Bagheri M,Naderi M S,Blackburn T,et al. On-line transformer winding deformation diagnosis: a profound insight to methods[C]. 26th International Power System Conference,2011: 1-14.
Pham D A K,Pham T M T,Safari M H,et al. FRA-based transformer parameters at low frequencies [C]. IEEE International Conference on High Voltage Engineering and Application (ICHVE),2012: 476-479.
[7]
Florkowski M,Furgał J. Modelling of winding failures identification using the frequency response analysis (FRA) method[J]. Electric Power Systems Research,2009,79(7): 1069-1075.
[8]
Satish L,Sahoo S K. Locating faults in a transformer winding: An experimental study[J]. Electric Power Systems Research,2009,79(1): 89-97.
[9]
Oguz Soysal A. A method for wide frequency range modeling of power transformers and rotating machines [J]. IEEE Transactions on Power Delivery,1993,8(4): 1802-1810.
[10]
Joshi P M,Kulkarni S V. A novel approach for on-line deformation diagnostics of transformer windings[C]. IEEE Power and Energy Society General Meeting,2010: 1-6.
[11]
Wang M,Vandermaar A J,Srivastava K. Improved detection of power transformer winding movement by extending the FRA high frequency range[J]. IEEE Transactions on Power Delivery,2005,20(3): 1930- 1938.
[12]
Setayeshmehr A,Akbari A,Borsi H,et al. New sensors for on-line monitoring of power transformer bushings [C]. Nordic Insulation Symposium,2005: 151-154.
[13]
Liu Mengna,Peng Fadong,Ke Chunjun,et al. Diagnosis analysis on transformer winding deformation failure[J]. Guangdong Electric Power,2012,25(11): 108-111.
[14]
Wang Jue,Li Yanming,Zhang Chengliang. The comparisonal study on LVI and FRA method of detecting winding deformation faults in transformers [J]. High Voltage Engineering,1997,23(01): 13-15.
Xu Dake,Ji Shengchang,Li Yanming. A theorectical research on on-line monitoring of winding deformation of power transformer[J]. High Voltage Engineering,2000,26(03): 16-18.
Liu Xingping,Chen Minyou. A novel method on on- line monitoring of winding deformation of transformers [J]. Power System Protection and Control,2013,41(12): 20-26.
[19]
Secue J,Mombello E. Sweep frequency response analysis(SFRA) for the assessment of winding displace- ments and deformation in power transformers[J]. Electric Power Systems Research,2008,78(6): 1119- 1128.
[20]
Joshi P M,Kulkarni S. Use of a deformation coefficient for transformer winding diagnostics[J]. International Journal of Emerging Electric Power Systems,2008,9(3): 1-15.
[21]
De Rybel T,Singh A,Vandermaar J A,et al. Apparatus for online power transformer winding monitoring using bushing tap injection[J]. IEEE Transactions on Power Delivery,2009,24(3): 996- 1003.
[22]
Setayeshmehr A,Borsi H,Gockenbach E,et al. On-line monitoring of transformer via transfer function [C]. Electrical Insulation Conference,2009: 278-282.
[23]
Akbari A,Borsi H,Gockenbach E,et al. Experiences with a non-invasive capacitive sensor for on-line partial discharge detection in power transformers[J]. Diagnostik Elektrischer Betriebsmittel: Vorträge der ETG-Fachtagung am 09. und 10. März in Köln,2004,97: 301-304.
[24]
Joshi P,Kulkarni S. A diagnostic method for deter- mining deformations in a transformer winding: India,2009069145[P]. 2009-06-04.