全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

基于LCL滤波器的并网逆变器的控制策略

, PP. 118-124

Keywords: LCL滤波器,并网逆变器,前馈控制

Full-Text   Cite this paper   Add to My Lib

Abstract:

采用LCL滤波器的并网逆变系统是一个三阶系统,该系统在谐振频率处有较大的幅值增益尖峰,稳定裕度小,使得对并网电流误差调节器的设计复杂化。针对该问题,本文采用网侧(或逆变器侧)电流反馈和一种状态量前馈解耦相结合,提出了一种能使系统从三阶降为一阶的控制策略。采用该方法,控制系统不仅可以获得较大的稳定裕度,而且由于系统阶数降为一阶,谐振频率处的幅值增益尖峰消失了,从而电流误差调节器的设计得以大大简化。此外,为了消除电网电压畸变以及当地负载突变等扰动对逆变器并网电流的影响,本文也给出了相应的控制策略,改善了系统输出电流的质量。仿真结果验证了这种控制方法的正确性和有效性。

References

[1]  Kroposki B, Pink C, Deblasio R, et al. Benefits of power electronic interfaces for distributed energy systems [C]. Proceedings of the IEEE Power Engineering Society General Meeting, 2006: 1-8.
[2]  赵清林, 郭小强, 邬伟扬. 单相逆变器并网控制技术研究[J]. 中国电机工程学报, 2007, 27(16): 60-64.
[3]  Bierhoff M H, Fuchs W F. Active damping for three-phase PWM rectifiers with high-order line-side filters [J]. IEEE Transaction. on Industrial Electronics, 2009, 56(2): 371-379.
[4]  Wu Eric Lehn, Peter W. Digital current control of a voltage source converter with active damping of LCL resonance[J]. IEEE Transaction on Power Electronics, 2006, 21(5): 1364-1373.
[5]  Shen Guoqiao, Xu Dehong, Cao Luping, et al. An improved control strategy for grid-connected voltage source inverters with an LCL filter[J]. IEEE Transactions on Power Electronics, 2008, 23(4): 1899-1906.
[6]  Liserre M, Teodorescu R, Blaabjerg F. Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values[J]. IEEE Transactions on Power Electronics, 2006, 21(1): 263-272.
[7]  Zue O A, Chandra A. Simulation and stability analysis of a 100kW grid connected LCL photovoltaic inverter for industry[C]. Proceedings of the IEEE Power Engineering Society General Meeting, 2006: 1-6.
[8]  Sun Wei, Wu Xiaojie, Dai Peng, et al. An over view of damping methods for three-phase PWM rectifier[C]. Proceedings of the IEEE International Conference on Industrial Technology, 2008: 1-5.
[9]  Liserre M, Blaabjerg F, Hansen S. Design and control of an LCL-filter-based three-phase active rectifier[J]. IEEE Transactions on Industry Applications, 2005, 41(5): 1281-1291.
[10]  Twining E, Holmes D G. Grid current regulation of a three-phase voltage source inverter with an LCL input filter[J]. IEEE Transactions on Power Electronics, 2003, 18(3): 888-895.
[11]  Loh P C, Newman M J, Zmood D N, et al. A comparative analysis of multiloop voltage regulation strategies for single and three-phase UPS systems [J]. IEEE Transactions on Power Electronics, 2003, 18(5): 1176-1185.
[12]  Loh P C, Halmes D G. Analysis of multiloop control strategies for LC/CL/LCL-filtered voltage-source and current-source inverters[J]. IEEE Transactions on Industry Applications, 2005, 41(2): 644-654.

Full-Text