1000kV交流同塔双回线路工频相参数测量计算

DOI: 10.13334/j.0258-8013.pcsee.2014.33.019, PP. 5948-5955

Keywords: 1000kV交流,同塔双回线路,相参数,测量

Full-Text   Cite this paper   Add to My Lib

Abstract:

输电线路工频相参数是线路过电压计算的基本参数,获取1000kV交流同塔双回线路的相参数对于指导工程运行是必要的。短距离输电线路相参数测量可不考虑分布参数特性也能获得较准确的结果,对于长距离线路会产生一定的误差。为获取长距离特高压线路准确的相参数,利用π型和分布参数等值电路对多导线系统进行建模分析,提出了测量各相导线首末端电压、电流列出方程组求解相间互电容的方法。基于线路分布参数特性推导出相间互阻抗计算公式,采用求解长线方程的方法获得了相、自参数。仿真结果表明,该文方法可减小误差。通过实测计算获得了皖电东送淮南至上海1000kV交流同塔双回线路淮芜Ⅰ线与Ⅱ线的相参数,为工程中过电压计算等应用提供了准确的参数。

References

[1]  孔祥鹏,薛俊茹,宋锐,等.750 kV输电线路相参数测试方法[J].青海电力,2011(30):3-6. Kong Xiangpeng,Xue Junru,Song Rui,et al.Phase parameter test method for 750kV transmission line [J].Qinghai Electric Power,2011(30):3-6(in Chinese).
[2]  张小庆,彭书涛,李小腾,等.750kV平乾同塔双回线路参数仿真计算研究[J].陕西电力,2008,36(9):14-17. Zhang Xiaoqing,Peng Shutao,Li Xiaoteng,et al.Study on parameters simulation and calculation of 750kV Ping-Qian double transmission lines on same tower [J].Shaanxi Electric Power,2008,36(9):14-17(in Chinese).
[3]  施荣,郑彬,尚勇,等.国内首例750 kV同塔双回输电线路工频参数校正[J].电网与清洁能源,2010,26(9):29-33. Shi Rong,Zheng Bin,Shang Yong,et al.Correction of frequency parameters for China’s first 750kV double- circuit transmission lines on the same tower[J].Power System and Clean Energy,2010,26(9):29-33(in Chinese).
[4]  刘遵义,卢明,吕中宾,等.特高压交流输电线路工频参数测量技术及应用[J].电网技术,2009,33(10):72-76. Liu Zunyi,Lu Ming,Lü Zhongbin,et al.Power frequency parameter measurement technology for UHV transmission lines and its application[J].Power System Technology,2009,33(10):72-76(in Chinese).
[5]  Hu Zhijian,Fang Lihua,Xie Xingsheng,et al.New method of live line measuring the impedance parameters of transmission lines[C]//Power and Energy Engineering Conference.Wuhan:IEEE,2009:1-4.
[6]  Tang Jun,Xu Jiangang,Qian Jie,et al.A precise measurement method for positive sequence parameters of EHV and UHV transmission lines and its application[C]// Power Engineering and Automation Conference (PEAM).Wuhan:IEEE,2011:208-211.
[7]  邓春,袁亦超,王征,等.长距离输电线路工频参数测量中的数据处理[J].华北电力技术,2004(2):48-50. Deng Chun,Yuan Yichao,Wang Zheng,et al.Data treating in measuring power frequency parameters at long distance transmission line[J].North China Electric Power,2004(2):48-50(in Chinese).
[8]  李澍森,陈晓燕,戚革庆,等.同塔四回输电线路参数带电测量[J].高电压技术,2006,32(7):17-20. Li Shusen,Chen Xiaoyan,Qi Geqing,et al.Discussion on live line measurement of the parameters of the transmission lines with four-circuit on a tower[J].High Voltage Engineering,2006,32(7):17-20(in Chinese).
[9]  Kurokawa S,Pissolato J,Tavares M C,et al.A new procedure to derive transmission line parameters:theoretical considerations[C]//Power Engineering Society General Meeting.San Francisco:IEEE,2005:103-111.
[10]  Asti G A,da Silva R C,Kurokawa S,et al.Identification of transmission line parameters from temporal measurements of currents and voltages in their terminals:influence of the length line[C]//Power and Energy Society General Meeting.San Diego,USA:IEEE,2012:1-7.
[11]  Sérgio Kurokawa,José Pissolato,Afonso J.Prado.Some considerations about a new procedure to derive transmission line parameters concerning three-phase lines [C]//Power Engineering Society General Meeting.Montreal,Canada:IEEE,2006:1-8.
[12]  蔡成良,程澜,范毅.异频法测量长线路工频参数的误差分析及校正[J].武汉大学学报:工学版,2012,45(1):111-116. Cai Chengliang,Cheng Nan,Fan Yi.Error analysis and correction of long line power frequency parameters measured by varying frequency method[J].Engineering Journal of Wuhan University,2012,45(1):111-116(in Chinese).
[13]  傅中,胡中慧,杨道文.500kV输电线路零序阻抗的测量及研究[J].电力系统保护与控制,2009,37(14):90-92. Fu Zhong,Hu Zhonghui,Yang Daowen.Measurement and research of the zero sequence impedance of the 500kVtransmission line[J],Power System Protection and Control,2009,37(14):90-92(in Chinese).
[14]  Kato M,Hisakado T,Takani H,et al.A Method of measuring three phase transmission line parameters for relay settings[C]//Transmission & Distribution Conference & Exposition.Seoul:IEEE,2009:1-4.
[15]  特高压交流输电标准化技术工作委员会.DL/T 1179-2012 1000kV交流架空输电线路工频参数测量导则[S].北京:中国电力出版社,2012. Technical Committee of UHV AC Transmission Standardization.DL/T 1179-2012 Guide for power frequency parameters measurement of 1000 kV AC overhead transmission lines[S].Beijing:China Electric Power Press,2012(in Chinese).
[16]  陈禾,陈维贤.超、特高压输电线路中潜供电流的电路分析和计算[J].高电压技术,2010,36(10):2368-2373. Chen He,Chen Weixian.Circuit analysis and computation of secondary current in EHV and UHV transmission lines[J].High Voltage Engineering,2010,36(10):2368-2373(in Chinese).
[17]  Grainger J J,Stevenson W D.Power system analysis [M].Singapore:McGraw-Hill Book Co.,1994:195-215.
[18]  邓春,袁亦超,王征,等.长距离双回输电线路零序互阻抗测量中的数据分析[J].华北电力技术,2004(11):11-13. Deng Chun,Yuan Yichao,Wang Zheng,et al.Data analysis in zero-sequence interimpedance measurement for long distance transmission with 2 lines in parallel [J].North China Electric Power,2004(11):11-13(in Chinese).
[19]  胡志坚,陈允平,徐玮,等.基于微分方程的互感线路参数带电测量研究与实现[J].中国电机工程学报,2005,25(2):28-33. Hu Zhijian,Chen Yunping,Xu Wei,et al.Principles and realization of live line measurement of parameters of transmission lines with mutual inductance based on differential equations[J].Proceedings of the CSEE,2005,25(2):28-33(in Chinese).
[20]  Dommel H W.电力系统电磁暂态计算理论[M].李永庄,林集明,曾昭华,译.北京:水利电力出版社,1991:41-68. Dommel H W.EMTP theory book[M].Li yongzhuang,Lin Jiming,Zeng shaohua,translated.Beijing:Water Resources and Electric Power Press,1991:41-68(in Chinese).