贺博, 万军, 金海云, 等. 复合绝缘子的老化特征分析[J]. 高压电器, 2009, 45(1): 21-24. He Bo, Wan Jun, Jin Haiyun, et al. Aging character analysis of composite insulators[J]. High Voltage Apparatus, 2009, 45(1): 21-24.
[2]
Liu H P, Cash G, Birtwhistle D, et al. Characterization of a severely degraded silicon elastomer HV insulator- an aid to development of lifetime assessment techniques [J]. IEEE Trans. Dielectr. Electr. Insul., 2005, 12(3): 478-486.
梁曦东, 王成胜, 范炬. 合成绝缘子芯棒脆断性能及试验方法的研究[J]. 电网技术, 2003, 27(1): 34-37. Liang Xidong, Wang Chengsheng, Fan Ju. Research on brittle fracture of frp rods and the test method[J]. Power System Technology, 2003, 27(1): 34-37.
[5]
郭浩. 我国复合绝缘子的应用及运行中的若干问题[J]. 电力设备, 2006, 7(4): 43-45. Guo Hao. Some problems in application and operation of composite insulator in China[J]. Electrical Equip- ment, 2006, 7(4): 43-45.
[6]
刘洋, 刘贞瑶, 周志成, 等. 500kV进口合成绝缘子芯棒脆断原因分析及对策[J]. 江苏电机工程, 2011, 30(2): 25-27. Liu Yang, Liu Zhenyao, Zhou Zhicheng, et al. Analysis and countermeasures of core brittle fracture of imported composite insulator on 500 kV transmis- sion line[J]. Jiangsu Electrical Engineering, 2011, 30(2): 25-27.
[7]
郭清滔, 廖福旺, 黄海鲲. 一起复合绝缘子芯棒脆断原因分析及对策[J]. 电瓷避雷器, 2010, 233: 19-21. Guo Qingtao, Liao Fuwang, Huang Haikun. Analysis on cause of core brittle fracture of composite insulators and its preventive measures[J]. Insulators and Surge Arresters, 2010, 233: 19-21.
[8]
卢明, 马晓久, 阎东, 等. 复合绝缘子芯棒脆断原因分析[J]. 电瓷避雷器, 2007, 218: 1-4. Lu Ming, Ma Xiaojiu, Yan Dong, et al. Analysis on causes of brittle fracture of composite insulator cores[J]. Insulators and Surge Arresters, 2010, 233: 19-21.
[9]
贾志东, 张威, 方苏, 等. 湿污环境中的复合绝缘子异物闪络[J]. 高电压技术, 2010, 36(8): 1893-1899. Jia Zhidong, Zhang Wei, Fang Su, et al. Foreign body caused flashover on composite insulator in wet and contaminated condition[J]. High Voltage Engineering, 2010, 36(8): 1893-1899.
[10]
肖猛, 文曹, 司马文霞, 等. 硅橡胶表面的分离水珠放电与不明原因闪络[J]. 重庆大学学报(自然科学版), 2006, 29: 42-46. Xiao Meng, Wen Cao, Sima Wenxia, et al. Discharges between discrete water drops on the silicone rubber surface and reason unknown flashover[J]. Journal of Chongqing University(Natural Science Edition), 2006, 29: 42-46.
[11]
龚坚刚, 包建强. 浙江合成绝缘子“不明原因”工频闪络的试验分析[J]. 高电压技术, 2001, 27(5): 70-71. Gong Jiangang, Bao Jianqiang. The test and analysis of power frequency flashover of composite insulator on transmission line[J]. High Voltage Engineering, 2001, 27(5): 70-71.
[12]
Liang X D, Wang S W, Fan J, et al. Development of composite insulators in China[J]. IEEE Transacions on Dielectric and Electrical Insulatin, 1999, 6(5): 586-594.
[13]
Rowland S M, Xiong Y, Robertson J, et al. Aging of silicone rubber compositer insulators on 400kV transmission lines[J]. IEEE Transacions on Dielectric and Electrical Insulatin, 2007, 14(1): 130-136.
陆泓昶, 黎亮, 李李. 三峡荆州—益阳Ⅱ回500kV输电线路杆塔规划研究[J]. 电力建设, 2007, 28(12): 47-50. Lu Hongchang, Li Liang, Li Li. Research on tower planning of Jingzhou-Yiyang 500kV double circuit line[J]. Electric Power Construction, 2007, 28(12): 47-50.
[17]
胡兆意. 500千伏输电线路造价简析[J]. 电力技术, 1984(3): 1-5. Hu Zhaoyi. Project cost of 500kV transmission lines[J]. Electrical Power, 1984(3): 1-5.
[18]
戴罕奇, 梅红伟, 王黎明, 等. 复合绝缘子弱憎水性状态描述方法I——静态接触角法的适用性[J]. 电工技术学报, 2013, 28(8): 34-47. Dai Hanqi, Mei Hongwei, Wang Liming et al. Descrip- tion method I—for unobvious hydrophobic state of composite insulators usability of contact angle method [J]. Transactions of China Electrotechnical Society, 2013, 28(8): 34-47.
[19]
戴罕奇, 梅红伟, 王黎明, 等. 复合绝缘子弱憎水性状态描述方法II——喷水分级法的不确定性[J]. 电工技术学报, 2015, 30(3): 240-249. Dai Hanqi, Mei Hong-wei, Wang Li-ming et al. Description method for unobvious hydrophobic state of composite insulators II—uncertainty of hydro- phobic degree by spray grading method[J]. Transactions of China Electrotechnical Society, 2015, 30(3): 240- 249.
Zhu Dingyi, Zhang Yuanchao, Dai Pinqiang, et al. Novel characterization of wetting properties and the calculation of liquid-solid interface tension(II)[J]. Science Technology and Engineering, 2007, 7(13): 3063-3069.