Rong Mingzhe,Yang Fei,Wu Yi,et al.New developments in switching arc research in DC circuit breaker[J].Transactions of China Electrotechnical Society,2014,29(1):1-8.
Guan Ruiliang,Liu Hongwu.Application study on low voltage circuit breakers used for active electric network[J].Power System Protection and Control,2015,43(3):127-130.
Li Xintao,Lin Xin,Xu Jianyuan,et al.Breakdown characteristics of SF6 in uniform electric field using FEM-FCT[J].High Voltage Engineering,2014,40(10):3046-3053.
Wu Yi,Rong Mingzhe,Wang Xiaohua,et al.Dynamic analysis of low-voltage air arc plasma during contact opening process[J].Transactions of China Electrotechnical Society,2008,23(5):12-17.
[13]
Uhm H S,Byeon Y S,Song K B,et al.Analytical investigation of electrical breakdown properties in a nitrogen-SF6 mixture gas[J].Physics of Plasmas,2010,17(11):113510-113510-8.
[14]
Bini R,Mahdizadeh N,Seeger M,et al.Measurements and simulation of the dielectric recovery in a SF6 circuit breaker[C].17th International Conference on Gas Discharges and Their Applications,Cardiff,2008:113-116.
[15]
Wu Yi,Rong Mingzhe,Sun Zhiqiang,et al.Numerical analysis of arc plasma behavior during contact opening process in low-voltage switching device[J].Journal of Physics D:Applied Physics,2007,40(3):795-802.
Rong Mingzhe,Yang Qian,Fan Chunduo.Simulation of the process of arc energy-effect in H.V.auto-expansion SF6 circuit breaker[J].Power of the CSEE,2004,24(2):92-97.
Liu Weidong,Wu Junyong,Huang Yulong,et al.Pressure measurement in SF6 circuit breaker’s nozzle in heavy current interruption[J].Power of the CSEE,2010,30(7):131-136.
Lin Xin,Zhong Jianying.A new thought for computation of gas flow field in the arc-quenching chamber of self-blasting circuit breaker[J].Proceeding of the CSEE,2003,23(10):164-168.
Lin Xin,Liu Kebin.Puffer characteristic calculation in different initial gas pressure and operating force of self-extinguishing SF6 circuit breaker[J].Power System Technology,2007,40(10):22-25.
[24]
马强,荣命哲,Murphy Anthony B,等.考虑器壁侵蚀影响的低压断路器电弧运动特性仿真及实验[J].电工技术学报,2009,24(12):74-81.
[25]
Ma Qiang,Rong Mingzhe,Murphy Anthony B,et al.Simulation and experiment on air arc characteristics in low-voltage circuit breaker considering wall ablation[J].Transactions of China Electrotechnical Society,2009,24(12):74-81.
Rong Mingzhe,Liu Dingxin,Li Mei,et al.Research status and new progress on the numerical simulation of non-equilibrium plasmas[J].Transactions of China Electrotechnical Society,2014,29(6):271-282.
[28]
Isaac L T,Jones G R,Humphries J E,et al.Monitoring particle concentrations produced by arcing in SF6 circuit breakers using a chromatic modulation probe[J].IEEE Proceedings Science Measurement and Technology,1999,146(4):199-204.
[29]
Schade E,Regaller K.Dielectric recovery of an axially blown SF6 arc after current zero:Part I-experimental investigations[J].IEEE Transactions on Plasma Science,1982,10(3):141-153.
[30]
Regaller K,Egli W, Brand K P.Dielectric recovery of an axially blown SF6 arc after current zero:Part Ⅱ-theoretical investigations[J].IEEE Transactions on Plasma Science,1982,10(3):154-162.
Wang Feiming,Lin Xin,Xu Jianyuan.Extinction characteristics of non-equilibrium plasma arc in high-voltage SF6 circuit breaker[J].High Voltage Engineering,2014,40(10):3073-3084.
Lin Xin,Li Xintao,Wang Feiming,et al.Dielectric recovery characteristics of SF6 circuit breaker considering contact burning loss[J].High Voltage Engineering,2014,40(10):3125-3134.
[35]
魏俊梅.800kV SF6高压断路器的研究与开发[D].沈阳:沈阳工业大学,2008.
[36]
马强,荣命哲,Murphy Anthony B,等.考虑电机烧蚀影响的低压断路器电弧运动特性仿真及实验[J].中国电机工程学报,2009,29(3):115-120.
[37]
Ma Qiang,Rong Mingzhe,Murphy Anthony B,et al.Simulation and experiment research on air arc movement characteristics in low-voltage circuit breaker considering electrodes erosion[J].Power of the CSEE,2009,29(3):115-120.
[38]
Vahid A,Ahmad G,Kaveh N.Three-dimensional simulation of plasma deformation during contact opening in a circuit breaker,including the analysis of kink instability and sausage instability[J].Plasma Science and Technology,2012,14(11):996-1001.
Zhu Kai,Li Xingwen,Zhao Hu,et al.Experimental study on characteristics of post-arc current of high voltage gas circuit breaker[J].Power of the CSEE,2014,34(21):3512-3517.
Fang Chunen,Liang Minghua,Pang Li,et al.Research on intelligent control unit for circuit breakers controlled fault interruption[J].Power System Protection and Control,2012,40(23):138-144.
Du Shuping,Wu Junfang,Zhao Min,et al.Analysis of SF6 circuit breaker with spring operating mechanism fitting for reclosure[J].Power System Protection and Control,2009,37(19):122-126.
[45]
Anderson John D,Jr.Computational fluid dynamics:the basics with applications[M].New York:R.R.Donnelley & Sons Company,1995.