Clade J J, Gary C H. Predetermination of corona losses under rain: experimental interpreting and checking of a method to calculate corona losses[J]. IEEE Transactions on Power Apparatus and Systems, 1970, 89(5): 853-860.
Zhao Yuming, Ma Minhua, Chu Jinwei, et al. Measurement methods for DC conductor corona onset voltage in the corona cage[J]. High Voltage Engineering, 2008, 34(8): 1567-1572.
[8]
Maruvada P S. Corona performance of high-voltage transmission lines[M]. London, UK: Research Studies Press Ltd, 2000.
Bian Xingming, Hui Jianfeng, Huang Haikun, et al. Research on negative DC corona characteristics related to air pressure and humidity[J]. Proceedings of the CSEE, 2010, 30(4): 118-124.
Liu Youwei, Li Jihong, Li Bin. Influence of air density and humidity on the corona performance of conductor[J]. Power System Technology, 1990, 14(4): 46-50.
Liu Yunpeng, You Shaohua, Wan Qifa, et al. Research on UHV AC single circuit test line corona losses under rain[J]. Proceedings of the CSEE, 2010, 30(19): 114-119.
[21]
Wang Qingliang, Zhang Lu, Li Zhou, et al. Influence of corona characteristics of water drops on smooth conductor under negative DC voltage[J]. High Voltage Apparatus, 2011, 47(8): 9-17.
Fan Jianbin, Li Zhongxin, Gu Chen, et al. Calculation method for DC onset corona voltage[J]. Transactions of China Electrotechnical Society, 2008, 23(10): 100-105.
Meng Xiaobo, Bian Xingming, Chen Fenglin, et al. Analysis on negative DC corona inception voltage of stranded conductors[J]. High Voltage Engineering, 2011, 34(9): 1797-1801.
[27]
Ali Z, Ahamad G, Vahraz Z. A new method for calculation of corona inception voltage in stranded conductors of overhead transmission lines[C]. First International Power and Energy Conference, 2006: 571-574.
[28]
林锐. 直流正极性下导线电晕放电特性及影响因素的研究[D]. 重庆: 重庆大学, 2009.
[29]
EI-Bahy M M, Abouelsaad M. Onset voltage of negative corona on stranded conductors[J]. Journal of Physics D: Applied Physics, 2007, 40(10): 3094-3101.
[30]
Abdel-Salam M. Calculating the effect of high temperatures on the onset voltages of negative discharges[J]. Journal of Applied Physics, 1976, 9(12): 149-154.
[31]
Abdel-Salam M. Calculation of corona onset voltage for duct-type precipitators[J]. IEEE Transactions on Industry Applications, 1993, 29(2): 274-280.
[32]
Li Wei, Zhang Bo, He Jinliang, et al. Corona losses calculation of UHV/EHV AC transmission lines[J]. Proceedings of the CSEE, 2009, 29(19): 118-124.
[33]
Lü F C, You S H, Liu Y P, et al. AC conductors’ corona-loss calculation and analysis[J]. IEEE Transactions on Power Delivery, 2012, 27(2): 877-885.
[34]
宫林. 低气压下导线表面状况对电晕放电起始特性影响的研究[D]. 重庆: 重庆大学, 2008.
[35]
Xie Shuyong, Liu Cheng, Li Zheng. The method for measuring initial corona of super high voltage transmission line[J]. High Voltage Apparatus, 1989, 25(6): 39-41.