单因子老化中定子线棒等温松弛电流的研究

, PP. 242-248

Keywords: 单因子老化,等温松弛电流,定子线棒试样,绝缘状况

Full-Text   Cite this paper   Add to My Lib

Abstract:

为研究电机定子线棒老化后的绝缘特性,制备了按实际线棒尺寸比例缩小的线棒试样,并对其进行了单独的热、电老化实验,后测量了不同老化程度线棒试样的等温松弛电流,并基于等温松弛理论研究分析了线棒绝缘内的陷阱分布变化。结果表明线棒绝缘在冷热循环老化过程中存在“后固化”的现象,绝缘内陷阱密度先增加后减小;而在电老化过程中,试样绝缘内浅能级陷阱密度增加。根据不同极化过程对等温松弛电流的贡献,建立了定子线棒等温松弛电流的三阶指数衰减模型。研究表明,电机线棒老化的主要表现是环氧树脂和云母之间界面中缺陷的增加,而三指数衰减模型对等温松弛电流数据的拟合结果也足够准确。

References

[1]  Gonon P, Sylvestre A, Teysseyre J, et al. Dielectric properties of epoxy/silica composites used for microlec- tronic packaging, and their dependence on post- curing[J]. Journal of Materials Science: Materials in Electronics, 2001, 12: 81-86.
[2]  Sylvestre A, Ouajji H, Gonon P, et al. Post-curing influence on electrostatic charges deposited on epoxy/ silica composites used for microelectronic packaging [C]. Proceedings of the 7th Electronic Packaging Technology Conference, 2005.
[3]  郝艳捧, 王国利, 闫波, 等. 大电机定子线棒绝缘状态诊断的研究进展[J]. 高电压技术, 2001, 27(1): 4-6, 15. Hao Yanpeng, Wang Guoli, Yan Bo, et al.The review of diagnosis of stator insulation in large electrical machine[J]. High Voltage Engineering, 2001, 27(1): 4-6, 15.
[4]  欧阳本红, 刘丽兵, 江裕熬, 等. 发电机定子绝缘剩余寿命评估参量的选择[J]. 高电压技术, 2005, 31(1): 30-32. Ouyang Benhong, Liu Libing, Jiang Yuao, et al. Selection of evaluation parameters of remaining life of insulation of generator stator[J]. High Voltage Engineering, 2005, 31(1): 30-32.
[5]  Kowalski E L, Robert R, Tomioka J, et al. Study of electrical conduction mechanisms of the natural rubber by isothermal current depolarization[C]. Proceedings of the International Symposium on Electrical Insulating, Kitakyushu, Japan, 2005.
[6]  王亚群, 尹毅, 李旭光, 等. 等温松弛电流用于10kV XPLE电缆寿命评估的方法[J]. 电工技术学报, 2009, 24(9): 33-37, 52. Wang Yaqun, Yin Yi, Li Xuguang, et al. The method of lifetime evaluation on 10kV XLPE cables by isothermal relaxation current[J]. Transactions of China Electrotechnical Society, 2009, 24(9): 33-37, 52.
[7]  Ueyama T, Mori T, Suenaga K, Experiments of power cable diagnosis by using isothermal relaxation current method[C]. IEEE Conference on Condition Monitoring and Diagnosis, Bali, Indonesia, 2012.
[8]  Neagu E R, Marat-Mendes J N. Electric charge transport and trapping in dielectrics deduced from isothermal and non-isothermal measurements[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2004, 11(2): 249-254.
[9]  Carmo Lanca M, Neagu E R, Neagu R M, et al. Space charge studies in LDPE using combined isothermal and non-isothermal current measurements[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2004, 11(1): 25-34.
[10]  Wu Jiandong, Yin Yi, Li Xuguang, et al. The condition assessment system of XPLE cables using isothermal relaxation current technique[C]. Proceedings of the 9th International Conference on Properties and Applica- tions of Dielectric Materials, Harbin, China, 2009.
[11]  郝艳捧, 谢恒堃. 基于热重和红外光谱分析研究大电机定子绝缘中环氧的老化过程[J]. 中国电机工程学报, 2008, 28(13): 15-19. Hao Yanpeng, Xie Hengkun. Degradation behaviour of epoxy in stator insulation based on thermogravimetry and infra-red spectrometry[J]. Proceedings of the CSEE, 2008, 28(13): 15-19.
[12]  Hoff G, Kranz H G. Correlation between return voltage and relaxation current measurements on XLPE medium voltage cables[C]. High Voltage Engineering Sym- posium, 1999: 22-27.
[13]  Beigert M, Kranz H G.Destruction free ageing diagnosis of power cable insulation using the isothermal relaxation current analysis[C]. Conference of the IEEE Interna- tional Symposium on Electrical Insulation, Pittsburgh, USA, 1994.
[14]  张百华, 高乃奎, 马小芹, 等. 基于运行历史的大电机主绝缘老化特性的研究[J]. 中国电机工程学报, 2004, 24(8): 134-137. Zhang Baihua, Gao Naikui, Ma Xiaoqin, et al. Study on the aging characteristics stator winding insulation in large generator based on operating history[J]. Procedings of the CSEE, 2004, 24(8): 134-137.
[15]  Simmons J G, Tam M C. Theory of isothermal currents and the direct determination of trap parameters in semiconductors and insulators containing arbitrary trap distributions[J]. Physical Review B, 1973, 7(8): 3706-3713.
[16]  Hao Yanpeng, Xie Hengkun, Wang Guoli, et al. Assessment of insulation condition of generator stator bars based on velocity of ultrasonic waves[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2003, 10(3): 539-547.
[17]  尹毅, 屠德民, 李明, 等. 用等温电流法研究自由基清除剂的作用机理——聚合物电老化陷阱理论的实验验证[J]. 中国电机工程学报, 2000, 20(3): 13-15, 25. Yin Yi, Tu Demin, Li Ming, et al. Study on the action mechanism of the free radical scavenger with iso- thermal-current-decay method–an experimental verification of trap theory for electrical aging in polymer[J]. Proceedings of the CSEE, 2000, 20(3): 13-15, 25.
[18]  井益水. 大电机主绝缘多因子老化试验系统设计及定子线棒老化性能研究[D]. 哈尔滨: 哈尔滨理工大学, 2011.
[19]  Koch M, Krueger M, Puetter M. Advanced insulation diagnostic by dielectric spectroscopy[C]. Tech Con Asia Pacific, Sydney, Australia, 2009.
[20]  Sheng H F, Birlasekaran S, Cao X L. Diagnosis of power cable insulation using isothermal relaxation current technique[C]. Proceedings of the 6th Interna- tional Conference on Properties and Applications of Dielectric Materials, Xi’an, China, 2000.
[21]  Oyegoke B S. Improved condition assessment of XLPE insulated cables using the isothermal relaxation current technique[C]. Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2006: 477-480.
[22]  Oyegoke B S, Foottit F, Birtwhistle D, et al. Condition assessment of XLPE insulated cables using isothermal relaxation current technique[C]. Proceedings of the IEEE Power Engineering Society General Meeting, 2006: 18-22.