Stewart J R,Wilson D D.High phase order transmission-a feasibility analysis:part II-over voltages and insulation requirements[J].IEEE Transactions on Power Apparatus and Systems,1997,35(6):2308-2317.
Liu Jiajun.Influence of series compensation capacitor on zero-sequence reactance-type distance protection in parallel double-circuit lines[J].Transactions of China Electrotechnical Society,2011,26(7):264-270.
Li Bin.Circulating unbalanced current and its influence of double-circuit UHV transmission lines[J].Transactions of China Electrotechnical Society,2012,27(4):202-208.
Chen Fufeng,Qian Guoming.Research on fault phase selector of protective relay for double circuit lines based on crossing-line fault identifying[J].Automation of Electric Power Systems,2008,32(6):66-70.
Yu Bo,Yang Qixun,Li Ying,et al.Research on fault phase selector of protective relay for double circuit lines on the same tower[J].Proceedings of the CSEE,2003,23(4):38-42.
Zhang Hai,Huang Shaofeng.A fault phase selection scheme of currents with assistant voltages for common-tower double-circuit transmission lines using one-terminal electrical quantities[J].Proceedings of the CSEE,2013,33(7):139-148.
Li Zhenxing.A study of wide-area protection algorithm based on integrated impedance comparison[J].Transactions of China Electrotechnical Society,2012,27(8):179-186.
Li Wei,Bi Tianshu,Xu Zhenyu,et al.Analysis of phase selector action and improving scheme for two-phase-to-ground fault[J].Power System Protection and Control,2012,40(3):67-72.
Tian Shu,Liu Fangfang,Ren Xiaoming.Research on transient-based faulty phase selection for double-circuit lines on the same tower[J].Power System Protection and Control,2015,43(1):50-54.
Zeng Genghui,Huang Minghui,Liu Zhiyao,et al.Analysis on mis-operations of zero-sequence protective relay in double circuit lines on the same tower[J].Automation of Electric Power System,2006,30(20):103-107.
Zhang Qibing,Tai Nengling,Yuan Cheng,et al.Phase-mode transformation of four-parallel lines on the same tower[J].Proceedings of the CSEE,2009,29(34):57-62.
Liu Ling,Fan Chunju.Fault calculation for joint four transmission lines of different voltage grades on the same tower based on six-sequence-component method[J].Power System Protection and Control,2010,38(9):6-11.
Hu Zhijian,Jiang Meiling.Setting of zero sequence current compensation coefficient for four-circuit transmission lines in different voltage classes on same tower[J].Power System Technology,2012,35(7):60-66.
Zhou Chunxia,Yu Yue,Zhao Han,et al.Influence of zero-sequence current compensation coefficient setting on earth-fault distance protection for double circuit uhvac transmission lines on the same tower[J].Power System Technology,2012,36(12):106-111.
Ma Jing,Shi Yuxin,Ma Wei,et al.Distributed parameter based one-end fault location for inter-line fault and earth fault in double-circuit transmission lines on same tower[J].Power System Technology,2014,36(9):2525-2531.