Zhang Wenliang,Zhou Xiaoxin,Guo Jianbo,et al.Feasibility of ±1 000 kV ultra HVDC in the power grid of China[J].Proceedings of the CSEE,2007,27(28):1-5.
Li Xingyuan,Zhao Rui,Liu Tianqi,et al.Research of conventional high voltage direct current transmission system stability analysis and control[J].Transactions of China Electrotechnical Society,2013,28(10):288-300.
Wu Ping,Zhang Jian,Tu Jingzhe,et al.Stability characteristics and coordinated control strategy of grid-integrated UHVDC transmission line from Xiluodu to Zhexi[J].Power System Technology,2014,38(7):1873-1878.
[11]
Li Fengqi,She Zhengqiu,Lou Dianqiang,et al.Fault analysis of DC voltage dividers in Xiangjiaba-Shanghai ±800 kV UHVDC project[J].High Voltage Engineering,2012,38(12):3244-3248.
Wang Feng,Yi Chang,Zhang Guangdong,et al.Design of anti-wind and anti-corona 24-bundle conductors for UHVDC voltage withstand test[J].Transactions of China Electrotechnical Society,2014,29(11):247-254.
Wang Liming,Wang Chuang,Yuan Tian,et al.Mechanical characteristics of porcelain long rod suspension insulators for tension strings on HVDC transmission lines[J].High Voltage Engineering,2012,38(3):655-662.
Li Jing,Peng Zongren,Liao Jintao,et al.Voltage-sharing characteristics of II-shaped tension ceramic insulator string with jumpers in UHVDC substation[J].Power System Technology,2012,36(4):16-21.
[21]
Chandrasekar S,Kalaivanan C,Cavallina A,et al.Investigations on leakage current and phase angle characteristics of porcelain and polymeric insulator under contaminated conditions[J].IEEE Transactions on Dielectrics Electrical Insulation,2009,16(2):574-583.
Zhang Fuzeng,Liao Yifan,Luo Ling,et al.Accelerated electrolytic erosion test of metal cap of DC porcelain insulator for UHVDC transmission line[J].Power System Technology,2014,38(2):311-315.
Zeng Chen,Li Yong,Wang Pin.Analysis and recommendations of insulator gossans corrosion of heavy ice zone in ±800 kV Fufeng line[J].Hubei Power,2012,36(5):66-67.
[26]
Crabtree I M,Mackey K J,Kito K,et al.Studies on electrolytic corrosion of hardware of DC line insulators[J].IEEE Transactions on Power Apparatus and Systems,1985,104(3):645-654.
[27]
Taniguchi T,Watanabe M,Watanabe Y.Electrolytic corrosion of metal hardware of HVDC line and station insulators[J].IEEE Transactions on Power Delivery,1991,6(3):1224-1233.
Gao Liying,Sun Tao,Zhao Jiangtao,et al.Experimental research on anti-electrolytic corrosion characteristics of insulator cap for DC porcelain cap and pin insulator by zinc collar[J].Power System Technology,2013,37(12):3381-3385.
[32]
Bardeen A W,Sheadel J M.Corrosion as it affects insulator and conductor hardware[C].IEEE Transactions on Power Apparatus and Systems,New York,1956:491-501.
Wang Xuan,Cao Xiaolong,Xu Man.Study and test of electrochemical corrosion for HVDC support insulator[J].High Voltage Engineering,2006,32(3):31-33.
[35]
金毅,蔡炜.直流绝缘子耐腐蚀性能分析[J].电瓷避雷器,2004,8(5):17-21.
[36]
Jin Yi,Cai Wei.Evaluation on corrosion proof performance of DC insulator[J].Insulators and Surge Arresters,2004,8(5):17-21.
[37]
Galanov V I,Koshcheev L A,Dimitrev V L,et al.Research on the corrosion property of long bar porcelain insulators under HVDC[R].St Petersburg,Russia:DC Transmission Technology Research Center of Russia,1999:31-38.