采用PI+重复控制的并网逆变器控制耦合机理及其抑制策略

DOI: 10.13334/j.0258-8013.pcsee.2014.30.004, PP. 5287-5295

Keywords: 并网逆变器,重复控制,PI+重复控制,控制耦合,零相位跟踪控制

Full-Text   Cite this paper   Add to My Lib

Abstract:

对于并网逆变器系统而言,为了抑制并网电流谐波,提高稳态控制精度,常采用重复控制。单一的重复控制动态性能差,PI+重复控制由于动态性能好、稳态精度高而被广泛应用。然而,比例积分(proportionalintegral,PI)调节器和重复控制器之间存在控制耦合,在动态过程中使并网电流发生畸变。该文分析了控制耦合机理,提出一种基于改进型重复控制的并网逆变器控制方法,一方面利用零相位跟踪控制(zerophaseerrortrackingcontrol,ZPETC)改善了系统的动态性能;另一方面通过对指令信号的动态延迟处理,抑制了控制耦合。最后通过仿真和实验表明理论分析的正确性和控制策略的有效性。

References

[1]  Chen Dong,Zhang Junming,Qian Zhaoming.An improved repetitive control scheme for grid-connected inverter with frequency-adaptive capability[J].IEEE Trans.Ind.Electron,2013,60(2):814-823.
[2]  Mattavelli P,Marafao F P.Repetitive-based control for selective harmonic compensation in active power filters [J].IEEE Trans.Ind.Electron,2004,51(5):1018-1024.
[3]  腾国飞,肖国春,张志波,等.采用重复控制的LCL型并网逆变器单闭环电流控制[J].中国电机工程学报,2013,33(24):13-21.
[4]  Teng Guofei,Xiao Guochun,hang Zhibo,et al.A single-loop current control method for LCL-filtered grid-connected inverters based on the repetitive controller [J].Proceedings of the CSEE,2013,33(24):13-21(in Chinese).
[5]  Castello R,Grino R,Fossa E.Odd-harmonic digital repetitive control of a single-phase current active filter[J].IEEE Trans.Power Electron,2004,19(4):1060-1068.
[6]  Escobar G,Valdez A A,Leyva-ramos J,et al.Repetitivebased controller for a UPS inverter to compensate unbalance and harmonic distortion[J].IEEE Trans.Ind.Electron,2007,54(1):504-510.
[7]  Jiang Shuai,Cao Dong,Li Yuan,et al.Low-THD,fast-transient,and cost-effectiv synchronous frame repetitive controller for three-phase UPS inverters [J].IEEE Trans.on Power Electronics,2012,27(6):2994-3005.
[8]  张凯,彭力,熊健,等.基于状态反馈与重复控制的逆变器控制技术[J].中国电机工程学报,2006,26(10):57-62.
[9]  Zhang Kai,Peng Li,Xiong Jian,et al.State-feedback- with-integral control plus repetitive control for PWM inverters[J].Proceedings of the CSEE,2006,26(10):57-62(in Chinese).
[10]  Liu Tao,Hao Xiang,Yang Xu,et al.A novel repetitive control scheme for three-phase grid-connected inverter with LCL filter[C]//Power Electronics and Motion Control Conference (IPEMC).Harbin:IEEE,2012:335-339.
[11]  王斯然,吕征宇.LCL型并网逆变器中重复控制方法研究[J].中国电机工程学报,2010,30(27):69-75.
[12]  Wang Siran,Lü Zhengyu.Research on repetitive control method applied to grid-connected inverter with LCL filter[J].Proceedings of the CSEE,2010,30(27):69-75(in Chinese).
[13]  武健,何娜,徐殿国.重复控制在并联有源滤波器中的应用[J].中国电机工程学报,2008,28(18):66-71.
[14]  Wu Jian,He Na,Xu Dianguo.Application of repetitive control technique in shunt active power filter [J].Proceedings of the CSEE,2008,28(18):66-71(in Chinese).
[15]  王成智,邹旭东,许赟,等.采用改进重复控制的大功率电力电子负载[J].中国电机工程学报,2009,29(12):1-9.
[16]  Selvaraj J,Rahim N.Multilevel inverter for grid- connected PV system employing digital PI controller [J].IEEE Trans.Ind.Electron,2009,56(1):149-158.
[17]  Yang Shuitao,Qin Lei, Fang Zhengpeng,et al.A robust control scheme for grid-connected voltage-source inverters[J].IEEE Trans.Ind.Electron,2011,58(1):202-212.
[18]  Miguel C,Jaume M,José M,et al.Control design guidelines for single-phase grid-connected photovoltaic inverters with damped resonant harmonic compensators [J].IEEE Trans. on Industrial Electronics,2009,56(11):4492-4501.
[19]  Shen Guoqiao,Zhu Xuancai,Zhang Jun,et al.A new feedback method for PR current control of LCL-filter-based grid-connected inverter[J].IEEE Trans.Ind.Electron,2010,57(6):2033-2041.
[20]  Hornik T,Zhong Qingchang.A current-control strategy for voltage-source inverters in microgrids based on H∞and repetitive control[J].IEEE Trans.Power Electron,2011,26(3):943-952.
[21]  Wang Chengzhi,Zou Xudong,Xu Yun,et al.Improved repetitive control scheme for power electronic load [J].Proceedings of the CSEE,2009,29(12):1-9(in Chinese).
[22]  Yoshiya K,Kiyoshi O,Yuta N,et al.Zero phase error tracking control system with multi harmonics disturbance suppression loop[C]//The 11th IEEE International Workshop on Advanced Motion Control.Nagaoka,Japan:IEEE,2010:377-382.
[23]  Mohamed Y A R I,Rahman A M,Seethapathy R.Robust line-voltage sensorless control and synchronization of LCL-filtered distributed generation inverters for high power quality grid connection[J].IEEE Trans.on Power Electronics,2012,27(1):87-98.
[24]  吴云压,谢少军,阚加容,等.逆变器侧电流反馈的LCL并网逆变器电网电压前馈控制策略[J].中国电机工程学报,2013,33(6):54-60.
[25]  Wu Yunya,Xie Shaojun,KanJiarong,et al.A full grid voltage feed-forward control strategy with inverter-side current feedback for LCL grid-connected inverters [J].Proceedings of the CSEE,2013,33(6):54-60(in Chinese).
[26]  Hoff,ann N,Fuchs F W,Dannehl J.Models and effects of different updating and sampling concepts to the control of grid-connected PWM converters-a study based on discrete time domain analysis[C]//Power Electronics and Applications (EPE 2011).Birmingham:IEEE,2011:1-10.
[27]  Aguilera R P,Lezana P, Quevedo E.Finite-control-set model predictive control with improved steady-state performance[J].IEEE Trans.on Industrial Electronics,2013,9(2):658-667.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133