全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

三相逆变器开关管故障诊断方法研究进展

, PP. 135-144

Keywords: 三相逆变器,功率器件,故障诊断,开路故障

Full-Text   Cite this paper   Add to My Lib

Abstract:

逆变器的安全运行得到了研究者的广泛重视。对现有的逆变器开关管开路故障诊断方法进行了归类和总结,从检测变量的角度将其分为两大类基于电流量的诊断方法和基于电压量的诊断方法。文章首先以开环V/F感应电机控制系统和永磁同步电机矢量控制系统为例,对逆变器的开路故障效应进行了仿真,分析了故障诊断方法所依据的电压和电流模式。在此基础上,介绍了各故障诊断方法的原理,并从适用性、算法复杂性、诊断时间和可靠性等角度,对这些方法进行了对比,指出了逆变器开关管故障研究的难点和今后的研究方向。

References

[1]  Rothenhagen K, Fuchs F W. Performance of diagnosis methods for IGBT open circuit faults in three phase voltage source inverters for AC variable speed dirves[C]. Proceedings of the 11th European Conference on Power Electronics and Applications, Dresden, Germany, 2005: 7-16.
[2]  Fuchs F W. Some diagnosis methods for voltage source inverters in variable speed drives with induction machines—a survey[C]. Proceedings of the IEEE Industrial Electronics Society Annual Conference, Roanoke, Virginia, USA, 2003: 1378- 1385.
[3]  Welchko B A, Lipo T A, Jahns T M, et al. Fault tolerant three-phase AC motor drive topologies: a comparison of features, cost, and limitations[J]. IEEE Transactions on Power Electronics, 2004, 19(4): 1108-1116.
[4]  张兰红, 胡育文, 黄文新. 三相变频驱动系统中的逆变器的故障诊断与容错技术[J]. 电工技术学报, 2004, 19(12): 1-9.
[5]  Mendes A M S, Cardoso A J M. Voltage source inverter fault diagnosis in variable speed AC drives by the average current Park’s vector approach[C]. Proceedings of the IEEE International Electric Machines and Drives Conference, Madison, USA, 1999: 704-706.
[6]  Abramik S, Sleszynski W, Nieznanski J, et al. A diagnostic method for on-line fault detection and localization in VSI-fed AC drives[C]. Proceedings of the 10th European Conference on Power Electronics and Applications, Toulouse, France, CD-ROM.
[7]  Rothenhagen K, Fuchs F W. Performance of diagnosis methods for IGBT open circuit faults in voltage source active rectifiers[C]. Proceedings of the 35th Annual IEEE Power Electronics Specialists Conference, Aachen, Germany, 2004: 4348-4354.
[8]  Park J H, Kim D H, Kim S S, et al. C-ANFIS based fault diagnosis for voltage-fed PWM motor drive systems[C]. Proceedings of the IEEE Annual Meeting of the Fuzzy Information, Alberta, Canada, 2004: 379-383.
[9]  Zidani F, Diallo D, Benbouzid M E H, et al. A fuzzy-based approach for the diagnosis of fault modes in a voltage-fed PWM inverter induction motor drive[J]. IEEE Transactions on Industrial Electronics, 2008, 55(2): 586-593.
[10]  Khanniche M S, Mamat M R. Wavelet-fuzzy-based algorithm for condition monitoring of voltage source inverter[J]. Electronics Letters, 2004, 40(4): 267-268.
[11]  杨忠林, 吴正国, 李辉. 基于直流侧电流检测的逆变器开路故障诊断方法[J]. 中国电机工程学报, 2008, 28(27): 18-22.
[12]  Ribeiro R L A, Jacobina C B, Silva E R C, et al. Fault detection of open-switch damage in voltage-fed PWM motor drive systems[J]. IEEE Transactions on Power Electronics, 2003, 18(2): 587-593.
[13]  Jacobina C B, Ribeiro R L A, Lima A M N, et al. Fault-tolerant reversible AC motor drive system[J]. IEEE Transactions on Industry Applications, 2003, 39(4): 1077-1084.
[14]  Kwak S, Kim T. Fault detection and location of open-circuited switch faults in matrix converter drive systems[C]. Proceedings of the IEEE Vehicle Power and Propulsion Conference, Dearborn, MI, USA, 2009: 1476-1481.
[15]  安群涛, 孙力, 赵克, 等. 基于开关函数模型的逆变器开路故障诊断方法[J]. 中国电机工程学报, 2010, 30(6): 1-6.
[16]  Rothenhagen K, Fuchs F W. Performance of diagnosis methods for IGBT open circuit faults in three phase voltage source inverters for ac variable speed drives[C]. Proceedings of the 11th European Conference on Power Electronics and Applications, Dresden, Germany, 2005: 1-10.
[17]  Lu Bin, Santosh K S. A literature review of IGBT fault diagnostic and protection methods for power inverters[J]. IEEE Transactions on Industry Appli- cations, 2009, 45(5): 1770-1777.
[18]  Abrahamsen F, Blaabjerg F, Ries K, et al. Fuse protection of IGBTs against rupture[C]. Proceedings of the Nordic Workshop on Power and Industrial Electronics, Aalborg, Denmark, 2000: 64-68.
[19]  Iov F, Blaabjerg F, Ries K. IGBT fuses in voltage source converters[C]. Proceedings of the PCIM, Chicago, IL, USA, 2001: 267-276.
[20]  Karimi S, Gaillard A, Poure P, et al. FPGA-based real-time power converter failure diagnosis for wind energy conversion systems[J]. IEEE Transactions on Industrial Electronics, 2008, 55(12): 4299-4308.
[21]  Yu O K, Park N J, Hyun D S. A novel fault detection scheme for voltage fed PWM inverter[C]. Proceedings of the IEEE 32nd Annual Conference on Industrial Electronics, Paris, France, 2006: 2654-2659.
[22]  Peuget R, Courtine S, Rognon J P. Fault detection and isolation on a PWM inverter by knowledge-based model[J]. IEEE Transactions on Industry Applications, 1998, 34(6): 1318-1326.
[23]  Sleszynski W, Nieznanski J, Cichowski A. Open- transistor fault diagnostics in voltage-source inverters by analyzing the load currents[J]. IEEE Transactions on Industrial Electronics, 2009, 56(11): 4681-4688.
[24]  Gilreath P, Singh B N. A new centroid based fault detection method for 3-phase inverter-fed induction motors[C]. Proceedings of the IEEE Power Electronics Specialist Conference, Recife, Brazil, 2005: 2663-2669.
[25]  Diallo D, Benbouzid M E H, Hamad D, et al. Fault detection and diagnosis in an induction machine drive-a pattern recognition approach based on Concordia stator mean current vector[J]. IEEE Transactions on Energy Conversion, 2005, 20(3): 512-519.
[26]  Guan Y F, Sun D, He Y K. Mean current vector based on line real-time fault diagnosis for voltage source inverter fed induction motor drives[C]. Proceedings of the IEEE International Electrical Machines and Drives Conference, Antalya, Turkey, 2007: 1114- 1118.
[27]  孙丹, 孟濬, 管宇凡, 等. 基于相空间重构和模糊聚类的永磁同步电机直接转矩控制系统逆变器故障诊断[J]. 中国电机工程学报, 2007, 27(6): 49-53.
[28]  Kral C, Kafka K. Power electronics monitoring for a controlled voltage source inverter drive with induction machines[C]. Proceedings of the IEEE Power Electronics Specialist Conference, Galway, Ireland, 2000: 213-217.
[29]  Charfi F, Sellami F, Al Haddad K. Fault diagnostic in power system using wavelet transforms and neural networks[C]. Proceedings of the IEEE International Symposium on Industrial Electronics, Montreal, Quebec, Canada, 2006: 1143-1148.
[30]  Awadallah M A, Morcos M M. Diagnosis of switch open-circuit fault in PM brushless DC motor drives[C]. Proceedings of the Large Engineering Systems Conference on Power Engineering, Montreal, Quebec, Canada, 2003: 69-73.
[31]  Awadallah M A, Morcos M M. Automatic diagnosis and location of open-switch fault in brushless DC motor drives using wavelets and neuro-fuzzy systems[J]. IEEE Transactions on Energy Conversion, 2003, 21(1): 104-111.
[32]  Mamat M R, Rizon M, Khanniche M S. Fault detection of 3-phase VSI using wavelet-fuzzy algorithm[J]. American Journal of Applied Sciences, 2006, 3(1): 1642-1648.
[33]  Chang G W, Chen S K. An analytical approach for characterizing harmonic and interharmonic currents generated by VSI-fed adjustable speed drives[J]. IEEE Transactions on Power Delivery, 2005, 20(4): 2585-2593.
[34]  Brouji H E, Poure P, Saadate S. A fast reliable fault diagnosis method for fault tolerant shunt three-phase active filter[C]. Proceedings of the IEEE International Symposium on Industrial Electronics, Montreal, Quebec, Canada, 2006: 1688-1693.
[35]  Cruz S M A, Ferreira M, Cardoso A J M. Output error voltages - a first method to detect and locate faults in matrix converters[C]. Proceedings of the 34th Annual Conference of IEEE Industrial Electronics, Orlando, Florida, USA, 2009: 1319-1325.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679