CF3I-CO2混合气体在针板电极下局部放电绝缘特性实验研究

, PP. 36-42

Keywords: CFI-CO,局部放电起始电压,温室效应,混合比,协同效应

Full-Text   Cite this paper   Add to My Lib

Abstract:

由于SF6气体严重的温室效应影响,减少或杜绝SF6气体的使用已经达成共识,有关SF6替代气体的研究围绕一种电负性气体和缓冲气体的混合气体展开。本文在针板电极下通过工频实验同时测量了CF3I-CO2的局部放电起始电压和击穿电压,讨论了混合比、压强对混合气体局部放电性能的影响,并与SF6-CO2混合气体的局部放电起始电压进行比较。实验结果表明一个大气压下,纯CF3I的击穿电压是SF6的1.2倍;CF3I-CO2的局部放电起始电压是SF6-CO2的0.9~1.1倍,同时,CF3I气体与CO2气体具有很好的协同效应,协同效应值为0.53;CF3I-CO2(30%-70%)混合气体的局部放电能力是纯SF6的0.74倍。因此,从局部放电性能的角度来看,CF3I-CO2(30%-70%)混合气体有可能替代SF6气体用在气体绝缘设备中。

References

[1]  Christophorou L G, Van Brunt R J. SF6/N2 mixtures basic and HV insulation properties[J]. IEEE Transanctions on Dielectrics and Electrical Insulation, 1995, 2(5): 952-1003.
[2]  Christophorou L G, Olthoff J K, Van Brunt R J, et al. Sulfur Hexafluoride and the electric power industry[J]. IEEE Electrical Insulation Magazine, 1997, 13(5): 20-24.
[3]  Koch H, Hillers T, et al. Second generation gas-insulated line[J]. Power Engineering Journal, 2002, 16(3): 111-116.
[4]  Yamamoto O, Takuma T, Hamada S, et al. Applying a gas mixtures containing c-C4F8 as an insulation medium[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2001, 8(6): 1075-1081.
[5]  Wu Biantao, Xiao Dengming, Liu Zhangsheng, et al. Analysis of insulation characteristics of c-C4F8 and N2 gas mixtures by Monte Carlo method[J]. Journal of Physics D: Applied Physics, 2006, 39(19): 4204-4207.
[6]  Zhang Liuchun, Xiao Dengming, Zhang Dong, et al. SST experimental analysis on the feasibility of c-C4F8/CF4 substituting SF6 as insulation medium[J]. Transactions of China Electrotechnical Society, 2008, 23(6): 14-18.
[7]  Okubo H, Yamada T, Hatta K, et al. Partial discharge and breakdown mechanisms in ultra-dilute SF6 and PFC gases mixed with N2 gas[J]. Journal of Physics D: Applied Physics, 2002, 35(21): 2760-2765.
[8]  Katagiri H, Kasuya H, Mizoguchi H, et al. Investigation of the performance of CF3I gas as a possible substitute for SF6[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2008, 15(5): 1424-1429.
[9]  Katagiri H, Kasuya H, Mizoguchi H, et al. BTF interruption capability of CF3I-CO2 mixture[C]. The 17th International Conference on Gas Discharges and Their Applications, Cardiff, 2008: 105-108.
[10]  Nguyen Ngoc M, Denat A, Bonifaci N, et al. Electrical breakdown of CF3I and CF3I-N2 gas mixtures[C]. 2009 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, Virginia Beach, 2009: 557-560.
[11]  Yokomizu Y, Ochiai R, Matsumura T, et al. Electrical and thermal conductivities of high-temperature CO2-CF3I mixture and transient conductance of residual arc during its extinction process[J]. Journal of Physics D: Applied Physics, 2009, 42(21): 5204-5217.
[12]  张晓星, 谌阳, 唐俊忠, 等. 检测GIS局部放电的小型准TEM喇叭天线[J]. 高电压技术, 2011, 37(8): 1975-1981.
[13]  Watson R. Common themes for ecologists in global issues[J]. Journal of Applied Ecology, 1999, 36(1): 1-10.
[14]  Malik N H, Qureshi A H, et al. A review of electrical breakdown in mixtures of SF6 and other gases[J]. IEEE Transactions on Electrical Insulation, 1979, EI-14(1): 1-13.
[15]  Hikita M, Ohtsuka S, Okabe S, et al. Insulation characteristics of gas mixtures including perfluorocarbon gas[J]. IEEE Transanctions on Dielectrics and Electrical Insulation, 2008, 15(4): 1015-1022.
[16]  周辉, 邱毓昌, 等. N2-SF6混合气体的绝缘特性[J]. 高压电器, 2003 , 39(5): 13-15.
[17]  Zhou Hui, Qiu Yuchang, et al. Insulation characteristics of N2-SF6 gas mixtures[J]. High Voltage Apparatus, 2003, 39(5): 13-15.
[18]  Yamada T, Ishida T, Hayakawa N, et al. Partial discharge and breakdown mechanisms in ultra- dilute SF6/N2 gas mixtures[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2001, 8(1): 137-142.
[19]  Zhang Liuchun, Xiao Dengming, Zhang Dong, et al. Applying c-C4F8/CO2 substituting SF6 as insulation medium at low E/N (<400Td)[C]. 16th International Conference on Gas Discharges and Their Applications, Xi’an, 2006: 749-752.
[20]  张刘春, 肖登明, 张栋, 等. c-C4F8/CF4替代SF6可行性的SST实验分析[J]. 电工技术学报, 2008, 23(6): 14-18.
[21]  Taki M, Maekawa D, Odaka H, et al. Interruption capability of CF3I gas as a substitution candidate for SF6 gas[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2007, 14(2): 341-346.
[22]  J de Urquijo, A M Juárez, E Basurto, et al. Electron impact ionization and attachment drift velocities and longitudinal diffusion in CF3I and CF3I-N2 mixtures[J]. Journal of Physics D: Applied Physics, 2007, 40(7): 2205-2209.
[23]  Zhang Xiaoxing, Chen Yang, Tang Junzhong, et al. Minitype quasi-TEM horn antenna for partial discharge detection in GIS[J]. High Voltage Engineering, 2011, 37(8): 1975-1981.
[24]  Judd M D, Farish O, Hampton B F, et al. The excitation of UHF signals by partial discharges in GIS[J]. IEEE Transactions on Dielectrics and Electrical Insulation. 1996, 3(2): 213-228.
[25]  Takuma T, Watanabe T, Kita K, et al. Breakdown characteristics of compressed-gas mixtures in nearly uniform fields[J]. Proceedings of the Institution of Electrical Engineers, 1972, 119(7): 927-928.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133