单级式光伏并网逆变器的非线性控制

, PP. 204-211

Keywords: 单级式光伏并网逆变器,非线性控制器,反馈线性化,自抗扰控制,最大功率跟踪

Full-Text   Cite this paper   Add to My Lib

Abstract:

针对光伏电池输出特性的非线性,本文提出一种单级式光伏并网逆变器的非线性综合控制策略。该策略采用状态反馈线性化的非线性控制方法,实现逆变器有功电流和无功电流的精确解耦控制;采用自抗扰控制设计逆变器直流母线电压环,补偿系统建模参数误差对反馈线性化的不利影响,提升并网逆变器的控制鲁棒性;在有功电流与无功电流精确解耦控制、电压环大范围稳定运行的基础上,采用基于有功电流和电压环输入误差信号的变步长扰动最大功率跟踪方法,可避免光伏阵列最大功率点的误判。所提非线性综合控制策略通过状态反馈电流环、自抗扰电压环和变步长扰动最大功率跟踪算法的有机结合,有效提升了逆变器的整机控制性能。仿真和实验表明了该控制策略的正确性和可行性。

References

[1]  张兴, 曹仁贤. 太阳能光伏并网发电及其逆变控制[M]. 北京: 机械工业出版社, 2011.
[2]  张承慧, 叶颖, 陈阿莲, 等. 基于输出电流控制的光伏并网逆变电源[J]. 电工技术学报, 2007, 22(8): 41-45.
[3]  Zhang Chenghui, Ye Ying, Chen Alian, et al. Research on grid-connected photovoltaic inverter based on output current control[J]. Transactions of China Electrotechnical Society, 2007, 22(8): 41-45.
[4]  Casadei D, Grandi G, Rossi C. Single-phase single-stage photovoltaic generation system based on a ripple correlation control maximum power point tracking[J]. IEEE Transactions on Energy Conversion, 2006, 21(2): 562-568.
[5]  Wu Libo, Zhao Zhengming, Liu Jianzheng. A single-stage three-phase grid-connected photovoltaic system with modified MPPT method and reactive power compensation[J]. IEEE Transactions on Energy Conversion, 2007, 22(4): 881-886.
[6]  Kadri R, Gaubert J, Champenois G. An improved maximum power point tracking for photovoltaic grid-connected inverter based on voltage-oriented control[J]. IEEE Transactions on Industrial Electronics, 2011, 58(1): 66-75.
[7]  Daizhan Cheng, Xiaoming Hu, Tielong Shen. Analysis and design of nonlinear control systems[M]. Beijing: Science Press&Springer, 2010.
[8]  Changliang Xia, Qiang Geng, Xin Gu, et al. Input-output feedback linearization and speed control of a surface permanent-magnet synchronous wind generator with the Boost-chopper Converter[J]. IEEE Transactions on Industry Electronics, 2012, 59(9): 3489-3500.
[9]  Dong Eok Kim, Dong Choon Lee. Feedback linearization control of three-phase ups inverter systems[J]. IEEE Transactions on Industrial Electronics, 2012, 57(3): 963-968.
[10]  Shengyi Liu, Dougal R. Dynamic multiphysics model for solar array[J]. IEEE Transactions on Energy Conversion, 2002, 17(2): 285-294.
[11]  Jingqing Han. From PID to active disturbance rejection control[J]. IEEE Transactions on Industrial Electronics, 2009, 56(3): 900-906.
[12]  Esram T, Chapman P. Comparison of photovoltaic array maximum power point tracking techniques[J]. IEEE Transactions on Energy Conversion, 2007, 22(2): 439-449.