Chen Jie, Gong Chunying, Chen Jiawei, et al. A novel full-size power converter for wind energy conversion system[J]. Transactions of China Electrotechnical Society, 2012, 27(11): 160-168.
[3]
Peng F Z, Li Yun Wei, Tolbert L M. Control and protection of power electronics interfaced distributed generation systems in a customer-driven microgrid[C]. IEEE PESC’09, Calgray, Canada, 2009.
Liu Bo, Yang Xu, Kong Fanlin, et al. Control strategy study for three phase photovoltaic grid-connected inverters[J]. Transactions of China Electrotechnical Society, 2012, 27(8): 64-70.
Guo Ke, Zeng Yi, Liu Qiang, et al. Application of LCL-filter in photovoltaic grid-connected system with active power filter function[J]. Power System Protection and Control, 2013, 41(3): 73-79.
Wang Yubin, Chen Jianliang. High performance LCL-based utility-interactive inverter design and parallel applications[J]. Power System Protection and Control, 2010, 38(20): 110-114, 120.
[10]
M Tavakoli Bina, E Pashajavid. An efficient procedure to design passive LCL-filters for active power filters[J]. Electric Power Systems Research, 2009, 79(4): 606-614.
Guo Xiaoqiang, Wu Weiyang, Gu Herong, et al. Modelling and stability analysis of direct output current control for LCL interfaced grid-connected inverters[J]. Transactions of China Electrotechnical Society, 2010, 25(3): 102-109.
Huang Zhixiong, Xu Baoyou, Shen Lingfei, et al. New current double closed loop control strategy of LCL grid-connected inverter[J]. Power System Protection and Control, 2012, 40(17): 1-5.
Bai Zhihong, Ruan Xinbo, Xu Lin. Control strategies for the grid-connected inverter with LCL filter[J]. Transactions of China Electrotechnical Society, 2011, 26(S1): 118-124.
Liu Fei, Zha Xiaoming, Duan Shanxu. Design and research on parameter of LCL filter in three-phase grid-connected inverter[J]. Transactions of China Electrotechnical Society, 2010, 25(3): 110-116.
[19]
Liserre M, Blaabjerg F, Hansen S. Design and control of an LCL-filter based active rectifier [J]. IEEE Transactions On Industry Applications, 2005, 41(2) : 1281-1291.
[20]
Lang Yongqiang, Xu Dianguo, Hadianamrei SR, et al. A novel design method of LCL type utility interface for three-phase voltage source rectifier[C]. IEEE Power Electronics Specialists Conference, Recife, Brazil, 2006.
Yan Shijie, Wang Xu, Chen Hongzhi. Decoupling control of three-phase four-leg inverter in micro- turbine power generation[J]. Transactions of China Electrotechnical Society, 2012, 27(1): 69-73.
Yao Zhilei, Xiao Lan, Chen Liangliang. An improved decoupling control method for three-phase grid- connected inverters with SVPWM[J]. Automation of Electric Power Systems, 2012, 36(20): 99-103.
Yang Yong, Zhao Fangping, Ruan Yi, et al. Model current predictive control for three-phase grid- connected inverters[J]. Transactions of China Electrotechnical Society, 2011, 26(6): 153-159.
Xu Zhiying, Xu Aiguo, Xie Shaojun. Dual-loop grid current control technique for grid-connected inverter using an LCL filter[J]. Proceedings of the CSEE, 2009, 29(27): 36-41.
Liu Fei, Duan Shanxu, Zha Xiaoming. Design of two loop controller in grid-connected inverter with LCL filter[J]. Proceedings of the CSEE, 2009, 29(S1): 234-240.
Wang Yaoqiang, Wu Fengjiang, Sun Li, et al. Control strategy for grid-connected inverter with an LCL output filter[J]. Proceedings of the CSEE, 2011, 31(12): 34-39.