Wang Yan,et al.Lightning simulation model of transmission line[J].Proceedings of the CSEE, 1999,19(8):39-44(in Chinese).
[6]
He Jingiang,Tu Youping,Zeng Rong,et al.Numeral analysis model for shielding failure of transmission line under lightning stroke[J].IEEE Transaction on Power Delivery,2005,20(2):815-822.
[7]
曾嵘,耿屹楠,李雨,等.高压输电线路先导发展绕击分析模型研究[J].高电压技术,2008,34(10):2041-2046.Zeng Rong,Geng Yinan,Li Yu.Lightning shielding failure model of transmission line based on leader progress model[J].High Voltage Engineering,2008, 34(10):2041-2046(in Chinese).
[8]
魏本钢,傅正财,袁海燕,等.改进先导传播模型法500 kV架空线路雷电绕击分析[J].中国电机工程学报,2008,28(25):25-29.Wei Bengang,Fu Zhengcai,Yuan Haiyan,et al.Analysis of lightning shielding failure for 500 kV overhead transmission lines based on improved leader progression model[J].Proceedings of the CSEE,2008,28(25):25-29(in Chinese).
[9]
杨庆,司马文霞,冯杰,等.云广特高压直流输电线路雷电屏蔽性能研究[J].高电压技术,2008,34(3):442-446.Yang Qing,Sima Wenxia,Feng Jie,et al.Research on the lightning shielding performance of the Yun-Guang UHVDC transmission lines[J].High Voltage Engineering,2008,34(3):442-446(in Chinese).
[10]
贺恒鑫,何俊佳,钱冠军,等.特高压交流输电线路的雷电屏蔽分析模型[J].高电压技术,2010,36(1):196-204.He Hengxin,He Junjia,Qian Guanjun,et al.Study on the lightning shielding analysis model of UHVAC overhead transmission line[J].High Voltage Engineering,2010,36(1):196-204(in Chinese).
[11]
Carrara G,Thione L.Switching surge strength of large air gaps:a physical approach[J].IEEE Transaction on Power Apparatus and Systems,1976,95(2):512-524.
[12]
Rizk F A M.Switching impulse strength of air insulation:leader inception criterion[J].IEEE Transaction on Power Delivery,1989,4(4):2187-2194.
[13]
Vahidi B,Yahyaabadi M,Tavakoli M R B,et al.Leader progression analysis model for shielding failure computation by using the charge simulation method [J].IEEE Transaction on Power Delivery,2008,23(4):2201-2206.
[14]
Gallimberti I.The mechanism of the long spark formation[J].Journal of Physics:Colloques,1979,40(C7):193-250.
[15]
Goelian N,Lalande P,Bondiou A,et al.A simplified model for the simulation of positive-spark development in long air gaps[J].Journal of Physics D:Applied Physics,1997,30(27):2441-2452.
[16]
Becerra M,Cooray V.A simplified physical model to determine the lighting upward connecting leader inception [J].IEEE Transaction on Power Delivery,2006,21(2):897-908.
[17]
谢施君,何俊佳,陈维江,等.避雷针迎面先导发展物理过程仿真研究[J].中国电机工程学报,2012,32(10):32-39.Xie Shijun,He Junjia,Chen Weijiang,et al.Simulation study on the development process of the upward leader incepted from lightning rod[J].Proceedings of the CSEE,2012,32(10):32-39(in Chinese).
[18]
Becerra M,Cooray V.Time dependent evaluation of the lightning upward connecting leader inception[J].Journal of Physics D:Applied Physics,2006,39(21):4695-4702.
[19]
Lee B Y,Park J K,Myung S H,et al.An effective modelling method to analyze the electric field around transmission lines and substations using a generalized finite line charge[J].IEEE Transaction on Power Delivery,1997,12(3):1143-1150.
[20]
Cooray V,Rakov V,Theethayi N.The lightning strike distance—revisited[J].Journal of Electrostatics,2007,65(5):296-306.
李培国.国外对特高压输电线路雷击跳闸原因的一个新观点[J].电网技术,2000,24(7):63-65.Li Peiguo. A new viewpoint about lightning trip-out of UHV transmission lines[J].Power System Technology,2000,24(7):63-65(in Chinese).
[23]
Takami J,Okabe S.Characteristics of direct lightning strokes to phase conductors of UHV transmission lines [J].IEEE Transaction on Power Delivery,2007,22(1):537-546.
[24]
Armstrong H R,Whitehead E R.Field and analytical studies of transmission line shielding[J].IEEE Transaction on Power Apparatus and System,1968,87(1):270-282.
[25]
Brown G W,Whitehead E R.Field and Analytical Studies of Transmission Lines PartⅡ[J].IEEE Trans. on Power Apparatus and System,1969,88(5):617-626.
[26]
Takami J,Okabe S.Characteristics of direct lightning strokes to phase conductors of UHV transmission lines [J].IEEE Transaction on Power Delivery,2007,22(1):537-546.
[27]
Taniguchi S,Tsuboi T,Okabe S.Observation results of lightning shielding for large-scale transmission lines [J].IEEE Transaction on Dielectrics and Electrical Insulation,2009,16(2):552-559.
[28]
陈维江,贺恒鑫,钱冠军,等.基于长间隙放电研究雷电屏蔽问题的进展[J].中国电机工程学报,2012,32(10):1-12.Chen Weijiang,HeHengxin,Qian Guanjun,et al.Review of the lightning shielding against direct lightning strokes based on laboratory long air gap discharges[J].Procee- dings of the CSEE,2012,32(10):1-12(in Chinese).
[29]
陈维江,曾嵘,贺恒鑫.长空气间隙放电研究进展[J].高电压技术,2013,39(6):1281-1295.Chen Weijiang,Zeng Rong,He Hengxin. Research progress of long air gap discharges[J]. High Voltage Engineering, 2013, 39(6): 1281-1295(in Chinese).