20G钢氢腐蚀的超声背散检测
, PP. 179-183
Keywords: 氢腐蚀,超声波,背散法,检测
Abstract:
选用20G低碳钢,经450℃和500℃,18MPa氢气中分别暴露240,480和720小时,使材料发生不同程度氢腐蚀,用背散法对氢蚀进行了超声波检测结果表明,背散法对氢蚀程度非常敏感,用杂草波平均高度与原始波高之比做为信噪比,能很好地反映氢蚀程度,论证了用背散法检测氢蚀程度的可能性.
References
[1] | 1.ShewmonP.G.,Metall.Trans.A,1976;7A:279.2.WatanabeT.,HasagwaT.,ASTMSTP908,Philadelphia,Pennsylvania,1986;153.3.BirringA.S.,BartlettM.L.andKawanoK.,CorrosionEngineering,1989;3:45.4.SeniorP.,SzilardJ.,Ultrasonic,1984;Jan:42.5.OdetteG.R.,VagaraliS.,Metall.Trans.A,1982;13A:299.6.中国无损检测学会编,超声波探伤,机械工业出版社,北京.1987.7O'connellR.,J.BudianskyB.J.,GeophysicalResearch,1977;82(36):57198.长谷川,溶接学会志(日),1987;56:393.9.ChenL.,SheY.B.,EnW.Q.,ACTA,Metall.Sinica,1978;14:255.
|