Peng F Z, Lai J S, J McKeever W, et al. A multilevel voltage-source inverter with separate DC sources for static var generation[J]. IEEE Transactions on Industry Applications, 1996, 32(5): 1130-1138.
[2]
Liang Y, Nwankpa C O. A new type of STATCOM based on cascading voltage-source inverters with phase-shifted unipolar SPWM[J]. IEEE Transactions on Industry Applications, 1999, 35(5): 1118-1123.
[3]
Lee C K, Leung J S K, Hui S Y R, et al. Circuit-level comparison of STATCOM technologies[J]. IEEE Transactions on Power Electronics, 2003, 18(4): 1084-1092.
[4]
Han C, Yang Z, Chen B, et al. Evaluation of cascade multileve converter based STATCOM for arc furnace flicker mitigation[J]. IEEE Transactions on Industry Applications, 2007, 43(2): 378-385.
Peng F Z, McKeever J W, Adams D J. A power line conditioner using cascade multilevel inverters for distribution systems[J]. IEEE Transactions on Industry Applications, 1998, 34(6): 1293-298.
[7]
Song Q, Liu W, Yuan Z. Multilevel optimal modulation and dynamic control strategies for STATCOMs using cascaded multilevel inverters[J]. IEEE Transactions on Power Delivery, 2007, 22(3): 1937-1946.
Leon J I, Vazquez S, Watson A J, et al. Feed-forward space vector modulation for single-phase multilevel cascaded converters with any DC voltage ratio[J]. IEEE Transactions on Industrial Electronics, 2009, 56(2): 315-325.
[10]
Vazquez S, Leon J I, Franquelo L G, et al. DC-voltage-ratio control strategy for multilevel cascaded converters fed with a single DC source[J]. IEEE Transactions on Industrial Electronics, 2009, 56 (7): 2513-2521.
[11]
Barrena J A, Marroyo L, Vidal M Á R, et al. Individual voltage balancing strategy for PWM cascaded H-bridge converter-based STATCOM[J]. IEEE Transactions on Industrial Electronics, 2008, 55(1): 21-29.
Y Xiangzhen, S Jianhui, D Yan, et al. Research on master-slave control strategy of capacitor voltage for cascade STATCOM[C]. Proceedings of the Deregulation and Restructuring and Power Technologies, 2008: 1620-1624.
[14]
Akagi H, Inoue S, Yoshii T. Control and performance of a transformerless cascade PWM STATCOM with star configuration[J]. IEEE Transactions on Industry Applications, 2007, 43(4): 1041-1049.
[15]
Liu Y, Huang A Q, Song W, et al. Small-signal model-based control strategy for balancing individual DC capacitor voltages in cascade multilevel inverter-based STATCOM[J]. IEEE Transactions on Industrial Electronics, 2009, 56(6): 2259-2269.
[16]
Song Q, Liu W. Control of a cascade STATCOM with star configuration under unbalanced conditions[J]. IEEE Transactions on Power Electronics, 2009, 24(1): 45-58.
[17]
Hatano N, Ise T. Control scheme of cascaded H-bridge STATCOM using zero-sequence voltage and negative- sequence current[J]. IEEE Transactions on Power Delivery, 2010, 25(2): 543-550.
[18]
Loh P C, Holmes D G, Lipo T A. Implementation and control of distributed PWM cascaded multilevel inverters with minimal harmonic distortion and common-mode voltage[J]. IEEE Transactions on Power Electronics, 2005, 20(1): 90-99.
[19]
Park Y M, Yoo J Y, Lee S B. Practical Implementation of PWM synchronization and phase-shift method for cascaded H-Bridge multilevel inverters based on a standard serial communication protocol[J]. IEEE Transactions on Industry Applications, 2008, 44(2): 634-643.
[20]
单庆晓. 级联型逆变器关键技术研究[D]. 长沙:国防科学技术大学, 2003.
[21]
黄海泉. 单相级联逆变器的分布式控制研究[M]. 南京:南京航空航天大学, 2008.
[22]
Zhang K, Kang Y, Xiong J, et al. Direct repetitive control of SPWM inverter for UPS purpose[J]. IEEE Transactions on Power Electronics, 2003, 18(3): 784-792.