某核电站蒸汽发生器杂质隐藏返回研究

, PP. 199-203

Keywords: 核电站,杂质离子,隐藏返回,水化学,腐蚀

Full-Text   Cite this paper   Add to My Lib

Abstract:

压水堆核电站运行过程中,蒸汽发生器二次侧流动受限区域的表面污垢及缝隙中的有害杂质离子(如Cl-,SO42-,Ca2+,Mg2+,Al3+等)因水的蒸发会出现局部浓缩.通过监测机组停运期间的水化学可以推断机组正常运行期间蒸汽发生器二次侧的杂质浓缩情况.本文分析和评估了某核电站降功率、降温期间蒸汽发生器的3次杂质隐藏返回试验数据.结果表明,隐藏区内的Al3+浓度逐年增加;根据隐藏返回数据得到的高温pH值(pHT)在正常的耐腐蚀pH值范围内;建议机组降温的时间应该进一步延长,以便杂质离子尤其是阴离子完全返回进入大空间溶液并通过排污水系统排出.

References

[1]  SawochkaS G, Choi S S, Fruzzetti K. Relationship between bulk and local chemistries (hideout return) in Molar ratio control and non Molar ratio control[A]. Proceedings in Improving the UnderStanding and Control of Corrosion on the Secondary Side of Steam Generators[C]. Airlie, VA, USA.
[2]  Chemistry SW, Committee G R. PWR Secondary Water Chemistry Guidelines - Revision 3 (EPRI-TR-102134) [M].California: EPRI, 1993
[3]  IAEA.Water Chemistry of WWER Nuclear Power Plants[M].Austria, IAEA, 2007
[4]  Lurie S, Eaker R, Bucci G, et al. PWR Molar Ratio Control Application Guidelines Volume 1: Summary[M]. California: EPRI, 1995
[5]  Stutzmann, Nordmann A F, OllarP. Measurement of hideout return. Proceedings in Control of Corrosion on the Secondary Side of Steam Generator[C]. Houston: NACE, 1996
[6]  Rogers P M, McNeil M. Sodium Chloride Hideout in a Simulated Steam Generator Tube and Tube Support Plate Crevice (Report TR-110803)[M]. CA: EPRI, 1998
[7]  Odar S, Nordmann F. PWR and VVER secondary system water chemistry[A]. Advanced Nuclear Technology International Europe [C]. ABANT International, 2010: 5
[8]  Gui C. Integrity assessment of steam generator tubing in QNPC 310 MWe nuclear power unit (Chinese)[A]. China Nuclear Power Operation Technology Corporation[C]. LTD, 2008: 17
[9]  Lu Y C. Electrochemical aspect of defining the safe potential/pH zone for corrosion prevention of Alloy 800 SG tubing[A]. AECL 4th CNS International Steam Generator Conference[C]. Canada, 2002
[10]  Lu Y C. Evaluation of SCC susceptibility of alloy 800 under CANDU SG secondary side condition[A].AECL 5th CNS International Steam Generator Gonference[C]. Canada, 2006