李建基. SF 6 在高压断路器和GIS不同放电下的分解物[J]. 华通技术, 1992(3): 58-64, 46.
[2]
Chu F Y. SF 6 decomposition in gas insulated equipment[J]. IEEE Transactions on Electric Insulation, 1986, 21(5): 693-725.
[3]
Tominaga S, Kuwahara H, Hirooka K, et a1. SF 6 gas analysis technique and its application for evaluation of internal conditions in SF 6 gas equipment [J]. IEEE Transactions on Power Apparatus and Systems, 1981, 100(9): 4196-4206.
[4]
Li Jianji. The decompositions of SF 6 in high voltage circuit breaker and GIS under different discharge[J]. Hua Tong Technology, 1992(3): 58-64, 46.
[5]
汪金星, 杨韧, 郑小川. SF 6 开关设备带电测试新技术在陕西电网的应用[J]. 陕西电力, 2008, 36(11): 15-17.
[6]
Wang Jinxing, Yang Ren, Zhen Xiaochuan. Applica- tion of novel live test methods for SF 6 switch equipment to Shaanxi power grid[J]. Shaanxi Electric Power, 2008, 36(11): 15-17.
Liu Yong, Yin Hua, Yao Qiang, et al. The application of gas analysis technology to fault location and fault diagnosis of GIS[J]. High Voltage Apparatus, 2009, 45(3): 132-134.
Yan Xianglian, Wang Chengyu, Ji Yansong, et al. Application of decomposition products detection of SF 6 in switchgears[J]. Power System Technology, 2010, 34(9): 160-165.
Ji Yansong, Wang Chengyu, Yang Ren, et al. Measuring technique of SF 6 decomposition products and its application to fault diagnosis of GIS[J]. High Voltage Apparatus, 2011, 47(2): 110-103.
Yan Xianglian, Wang Chengyu, Yang Ren, et al. Fault diagnosis of high voltage switchgears by decomposition products of SF 6 [J]. Power System Technology, 2011, 35(12): 120-123.
[15]
Beyer C, Jenett H, Klockow D. Influence of reactive SFx gases on electrode surfaces after electrical discharges under SF 6 atmosphere[J]. IEEE Transactions on Dielec- trics and Electrical Insulation, 2000, 7(2): 234-240.
[16]
Belarbi, Pradayrol A C, Casanovas J, et a1. Influence of discharge production conditions, as pressure, current intensity and voltage type, oil SF 6 dissociation under point-plane corona discharges[J]. Journal of Applied Physics, 1995, 77(4): 1398-1406.
[17]
Belmadani, Casanovas B J, Casanovas A M. SF 6 decomposition under power arcs[J]. IEEE Transactions on Chemical Aspects B, 1991, 26(6): 1177-1182.
Liu Youwei, Wu Liyuan, Gong Yanpeng. Investigation on SF 6 decomposition products in GIS and affecting factors[J]. Power System Technology, 2009, 33(5): 58-61.
Zhang Xiaoxing, Yao Yao, Tang Ju, et al. Actuamity and perspective of proximate analysis of SF 6 decomposed products under partial discharge[J]. High Voltage Engineering, 2008, 34(4): 664-747.
[22]
袁亮. 高压电器中SF 6 气体分解物的检测与研究[D]. 长春: 长春理工大学, 2009.
[23]
Suehiro J, Zhou G B, Hara M. Detection of partial discharge in SF 6 gas using a carbon nanotube based gas sensor[J]. Sensors and Actuators, 2005, 105(2): 164-169.
[24]
Derdouri A, Casanovas J. 3 Spark decomposition mixtures of SF 6 /H 2 O[J]. IEEE Transactions on Electrical Insulation, 1989, 24(6): 1147-1157.
[25]
IEC 60480—2004 guidelines for the checking and treatment of sulfur hexafluoride(SF 6 ) taken from electrica1 equipment and specification for its re-use[S]. 2004.