高压脉冲造成储能电容器老化的直流局部放电测试技术

, PP. 172-178

Keywords: 储能电容器,绝缘,老化,直流,局部放电

Full-Text   Cite this paper   Add to My Lib

Abstract:

高压储能电容器是脉冲功率系统的关键器件之一,应具有高的可靠性,但个别电容器在工作期间会发生过早击穿,给系统带来极大的隐患。如能准确评估其绝缘状态,对整个系统的工作稳定性有很大的提高。本文提出直流局部放电是检测试样绝缘老化的适宜方法,并研究了老化后的电容器绝缘在直流局部放电试验中的测试电压、测试方向和测试时间;按照上述标准划分了过渡区、平稳区,按照一定测量方向和顺序,得到了有效的直流局部放电数据;最后对击穿后的试样解剖并分析,认为直流局部放电参量变化可有效反映其绝缘状态。

References

[1]  Wisken H G, Podeyn F, Weise H G. High energy density capacitors for etc gun applications[J]. IEEE Transactions on Magnetics, 2001, 37(1): 332-335.
[2]  Slenes K M, Winsor P, Scholz T, et al. Pulse power capability of high energy density capacitors based on a new dielectric material[J]. IEEE Transactions on Magnetics, 2001, 37(1): 324-327.
[3]  Stone G C. Partial discharge diagnostics and electrical equipment insulation condition assessment[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2005, 12(5): 891-904.
[4]  郭俊, 吴广宁, 张血琴, 等. 局部放电检测技术的现状和发展[J]. 电工技术学报, 2005, 20(02): 29-35.
[5]  Peter Morshuis, Gerard Hoogenraad. Partial discharge diagnositics for DC equipment[C]. Conference Record of the 1996 IEEE International Symposium on Electrical Insulation, Montreal, Quebec, Canada, 1996: 407-410.
[6]  Peter Morshuis, Marc Jeroense, Jens Beyer. Partial discharge part XXIV: the analysis of PD in HVDC equipment[J]. IEEE Electrical Insulation Magazine, 1997, 13(2): 6-16.
[7]  Peter Morshuis, Jens Beyer. Quality assessment of HVDC components by PD analysis[C]. 1997 IEEE Annual Report Conference on Electrical Insulation and Dielectric Phenomena, Cancun, Quintana Roo, Mexico, 2002: 736-739.
[8]  Hoogenraad G, Beyer J. Digital HVDC partial dis- charge testing[C]. Conference Record of the 2000 IEEE International Symposium on Electrical Insula- tion, Anaheim, California, America, 2000: 448-451.
[9]  于钦学, 邱昌容, 谢恒堃. 油纸绝缘直流局部放电的研究[J]. 变压器, 1998(2): 17-20.
[10]  Erling Ildstad, Terje Haave. Conduction and partial discharge activity in HVDC cable insulation of lapped polypropylene films[C]. Proceedings of the 7th IEEE International Conference on Solid Dielectrics, Eindhoven, Dutch, 2001: 137-140.
[11]  Qu Yanning, Wu Guangning, Zhang Xueqin, et al. Detecting instrument for dc partial discharge within storage capacitor[C]. Conference Record of the 2006 IEEE International Symposium on Electrical Insulation, 2006: 328-331.
[12]  Lesaint Q, Tobazeon R. Study of the generation by sharp electrodes of a gaseous phase in dielectric liquids subjected to high AC or step voltages[J]. IEEE Transactions on Electrical Insulation, 1985, 20(2): 269-273.
[13]  Macdougall F W, Ennis J B, Cooper R A, et al. High energy density pulsed power capacitors[C]. 14th IEEE International on Pulsed Power Conference, PPC-2003, 2003: 513-517.
[14]  Ennis J, Huiyang Xiao, Macdougall F, et al. High energy density capacitor characterization[C]. Power Modulator Symposium 2004 and High-Voltage Workshop, Conference Record of the Twenty-Sixth International, 2004: 68-71.
[15]  Bartnikas R. Partial discharges: their mechanism, detection and measurement[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2002, 9(5): 763- 808.
[16]  Zhang Xueqin, Wu Guangning. Quality evaluation of high voltage storage capacitor through DC partial discharge measurement[C]. Proceedings of the 2004 IEEE International Conference on Solid Dielectrics, 2004: 755-758.
[17]  Hoogenraad G, Morshuis P, Petrarca C. Classification of partial discharges for DC equipment [C]. IEEE Annual Report Conference on Electrical Insulation and Dielectric Phenomena, Millbrae, America, 1996: 110-112.
[18]  张血琴, 吴广宁, 曲衍宁, 等. 高压储能电容器直流局部放电检测仪的研制[J]. 西南交通大学学报, 2006, 41(6): 743-747.