覆冰导线舞动响应的双参数分岔研究

DOI: 10.13334/j.0258-8013.pcsee.2014.36.028, PP. 6592-6600

Keywords: 覆冰分裂导线,舞动,双参数分岔,中心流形定理,规范形

Full-Text   Cite this paper   Add to My Lib

Abstract:

为揭示覆冰分裂导线舞动响应随双参数同时变化的规律,建立了覆冰分裂导线面内、面外和扭转耦合的非线性运动模型,并利用Galerkin积分、Routh-Hurwitz判据准则分析了覆冰导线在参数空间中的稳定域和非稳定域。以风速和风攻角为分岔参数,应用中心流形降维方法获得了原系统在平衡点附近的约化系统。采用将分岔参数视为系统状态变量的方式,把含参数的约化系统转化为不含参数的扩张系统,并结合规范形理论分段求解了导线运动方程在极坐标下的5阶Hopf分岔规范形,最后采用数值解对计算结果进行了验证。研究结果表明:所提出的理论模型能够有效预测覆冰输电线路的初始稳定性以及舞动响应在风速-初始风攻角参数空间中的变化特征。

References

[1]  Nigol O,Clarke G J,Havard D G.Torsional stability of bundle conductors[J].IEEE Transactions on Power Apparatus and Systems,1977,96(5):1666-1674.
[2]  朱宽军,尤传永,赵渊如.输电线路舞动的研究与治理[J].电力建设,2004,25(12):18-21.Zhu Kuanjun,You Chuanyong,Zhao Yuanru.Study and control on galloping of transmission lines[J].Electric Powe Construction,2004,25(12):18-21(in Chinese).
[3]  郭应龙,李国兴,尤传永.输电线路舞动[M].北京:中国电力出版社,2003:77-78.Guo Yinglong,Li Guoxing,You Chuanyong.Galloping of transmission line[M].Beijing:China Electric Power Press,2003:77-78(in Chinese).
[4]  Luongo A,Piccardo G.Non-linear galloping of sagged cables in 1 : 2 internal resonance[J].Journal of sound and vibration,1998,214(5):915-940.
[5]  Yu P,Popplewell N,Shah A H.Instability trends of inertially coupled galloping,Part I:initiation[J].Journal of Sound and Vibration,1995,183(4):663-678.
[6]  李欣业,张华彪,侯书军,等.覆冰输电线路舞动仿真分析[J].振动工程学报,2010,23(1):76-85.Li Xinye,Zhang Huabiao,Hou Shujun,et al.Theoretical and numerical analysis of galloping of iced power transmission lines[J].Journal of Vibration Engineering,2010,23(1):76-85(in Chinese).
[7]  Yan Z M,Yan Z T,Li Z L,et al.Nonlinear galloping of internally resonant iced transmission lines considering eccentricity[J].Journal of Sound and Vibration,2012(331):3599-3616.
[8]  刘延柱,陈立群.非线性振动[M].北京:高等教育出版社,2001:9-10.Liu Yanzhu,Chen Liqun.Nonlinear Vibration[M].Beijing:High Education Press,2001:9-11(in Chinese).
[9]  刘海英,张琪昌,郝淑英.覆冰四分裂导线舞动研究[J].振动工程学报,2011,24(3):235-239.Liu Haiying,Zhang Qichang,Hao Shuying.A study on galloping for iced quad-bundled conductor[M].Journal of Vibration Engineering,2011,24(3):235-239(in Chinese).
[10]  王跃方,赵光曦.三自由度偏心索风致振动稳定性分析[J].工程力学,2012,29(8):14-17.Wang Yuefang,Zhao Guangxi.Stability analysis for wind-induced vibration of 3-degree-of-freedom eccentric cables[J].Engineering Mechanics,2012,29(8):14-17(in Chinese).
[11]  Yu P.Computation of the simplest normal forms with perturbation parameters based on Lie transform and rescaling[J].Journal of Computational and Applied Mathematics,2002(144):359-373.
[12]  Yu P,Leung A Y T.The simplest normal form of Hopf bifurcation[J].Nonlinearity,2003,16(1):277-300.
[13]  Leung A Y T,Zhang Q C.Normal form computation with out central manifold reduction[J].Journal of Sound and Vibration,2012(266):261-279.
[14]  谢增,刘吉轩,刘超群,等.架空输电线路分裂导线扭转刚度计算新方法[J].西安交通大学学报,2012,45(2):100-105.Xie Zeng,Liu Jixuan,Liu Chaojun,et al.New calculation algorithm for torsional stiffness of bundle overhead transmission lines[J].Journal of Xi'an Jiaotong University,2012,45(2):100-105(in Chinese).
[15]  王洪礼,张琪昌.非线性动力学理论及应用[M].天津:天津大学出版社,2002:289-291.Wang Hongli,Zhang Qichang.The Theory and Application of Nonlinear Dynamics[M].Tianjin:Tianjin Science and Technology Press,2002:289-291(in Chinese).
[16]  Bi Q S,Yu P.Symbolic computation of normal forms for semi-simple cases[J].Journal of Computation and Applied Mathematics,1997(102):195-200.
[17]  杨风利,党会学,杨靖波,等.导线舞动时输电铁塔承载性能及破坏模式分析[J].中国电机工程学报,2013,33(22):135-141.Yang Fengli,Dang Huixue,Yang Jingbo,et al.Analysis on bearing capacities and failure modes of transmission towers with galloping conductors[J].Proceedings of the Chinese Society for Electrical Engineering,2013,33(22):135-141(in Chinese).
[18]  杨风利,杨靖波,付东杰,等.输电线路导线舞动荷载分析[J].中国电机工程学报,2011,31(16):102-107.Yang Fengli,Yang Jingbo,Fu Dongjie,et al.Analysis on the loads from galloping conductors of transmission lines[J].Proceedings of the Chinese Society for Electrical Engineering,2011,31(16):102-107(in Chinese).
[19]  丁锡广,陶文秋.减轻送电线路导线舞动灾害的措施[J].高电压技术,2004,30(2):54-55.Ding Xiguang,Tao Wenqiu.Measure for reduction of damage caused by fluttered power transmission wires[J].High Voltage Engineering,2004,30(2):54-55(in Chinese).
[20]  DenHartog J P.Transmission line vibration due to sleet[J].AIEE Transactions,1932,51(4):1074-1086.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133