全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

基于触头动态接触压力的触头弹跳分析

, PP. 138-144

Keywords: 触头接触压力,触桥,触头弹跳,压电薄膜,危险振动

Full-Text   Cite this paper   Add to My Lib

Abstract:

根据弹性波原理,以CJ20-25型交流接触器为试验品,采用以压电薄膜为敏感元件制成的触头接触压力传感器,分别测得一相主触头触桥上两个触头的动态接触压力信号,用以研究该相主触头的触头弹跳情况;利用高速摄像机技术分析了触头运动过程中的摆动和振动情况;应用小波工具箱对该触头接触压力信号进行了降噪处理;研究了触头弹跳与触头断通信号的关系以及触头弹跳与合闸相角的关系。由分析结果可见,触头动态接触压力信号可揭示触头弹跳和断通信号的变化原因,合闸相角为60°时,各项指标综合最差。

References

[1]  熊军,何俊佳,臧春艳.基于正交实验的航天继电器触头弹跳的多因素分析[J].电工技术学报,2009,24(2):60-66.
[2]  Xiong Jun,He Junjia,Zang Chunyan.Multifactor analysis on contact bounce of aerospace relay based on orthogonal experiments[J].Transactions of China Electrotechnical Society,2009,24(2):60-66.
[3]  纽春萍,陈德桂,李兴文.交流接触器触头弹跳的仿真及影响因素[J].电工技术学报,2007,22(10):85-90.
[4]  Niu Chunping,Chen Degui,Li Xingwen.Simulation of contact bounce of AC contactor and study of its influence factors[J].Transactions of China Electrotechnical Society,2007,22(10):85-90.
[5]  刘教民,孙祎,王震洲,等.交流接触器开关电弧的图像采集与处理[J].电工技术学报,2010,25(1):64-69.
[6]  Liu Jiaomin,Sun Yi,Wang Zhenzhou et al.Switching arc’s image gathering and processing in AC contactors[J].Transactions of China Electrotechnical Society,2010,25(1):64-69.
[7]  鲍光海,张培铭.智能交流接触器零电流分断技术[J].电工技术学报,2012,27(5):199-204.
[8]  Bao Guanghai,Zhang Peiming.Technology of zero-current breaking of intelligent AC contactor[J].Transactions of China Electrotechnical Society,2012,27(5):199-204.
[9]  罗宗杰.基于正态分布随机因素的变压器和应涌流概率仿真研究[J].电力系统保护与控制,2011,39(4):90-93.
[10]  Luo Zongjie.Simulation study on transformer and sympathetic inrush probability based on normal distribution random factors[J].Power System Protection and Control,2011,39(4):90-93.
[11]  Tarczynski W,Hejman T,Smugal D.Computer-controlled testing system for investigating the dynamic characteristics of contactors with AC electromagnet drives[J].Measurement,2003,33(4):313-323.
[12]  周亮,吴桂初,谢文彬.基于激光位移器的交流接触器动态测试与分析[J].温州大学学报,2013,34(3):32-37.
[13]  Zhou Liang,Wu Guichu,Xie Wenbin.The dynamic testing and analysis on contactors based on laser probing displacement[J].Journal of Wenzhou University (Natural Sciences),2013,34(3):32-37.
[14]  陈德为,张培铭.基于高速摄像机的智能交流接触器动态测试与分析技术[J].仪器仪表学报,2010,31(4):878-884.
[15]  Chen Dewei,Zhang Peiming.High-speed camera-based intelligent AC contactor dynamic testing and analysis techniques[J].Chinese Journal of Scientific Instrument,2010,31(4):878-884.
[16]  陈德为,张培铭.采用高速摄像机的智能交流接触器控制及其测试装置的研制[J].电工电能新技术,2009,28(3):58-61.
[17]  Chen Dewei,Zhang Peiming.Control and testing device for intelligent AC contactor using high-speed camera[J].Advanced Technology of Electrical Engineering and Energy,2009,28(3):58-61.
[18]  鲍光海,张培铭.基于高速摄像机的电磁电器动态特性测试及其图像处理的研究[J].南昌大学学报(工科版),2009,31(4):376-380.
[19]  Bao Guanghai,Zhang Peiming.The research of dynamic characteristics testing device for electromagnetic apparatus based on high speed camera and image processing[J].Journal of Nanchang University(Engineering & Technology),2009,31(4):376-380.
[20]  王亚光.应力条件下弹性波在材料中的传播规律[D].秦皇岛:燕山大学,2012.
[21]  Wang Yichun,Chen Yuwen.Application of piezoelectric PVDF film to the measurement of impulsive forces generated by cavitation bubble collapse near a solid boundary[J].Experimental Thermal and Fluid Science,2007,32(2):403-414.
[22]  Shirinov A V,Schomburg W K.Pressure sensor from a PVDF film[J].Sensors and Actuators,2008,142(1):48-55.
[23]  李俊峰,郑新芳,苏秀苹,等.应用PVDF压电薄膜进行触头接触压力动态测试研究[J].河北工业大学学报,2014,43(4):7-10.
[24]  Li Junfeng,Zheng Xinfang,Su Xiuping,et al.Prevue on dynamic measurement of contact pressure using piezoelectric PVDF film[J].Journal of Hebei University of Technology,2014,43(4):7-10.
[25]  周伟.基于MATLAB的小波分析应用[M].西安:西安电子科技大学出版社,2010.
[26]  张明,李开成,胡益胜.基于Bayes估计的双小波维纳滤波电能质量信号去噪算法[J].电力系统保护与控制,2011,39(4):52-57.
[27]  Zhang Ming,Li Kaicheng,Hu Yisheng.Power quality signals denoising via double-wavelet Wiener filtering based on Bayes estimation[J].Power System Protection and Control,2011,39(4):52-57.
[28]  房国志,杨超,赵洪.基于FFT和小波包变换的电力系统谐波检测方法[J].电力系统保护与控制,2012,40(5):75-79.
[29]  Fang Guozhi,Yang Chao,Zhao Hong.Detection of harmonic in power system based on FFT and wavelet packet[J].Power System Protection and Control,2012,40(5):75-79.